Zusammenfassung der Ressource
AC
- Issues
- Loud/Unusual Sounds
- Not Cooling
- No Air Flow
- Frozen Evap Coil
- Dirty Filter
- Clean or Replace
- Dirty Coils
- Clean or Replace
- Fan Motors
- Capacitor
- Fan Motor not working
- Replace and Recheck System
- Replace and Recheck System
- Low Refrigerant
- Melt Ice, check refrigerat level
- Leaking Refrigerant
- Check for leaks
- Restrictions
- Filter Dryer
- Kink in line set
- Clogged Metering Device
- Power
- Disconnected
- Floot Switch
- Open Wire
- Fuses
- High side
- Transform
- Low side
- Thermostat
- Contactor
- Capacitor
- Not Heating
- Moisture
- Loud noises when the compressor is running
- Running Constantly
- Thermostat issues
- Barely Blowing
- Odors
- Hissing Sound
- leaky ducts
- Tape or Replace Duct
- Buzzing Sound
- Electrical Issue
- Locate and Repair
- Banging Sounds
- Loose Component
- Locate and Repair
- Troubleshooting
- Solutions