Zusammenfassung der Ressource
P-Signals
- P-4: Reactor Trip
- Purpose: Protection Grade Signal
- Setpoint: Reactor Trip Breakers Open
- Coincidence: Train associated trip breaker and bypass breaker open or not connected.
- Notes: Performs the following:
- Activates Main Turbine Trip
- Will generate FW Isolation signal if Tave below low Tave setpoint of 564 deg F (processed by SSPS)
- Blocks auto re-actuation of SI after manually resetting SI (processed by SSPS)
- Seals in FW Isolation signal due to SI or HI-HI S/G level (P-14) (processed by
SSPS)
- Arms Steam Dumps to allow operation in Tave mode from Plant Trip Controller
- P-6: SR Rx Trip Block
- Setpoint: > 10E-10 amps
- Coincidence: 1/2 IR
- Notes:
- Allows manual block of SR Hi Flux Trip (2/2 block switches)
- Block switches also de-energize SR Hi Volts
- When <10E-10 amps on 2/2 channels then:
- SR Hi Volts re-energized
- SR trip and Flux doubling protection re-instated (occurs automatically)
- P-7: At Power
- Setpoint: None
- Coincidence: P-10 or P-13 met
- Notes: The following Rx Trips are re-instated with P-7 met (blocked when not met):
- PZR Lo Pressure
- PZR Hi Level
- RCP Undervoltage
- RCP Underfrequency
- Low Flow in 2 RCS Loops
- P-8: 3 Loop Flow
- Setpoint: > 48%
- Coincidence: 2/4 PR Channels
- Notes: Allows Rx trip when low flow condition is sensed
- On 2/3 channels for 1 RCS loop
- Auto blocked when 2/4 channels < 48%
- P-9: Turbine Trip
- Setpoint: > 50%
- Coincidence: 2/4 PR Channels
- Notes: When met, generates RX Trip if Turbine Trip occurs
- Auto blocked when < 50% on 3/4 PR channels
- P-10: Nuclear At Power
- Setpoint: > 10%
- Coincidence: 2/4 PR Channels
- Notes: When met, it performs the following:
- Feeds P-7
- Auto blocks SR Trip and de-energizes SR Hi Volts
- Allows blocking of IR Trip and C-1
- Allows blocking of PR Trip (Low setpoint)
- SR Hi Flux at S/D annunciator and CTMT Evacuation alarm defeated
- Notes: When 3/4 PR channels < 10% the following are auto re-instated:
- IR Trip
- C-1
- PR Trip (Low setpoint)
- Removes permissive to P-7
- P-11: PZR SI Block
- Setpoint: < 1960 psig
- Coincidence: 2/3 PZR Pressure Channels
- Notes: When met allows manual blocking of:
- Low PZR Pressure SI
- Low Steamline Pressure SI, once blocked the Neg Steam Line P Hi Rate is armed
- Notes: Once PZR P > 1960 psig on 2/3 channels then:
- Low PZR SI blocked, Open signal to SI Accum Isol Valves
- Low Steamline P armed, Neg SL P Hi Rate blocked, Open signal to SI Accum Isol Valves
- P-12: Lo-Lo Tave
- Setpoint: 553 deg F
- Coincidence: 2/4 Channels
- Notes: When met:
- Auto closes all steam dump valves
- 3 Cooldown steam dump valves may be opened by bypass switch
- P-13: Turbine At Power
- Setpoint: Turbine PWR > 10% RTP
- Coincidence: 1/2 Turbine Impulse P Channels
- Notes: When met:
- Feeds P-7
- Auto removes signal to P-7 when no longer met
- P-14: S/G Hi-Hi Level
- Purpose: Protection
- Setpoint: 84% (U1) / 81.5% (U2)
- Coincidence: 2/3 detectors on any 1 S/G
- Notes: When met performs the following:
- Trips MFPs
- Trips Main Turbine
- Generates Main FW Isolation signal