Frage 1

Frage
A heating circuit in which the flow and return pipes are completely separated until they connect to the boiler is known as a
Antworten
  • a) one pipe system
  • b) two pipe system
  • c) sealed system
  • d) gravity system.

Frage 2

Frage
A British Standard that includes detail on the requirements for installing open vented central heating systems in dwellings is
Antworten
  • a) BS EN 12056
  • b) BS 6700
  • c) BS EN 12828
  • d) BS 5449.

Frage 3

Frage
Which pipe connects to port X in the diagram of an air separator below?
Antworten
  • a) Open vent pipe.
  • b) Primary flow to system.
  • c) Primary flow from boiler.
  • d) Cold feed pipe.

Frage 4

Frage
What is the recommended actual capacity of the feed and expansion cistern in a small open vented indirect central heating system?
Antworten
  • a) 6 litres
  • b) 18 litres
  • c) 52 litres
  • d) 100 litres.

Frage 5

Frage
What is the name of the component shown below?
Antworten
  • a) Temperature relief valve.
  • b) Pressure relief valve.
  • c) Pressure regulating valve.
  • d) Thermostatic radiator valve.

Frage 6

Frage
Which one of the following gas boilers overcomes the need for a cold water storage cistern, feed and expansion cistern and hot water storage vessel?
Antworten
  • a) Back-boiler.
  • b) Traditional.
  • c) Combination.
  • d) Room-heater.

Frage 7

Frage
What is the recommended maximum clip spacing distance for a vertical 15 mm copper pipe?
Antworten
  • a) 1200 mm.
  • b) 1800 mm.
  • c) 2000 mm.
  • d) 2500 mm.

Frage 8

Frage
The Domestic Heating Compliance Guide supports which document?
Antworten
  • a) British Standard 8000.
  • b) The Water Supply (Water Fittings) Regulations.
  • c) British Standard 5449.
  • d) Building Regulations Approved Document L1.

Frage 9

Frage
Minimum controls which must be provided when replacing a gravity fed cylinder supplied from a gas boiler, as laid down in the Domestic Heating Compliance Guide, is
Antworten
  • a) a thermo-mechanical thermostat
  • b) no minimum control required
  • c) fully motorised two port valve
  • d) electronic thermostat.

Frage 10

Frage
What type of heat emitter is shown in the following photograph?
Antworten
  • a)Hospital radiator.
  • b) Panel radiator.
  • c) Column radiator.
  • d) Skirting heater.

Frage 11

Frage
The drawing below shows the connection arrangements to a feed and expansion cistern, pump, open vent and cold feed pipe. What is the likely outcome of positioning the system in the left shown?
Antworten
  • a) The cold feed pipe is at the point of highest positive pressure.
  • b) The system will be largely under negative pressure.
  • c) A neutral pressure will be maintained in all system pipework.
  • d) The system will pump over the open vent pipe.

Frage 12

Frage
The minimum size of the cold feed pipe to a fully pumped heating system in a domestic dwelling is
Antworten
  • a) 15 mm
  • b) 22 mm
  • c) 28 mm
  • d) 35 mm.

Frage 13

Frage
A three-port mid-position valve can provide heated water to
Antworten
  • a) only the heating circuit
  • b) only the hot water circuit
  • c) both the heating and hot water circuit, but not both together
  • d) both the heating or hot water circuit and both together.

Frage 14

Frage
What type of central heating control component is normally used in conjunction with a frost thermostat to conserve energy when exposed parts of a central heating system are required to be protected against frost damage?
Antworten
  • a) Room thermostat
  • b) Pipe thermostat.
  • c) Automatic bypass valve.
  • d) Frost relief valve.

Frage 15

Frage
Water in a wet central heating system is normally treated with
Antworten
  • a) sodium hypochlorite
  • b) corrosion inhibitor
  • c) caustic soda solution
  • d) disinfectant.

Frage 16

Frage
What type of central heating component is shown in the photograph below?
Antworten
  • a) Programmer.
  • b) Timer.
  • c) Motorised valve.
  • d) Room thermostat.

Frage 17

Frage
The method by which panel radiators transmit most of their heat is
Antworten
  • a) conduction
  • b) convection
  • c) radiation
  • d) condensation.

Frage 18

Frage
The water level in the feed and expansion cistern of a central heating system should be set to allow sufficient room for
Antworten
  • a) thermal expansion of the water
  • b) coping with pumping over
  • c) air venting
  • d) reduction of noise when filling.

Frage 19

Frage
The normal position for a cylinder thermostat that is strapped to a cylinder is approximately
Antworten
  • a) at the top of the cylinder
  • b) a third of the way down the cylinder from the top
  • c) half way down the cylinder
  • d) a third of the way up from the bottom of the cylinder.

Frage 20

Frage
The type of heating system that uses 2 x two port motorised valves is known as a
Antworten
  • a) A thermostatic radiator valve.
  • b) A lockshield type valve.
  • c) A wheelhead type valve.
  • d) An electro mechanical valve.

Frage 21

Frage
Which component is used in a heating system fitted with a low water content boiler to ensure that a minimum water flow rate is maintained through the boiler heat exchanger at all times?
Antworten
  • a) Automatic bypass valve.
  • b) Pressure relief valve.
  • c) Pressure reducing valve.
  • d) Lockshield gate valve.

Frage 22

Frage
A central heating control component which can regulate the on/off periods of two or more zones in a system is known as a
Antworten
  • frost thermostat
  • room thermostat
  • thermo-mechanical valve
  • programmer.

Frage 23

Frage
Before you carry out a hydraulic pressure test on a new central heating system you should perform
Antworten
  • a) a full disinfection of the system
  • b) a hot flush of the system and add corrosion inhibitor
  • c) a visual inspection of the system
  • d) a heat loss calculation of the system.

Frage 24

Frage
The following diagram shows the actions of which component in a heating system?
Antworten
  • a) Boiler fan.
  • b) Circulating pump.
  • c) Shower pump.
  • d) Diverter valve.
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

2. Weltkrieg: 1939-1945
JohannesK
Welten im Kalten Krieg
andri.roth
Kabale und Liebe - Umfangreiche Lernfolien
Laura Overhoff
Modelle sozialer Ungleichheit
saso
Mediation
Antonia C
PR-Öffentlichkeitsarbeit Teil1
Tanja Eder
KPOL-Fragen (sofort überprüfbar)
Tim Schröder
BM6 Fröhlich SS 19
Daniel Martinovic
Onlinequiz zu MS-4.2 kapitel II
Deborah Büscher
Vetie - spez Patho 2019
Johanna Tr
GETH.1.2
Katrin Dolle