Frage 1
Frage
A heating circuit in which the flow and return pipes are completely separated until they connect to the boiler is known as a
Antworten
-
a) one pipe system
-
b) two pipe system
-
c) sealed system
-
d) gravity system.
Frage 2
Frage
A British Standard that includes detail on the requirements for installing open vented central heating systems in dwellings is
Antworten
-
a) BS EN 12056
-
b) BS 6700
-
c) BS EN 12828
-
d) BS 5449.
Frage 3
Frage
Which pipe connects to port X in the diagram of an air separator below?
Frage 4
Frage
What is the recommended actual capacity of the feed and expansion cistern
in a small open vented indirect central heating system?
Antworten
-
a) 6 litres
-
b) 18 litres
-
c) 52 litres
-
d) 100 litres.
Frage 5
Frage
What is the name of the component shown below?
Antworten
-
a) Temperature relief valve.
-
b) Pressure relief valve.
-
c) Pressure regulating valve.
-
d) Thermostatic radiator valve.
Frage 6
Frage
Which one of the following gas boilers overcomes the need for a cold water
storage cistern, feed and expansion cistern and hot water storage vessel?
Antworten
-
a) Back-boiler.
-
b) Traditional.
-
c) Combination.
-
d) Room-heater.
Frage 7
Frage
What is the recommended maximum clip spacing distance for a vertical 15 mm copper pipe?
Antworten
-
a) 1200 mm.
-
b) 1800 mm.
-
c) 2000 mm.
-
d) 2500 mm.
Frage 8
Frage
The Domestic Heating Compliance Guide supports which document?
Antworten
-
a) British Standard 8000.
-
b) The Water Supply (Water Fittings) Regulations.
-
c) British Standard 5449.
-
d) Building Regulations Approved Document L1.
Frage 9
Frage
Minimum controls which must be provided when replacing a gravity fed cylinder supplied from a gas boiler, as laid down in the Domestic Heating Compliance Guide, is
Antworten
-
a) a thermo-mechanical thermostat
-
b) no minimum control required
-
c) fully motorised two port valve
-
d) electronic thermostat.
Frage 10
Frage
What type of heat emitter is shown in the following photograph?
Antworten
-
a)Hospital radiator.
-
b) Panel radiator.
-
c) Column radiator.
-
d) Skirting heater.
Frage 11
Frage
The drawing below shows the connection arrangements to a feed and expansion cistern, pump, open vent and cold feed pipe. What is the likely outcome of positioning the system in the left shown?
Antworten
-
a) The cold feed pipe is at the point of highest positive pressure.
-
b) The system will be largely under negative pressure.
-
c) A neutral pressure will be maintained in all system pipework.
-
d) The system will pump over the open vent pipe.
Frage 12
Frage
The minimum size of the cold feed pipe to a fully pumped heating system in a domestic dwelling is
Antworten
-
a) 15 mm
-
b) 22 mm
-
c) 28 mm
-
d) 35 mm.
Frage 13
Frage
A three-port mid-position valve can provide heated water to
Antworten
-
a) only the heating circuit
-
b) only the hot water circuit
-
c) both the heating and hot water circuit, but not both together
-
d) both the heating or hot water circuit and both together.
Frage 14
Frage
What type of central heating control component is normally used in conjunction with a frost thermostat to conserve energy when exposed parts of a central heating system are required to be protected against frost damage?
Frage 15
Frage
Water in a wet central heating system is normally treated with
Antworten
-
a) sodium hypochlorite
-
b) corrosion inhibitor
-
c) caustic soda solution
-
d) disinfectant.
Frage 16
Frage
What type of central heating component is shown in the photograph below?
Antworten
-
a) Programmer.
-
b) Timer.
-
c) Motorised valve.
-
d) Room thermostat.
Frage 17
Frage
The method by which panel radiators transmit most of their heat is
Antworten
-
a) conduction
-
b) convection
-
c) radiation
-
d) condensation.
Frage 18
Frage
The water level in the feed and expansion cistern of a central heating system should be set to allow sufficient room for
Antworten
-
a) thermal expansion of the water
-
b) coping with pumping over
-
c) air venting
-
d) reduction of noise when filling.
Frage 19
Frage
The normal position for a cylinder thermostat that is strapped to a cylinder is approximately
Antworten
-
a) at the top of the cylinder
-
b) a third of the way down the cylinder from the top
-
c) half way down the cylinder
-
d) a third of the way up from the bottom of the cylinder.
Frage 20
Frage
The type of heating system that uses 2 x two port motorised valves is known as a
Antworten
-
a) A thermostatic radiator valve.
-
b) A lockshield type valve.
-
c) A wheelhead type valve.
-
d) An electro mechanical valve.
Frage 21
Frage
Which component is used in a heating system fitted with a low water content boiler to ensure that a minimum water flow rate is maintained through the boiler heat exchanger at all times?
Antworten
-
a) Automatic bypass valve.
-
b) Pressure relief valve.
-
c) Pressure reducing valve.
-
d) Lockshield gate valve.
Frage 22
Frage
A central heating control component which can regulate the on/off periods of two or more zones in a system is known as a
Antworten
-
frost thermostat
-
room thermostat
-
thermo-mechanical valve
-
programmer.
Frage 23
Frage
Before you carry out a hydraulic pressure test on a new central heating system you should perform
Antworten
-
a) a full disinfection of the system
-
b) a hot flush of the system and add corrosion inhibitor
-
c) a visual inspection of the system
-
d) a heat loss calculation of the system.
Frage 24
Frage
The following diagram shows the actions of which component in a heating system?
Antworten
-
a) Boiler fan.
-
b) Circulating pump.
-
c) Shower pump.
-
d) Diverter valve.