Frage 1

Frage
What type of endotracheal tube combines strength with pliability and is resistant to collapse and less irritating to tissues than other types of tubes?
Antworten
  • Red rubber
  • Polyvinyl chloride
  • Silicone
  • Anode

Frage 2

Frage
What purpose does the Murphy’s eye serve on an endotracheal tube?
Antworten
  • Used to monitor cuff inflation
  • Minimizes the risk of patient asphyxiation
  • Used to inflate the cuff
  • Prevents dead space

Frage 3

Frage
If an endotracheal tube is longer than the thoracic inlet, there is:
Antworten
  • an increased risk of mechanical dead space.
  • a risk of fire due to the higher oxygen content.
  • a risk of only one lung being infused with oxygen and anesthetic gas.
  • a risk of increased amount of mucus in the tube.

Frage 4

Frage
Which device is used to maintain an open airway in an anesthetized patient by connecting with the opening of the epiglottis without invading the tracheal lumen?
Antworten
  • Laryngoscope
  • Supraglottic airway device (SAD)
  • Anesthetic mask
  • Induction chamber

Frage 5

Frage
The scavenger system of an anesthetic machine removes which gas from the patient?
Antworten
  • CO2
  • O2
  • N2O
  • N

Frage 6

Frage
Which portion of the anesthetic machine converts the liquid inhalant anesthetic to a usable form for the patient?
Antworten
  • Compressed gas supply
  • Breathing circuit
  • Scavenging system
  • Vaporizer

Frage 7

Frage
The compressed air service delivers three green cylinders to your practice. What type of gas is in these tanks?
Antworten
  • CO2
  • O2
  • N2O
  • Medical air

Frage 8

Frage
An H-tank of oxygen has a psi measurement of 1000. How long can this tank continue to be used at an oxygen flow rate of 1 L/min?
Antworten
  • 25 hr
  • 30 hr
  • 50 hr
  • 110 hr

Frage 9

Frage
At what pressure level should the tank be replaced?
Antworten
  • 1000 psi
  • 700 psi
  • 500 psi
  • 200 psi

Frage 10

Frage
Which of the following devices ensures that the pressure of the gas is at a constant safe operating pressure regardless of the pressure in the tank?
Antworten
  • Pressure-reducing valve
  • Tank pressure gauge
  • Vaporizer
  • Line pressure gauge

Frage 11

Frage
Which of the following devices reduces the pressure of the gas from about 50 to 15 psi, the optimal pressure for entry into the breathing circuit?
Antworten
  • Pressure-reducing valve
  • Flowmeter
  • Vaporizer
  • Line pressure gauge

Frage 12

Frage
How does a flowmeter set below 100 mL/kg/min affect the concentration of anesthetic in the circuit?
Antworten
  • Increases the actual concentration of anesthetic
  • Does not affect the concentration of anesthetic
  • Lowers the actual concentration of anesthetic
  • The flowmeter cannot be set lower than 100 mL/kg/min

Frage 13

Frage
A normal concentration of isoflurane to maintain a premedicated 20-kg dog would be approximately:
Antworten
  • 5%
  • 0.5%
  • 6%
  • 1.5%

Frage 14

Frage
What should be done if a bottle of inhalant anesthetic is accidentally dropped and breaks?
Antworten
  • Mop up the liquid with a wet mop.
  • Mop up the liquid with paper towels.
  • Evacuate the room immediately and allow the room to air out until the liquid is completely evaporated.
  • There is no reason to do anything as the liquid will evaporate.

Frage 15

Frage
You have been asked to manage general anesthesia on a horse. What type of system would be most appropriate?
Antworten
  • Closed rebreathing system
  • Semiclosed rebreathing system
  • Rebreathing system
  • Partial rebreathing system

Frage 16

Frage
Failure to adjust which of the following devices results in a buildup of excess pressure or volume of gases within the circuit and may damage the animal’s lungs?
Antworten
  • Unidirectional valve
  • Pop-off valve
  • Pressure manometer
  • Air intake valve

Frage 17

Frage
The ideal volume of a reservoir bag for a 44-pound dog should be:
Antworten
  • 500 mL.
  • 1 L.
  • 3 L.
  • 5 L.

