TRAVIS CANNING
Quiz von , erstellt am more than 1 year ago

power engineering 3b2 Quiz am 4.12 Heat Exchangers and Cooling Towers, erstellt von TRAVIS CANNING am 01/03/2016.

76
1
0
TRAVIS CANNING
Erstellt von TRAVIS CANNING vor mehr als 8 Jahre
Schließen

4.12 Heat Exchangers and Cooling Towers

Frage 1 von 10

1

Which of the following are True?
1. Kettle reboilers have a large liquid volume
2. Kettle reboilers may use a weir to keep fluid above the tubes
3. It is important not to flood Thermosyphon reboilers.
4. Thermosyphons depend on a difference in fluid density to promote flow.

Wähle eine der folgenden:

  • 1,2,3

  • 1,2,4

  • 1,3,4

  • 2,3,4

  • 1,2,3,4

Erklärung

Frage 2 von 10

1

In a Cooling tower the drift eliminators:

Wähle eine der folgenden:

  • Break the water into thin sheets to increase the surface area

  • Discharge the air at high velocity to minimize re-circulation

  • Induce the flow of air through the cooling section

  • Separate entrained moisture from the air

  • Prevent waves in the reservoir

Erklärung

Frage 3 von 10

1

Which of the following are true for plate heat exchangers?
1. High turbulence helps prevent fouling
2. Heat transfers well through the thin plates
3. Not good for thick fluids
4. They have a low-pressure drop
5. Gasket placement is critical

Wähle eine der folgenden:

  • 1,2,3,4

  • 2,3,4,5

  • 1,3,4,5

  • 1,2,4,5

  • 1,2,3,5

Erklärung

Frage 4 von 10

1

Which of the following are true for feed water heaters?
1. High pressure feedwater heaters are used between the BFP and boiler
2. Low pressure feedwater heaters are used between the hotwell and dearator
3. Turbine extraction steam is commonly used for feedwater heater
4. Feedwater heaters increase cycle efficiency, resulting in lower fuel costs
5. Feed water heaters are not considered pressure vessels

Wähle eine der folgenden:

  • 1,2

  • 1,3

  • 1,4

  • 1,2,3,4

  • 1,2,3

Erklärung

Frage 5 von 10

1

Hairpin exchangers:

Wähle eine der folgenden:

  • Are mainly used when the exchange surface are exceeds 50 m

  • Are easily assembled

  • Are easily cleaned

  • Are used only for low pressures

  • Are rarely used for heat exchange surfaces below 18m2

Erklärung

Frage 6 von 10

1

In one design of shell and tube exchanger, a floating head:

Wähle eine der folgenden:

  • Helps to allow for expansion due to heat

  • Helps the operator to control water hammer

  • Helps the millwright to flare the tubes

  • Can be constructed of plastic

Erklärung

Frage 7 von 10

1

Concentric pipe heat exchangers

Wähle eine der folgenden:

  • Typically use concurrent flows

  • Always use a smooth bore annulus

  • Are bulky

  • Always use consecutive flows

  • Are used for low heat duties

Erklärung

Frage 8 von 10

1

Which of the following are true for overhead aerial condensers?
1. The footprint influences the design choice
2. Air re-circulation is a way to control temperatures in a tube bank
3. Headers or header boxes contain plugs for tube cleaning
4. Freezing of tube bundles is not normally a concern even on cold days
5. The vertical type is only used for steam condensing

Wähle eine der folgenden:

  • 1,2,3

  • 2,3,4

  • 3,4,5

  • 1,3,5

  • 1,2,3,4,5

Erklärung

Frage 9 von 10

1

The hyperbolic cooling tower has the advantages of:
1. Low initial cost
2. Low power consumption
3. Dependability
4. Minimum maintenance

Wähle eine der folgenden:

  • 1,2,3

  • 2,3,4

  • 1,3,4

  • 1,2,4

  • 1,2,3,4

Erklärung

Frage 10 von 10

1

Which of the following are true for aerial heat exchangers?
1. A bay may have on or more tube bundles
2. A unit may have one or more bays
3. A bank may have on or more units
4. Temperature control may be attained by stop start or variable speed fans.
5. Cleaning the outside of coils is a regular maintenance chore.

Wähle eine der folgenden:

  • 1,2,3

  • 2,3

  • 2,3,4

  • 2,4,5

  • 1,2,3,4,5

Erklärung