Volume and Flow Measuring Devices

Description

User has deleted their subject information Quiz on Volume and Flow Measuring Devices, created by Deleted user on 19/08/2016.
Deleted user
Quiz by Deleted user, updated more than 1 year ago More Less
LeeAnna Shepherd
Created by LeeAnna Shepherd almost 8 years ago
LeeAnna Shepherd
Copied by LeeAnna Shepherd over 7 years ago
9
0

Resource summary

Question 1

Question
Volume Measuring Spirometers Wedge Bellows Collapsable bellows that folds and unfolds as patient [blank_start]breathes[blank_end] Will [blank_start]lose[blank_end] volume if cracks or holes in bellows Dry Rolling Seal Spirometer Volume Displacement Consists of a [blank_start]piston[blank_end] within a [blank_start]cylinder[blank_end] supported by a rod resting on a frictionless bearings Rod can be attached directly to a potentiometer or recording pen on paper Can be used to assess pre/post bronchodilator changes Water Seal Spirometer Volume Displacement AKA Collins or [blank_start]Steadwell[blank_end] Large bell [blank_start]7[blank_end]-[blank_start]14[blank_end] L, submerged in a column of [blank_start]H2O[blank_end] As pt breathes, bell moves an equally [blank_start]proportional[blank_end] distance Recorded with chain/pulley device connected to kymograph For rebreathing studies: [blank_start]separate[blank_end] hoses and [blank_start]CO2[blank_end] scrubber are needed Calibration: Using 3L syringer, must be accurate - range +- [blank_start]3.5[blank_end]% Leak Test: Filling spirometer to 1/2 volume then applying a [blank_start]weight[blank_end] Flow Cal: using [blank_start]rotameter[blank_end] 2-12 L/sec
Answer
  • breathes
  • lose
  • piston
  • cylinder
  • Steadwell
  • 7
  • 14
  • H2O
  • proportional
  • separate
  • CO2
  • 3.5
  • weight
  • rotameter

Question 2

Question
Flow measuring Devices Peak flow meter Measure peak expiratory flow at [blank_start]bedside[blank_end] Pt inhales maximally then exhales hard and fast through deice PEFR is read directly from [blank_start]scale[blank_end] Factors that affect accuracy - Pt effort, [blank_start]Moisture[blank_end], Debris Turbine Device Wright Respirometer Rotating [blank_start]Vane[blank_end] with gears, flow causes vanes to [blank_start]spin[blank_end] and displays volume Accurate from 3-200 lpm Assure [blank_start]linearity[blank_end] by checking flows with 3L syringe Can become alinear from vane [blank_start]deformation[blank_end], contamination or debris
Answer
  • bedside
  • scale
  • Moisture
  • Vane
  • spin
  • linearity
  • deformation

Question 3

Question
Pneumotach - measures flow and converts to volume display Ultrasonic Pneumotach AKA [blank_start]Vortex[blank_end] Shedding or Transit Time Consists of an emitting and recieving [blank_start]crystal[blank_end] and a lflow tube with struts Number of [blank_start]pulses[blank_end] is proportional to [blank_start]flow[blank_end] Pitot Tube Flow measured by placing a series of small [blank_start]tubes[blank_end] in a flow sensor and connecting to a pressure transducer Condensation and secretions [blank_start]do not[blank_end] affect measurements Thermal Element Contains heated [blank_start]platinum[blank_end] wire or small metal [blank_start]bead[blank_end] that [blank_start]cools[blank_end] as gas flows across. Amount of current needed to maintain tem is [blank_start]proportional[blank_end] to flow Accuracy is affected by gas [blank_start]composition[blank_end] Pressure Differential AKA Fleisch Pneumotach Contains [blank_start]resistive[blank_end] element that causes pressure to drop as gas flows across. Difference in pressure is [blank_start]proportional[blank_end] to flow Commonly used in Body Box Heat is incorporated to reduce [blank_start]condensation[blank_end]
Answer
  • Vortex
  • crystal
  • pulses
  • flow
  • tubes
  • do not
  • platinum
  • bead
  • cools
  • proportional
  • composition
  • resistive
  • proportional
  • condensation

Question 4

Question
CO2/Water Absorbers CO2 Absorbers Sodium [blank_start]Hydroxide[blank_end], NaOH (SodaLime, Soda-Sorb) BaraLyme, Barium Hydroxide Used for [blank_start]rebreathing[blank_end] tests, [blank_start]He[blank_end] Dilution or DLCO RB Replace: When exhausted, when color [blank_start]changes[blank_end], Weekly Produced H20 as a byproduct. Place upstream from H20 [blank_start]absorber[blank_end] Water Absorber Drie-Rite (calcium sulfate, CaSO4) Removes moisture from pt breathes through circuit When CO2 reacts with soda lime it produces H20 Place [blank_start]AFTER[blank_end] co2 absorber and before analyzer
Answer
  • Hydroxide
  • rebreathing
  • He
  • changes
  • absorber
  • AFTER

Question 5

Question
Permapure Tubing ([blank_start]Fafion[blank_end]) Special tubing - conditions gas to equilibrate with [blank_start]ambient[blank_end] humidity Allows for accurate levels in gas samples Valves Directional Valves Allows tech to switch pt into [blank_start]circuit[blank_end] [blank_start]Directs[blank_end] exhaled gas through analyzers.spirometers
Answer
  • Fafion
  • ambient
  • circuit
  • Directs

Question 6

Question
Calibration 3L syringe to check for [blank_start]leaks[blank_end] Volume should be checked at low, med and high [blank_start]flows[blank_end] to assure linerity Rotameter is a good device for [blank_start]reproducible[blank_end] low flows Sine-Wave [blank_start]pump[blank_end]: Biphasic, simulates flows and volumes Automatic Syringe - [blank_start]Computer[blank_end] Controlled motor syringe Explosive [blank_start]decompression[blank_end] device - simulates FVC Alinearity can happen: Contamination, bent vanes, moisture, debris Once volume displacement spirometer is caled it will retain linearity until it develops a [blank_start]leak[blank_end]
Answer
  • leaks
  • flows
  • reproducible
  • pump
  • Computer
  • decompression
  • leak
Show full summary Hide full summary

Similar

Romeo and Juliet essay
Tambo234
Italian: Basics
Selam H
Principles of basic electrical circuits
Vito Martino
Biology -B2
HeidiCrosbie
Biology B1
Phoebe Drew
AQA Biology B2 Unit 2.1 - Cells Tissues and Organs
BeccaElaine
“The knower’s perspective is essential in the pursuit of knowledge.” To what extent do you agree with this statement?
Lucia Rocha Mejia
RadioTelefonia
Adriana Forero
PSBD TEST 1
Mwebaze Green
Repaso Revalida PR 2016
Rodrigo Lopez
1PR101 2.test - Část 14.
Nikola Truong