Zusammenfassung der Ressource
PERFORMANCE
REQUIERMENRT
- Section
AP
- APO.2
- Meeting the performance requierments
- APO.7
- Relevant performance requierments
- AP1.5
- Compliance with all PR #
Anmerkungen:
- Compliance with all performance requierments.
- General
Provisions
- Section
BP
- BP1.1
- During construction & use #
Anmerkungen:
- A building or structure, during construction & use, with appropriate degrees of reliability must...
- BP1.2
- Resistance of material & forms of constr #
Anmerkungen:
- The structural resistance of material & forms of construction must be determiand by using five percentiles of characteristic material properties with appropriate allowance for.....
- BP1.3
- Glass Installation
- BP1.4
- Flood Hazard Area
Anmerkungen:
- A building in a flood hazard area must be designed & constructed, to the degree necessary, to resist flotation, collaps or significante permanate movement resulting from hydrostatic, hydronamic, erosion & scour, winds & other actions during a define event.....
- Structural
Provisions
- Section
CP
- Fire
Resistance
- CP1
- Structural Stability
- CP2
- Avoid Spreed of Fire
- CP3
- Protection from Spreed of Fire
Anmerkungen:
- A building must be protected from the spreed of fire, smoke & allow surficient time to safeley evacuate.
- CP4
- Tenable conditions during evacuation
- CP5
- Concrete external wall
Anmerkungen:
- To avoide an outwards collaps to tilt-up panales or concrete panals in a fire
- CP6
- Avoid spreed of frie
Anmerkungen:
- A building must have elements, which will, to the degree nescesary, avoid the spreed of fire from service equipment.....
- CP7
- Operation of Emergency Equipment
- CP8
- Element to reist spreed of fire
- CP9
- Access Provided
- Section
DP
- Access &
engress
- DP1
- Access
Anmerkungen:
- DP1 Dose not apply to a class 4 building
- DP2
- Moving safely with-in building
- DP3
- Pepole Falling
Anmerkungen:
- Look at the limitations of DP3
- DP4
- Exits
- DP5
- Evacuating Occupants
- DP6
- Path of tralvel
- DP7
- Exit by Lift
- DP8
- Dissability Parking
Anmerkungen:
- DP9
- Inbuilt Communication Systerms
- Section
FP
- Damp &
Weather
Proofing
- FP1.1
- Surface Water RE of 20yrs
- FP1.2
- Surface Water RE of 100yrs
- FP1.3
- Drainage Systems RE 20yrs
- FP1.4
- Roof, External Walls *
Anmerkungen:
- Roofs, External Walls,openings e.g windows & doors must prevent penetration of water.....
- FP1.5
- Ground Moisture
Anmerkungen:
- FP1.6
- Overflow
- FP1.7
- Prevention
- FP2.1
- Suitable Sanitaries
- FP2.2
- Laundering Facillities
- FP2.3
- Facilities Provided
- FP2.4
- Suitable Means
- FP2.5
- Sanitary Compartments
- FP2.6
- Micro-organisam Controle
- FP3
- Room Hight
- FP3.1
- Room Hight
- FP4
- Light & Ventilation
- FP4.1
- Natural Lighting
- FP4.2
- Illuminance
- FP4.3
- Outdoor Air
- FP4.4
- Mechanical Air
- FP4.5
- Contaminated Air
- FP5
- Sound Transmission & Insulation
- FP5.1
- Separating Floors
- FP5.2
- Separating Walls
- FP5.3
- Floor , Sound Insulation
- FP5.4
- Separating Floors
- FP5.5
- Transmission Insulation
- FP5.6
- Sound Insulation
- Section
JP
- Energy
Efficiancy
- JP1
- Appropriate Energy
- JP2
- Left Blank
- JP3
- Heating