Frage 18

Frage
During any procedure, the reservoir bag should be approximately how full at peak expiration?
Antworten
  • 10%
  • 20%
  • 50%
  • 75%

Frage 19

Frage
Fresh granules for the carbon dioxide absorber canister will:
Antworten
  • turn purple.
  • crumble with finger pressure.
  • be hard and brittle.
  • be off-white in color.

Frage 20

Frage
How often should the carbon dioxide granules be changed even without color change?
Antworten
  • 3 to 4 hr of use
  • 6 to 8 hr of use
  • 10 to 12 hr of use
  • Only need to be changed if color changes

Frage 21

Frage
Which of the following devices should an anesthetist monitor when squeezing the reservoir bag to determine the pressure being exerted on the animal’s lungs?
Antworten
  • Unidirectional valve
  • Pop-off valve
  • Pressure manometer
  • Air intake valve

Frage 22

Frage
The maximum safe pressure manometer reading for a 15-kg dog would be:
Antworten
  • 2 cm H2O.
  • 10 cm H2O.
  • 20 cm H2O.
  • 40 cm H2O.

Frage 23

Frage
The patient is a 3-kg kitten. What type of system should be used on the anesthetic machine?
Antworten
  • Closed rebreathing system
  • Non-rebreathing system
  • Rebreathing system
  • Partial rebreathing system

Frage 24

Frage
When a 5-kg animal is placed on a Bain Coaxial Circuit, some rebreathing of waste gas will occur unless the oxygen flow is:
Antworten
  • 0.5 to 1 times the RVM.
  • 2 to 3 times the RVM.
  • 4 to 5 times the RVM.
  • 6 to 7 times the RVM.

Frage 25

Frage
An anesthetist needs to rapidly increase the depth of anesthesia on a patient. Which is the best method of doing so?
Antworten
  • Decrease the oxygen flow using the rebreathing system.
  • Increase the vaporizer settings using the rebreathing system.
  • Use a non-rebreathing circuit.
  • Bag the animal with the precision vaporizer set on 1%.

Frage 26

Frage
The VT in most anesthetized patients is:
Antworten
  • 3 mL/kg/min.
  • 5 mL/kg/min.
  • 8 mL/kg/min.
  • 10 mL/kg/min.

Frage 27

Frage
What would be the recommended oxygen flow rate for mask induction of a 25-pound dog?
Antworten
  • 0.5 mL/kg/min
  • 1 mL/kg/min
  • 2.5 mL/kg/min
  • 4 mL/kg/min

Frage 28

Frage
All parts of the anesthesia machine need to be handled carefully, but which part should the technician take extra care to not overtighten?
Antworten
  • Flowmeter
  • The wing nut holding the E-tank in place
  • Line pressure gauge
  • Oxygen flush valve

Frage 29

Frage
Testing the integrity of which part of the anesthetic machine can be achieved by placing the end of a tube in your mouth with a surgical mask in place?
Antworten
  • Flowmeter
  • Unidirectional valve
  • Pop-off valve
  • Vaporizer

Frage 30

Frage
Disinfecting endotracheal tubes with which of the following will not kill all microorganisms and spores?
Antworten
  • Chlorhexidine gluconate
  • Ethylene oxide
  • Autoclaving
  • Gas sterilization
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Basic Immunology Principles
Robyn Hokulani-C
Anatomical terminology - Axial Skeleton
celine_barbiersg
Veterinary Technician 2
Kadii Spurling
Joint pathology
Justin Veazey
General epi flashes
Sno
Pelvic limb cutaneous nerves
jess_k_turner
LAM II study questions
curfman.melissa
Non-Arboviruses
Nicolette Adamson
LAM II FINAL
curfman.melissa
Encephalon
jess_k_turner
VET EPI EXAM GENERAL
Sno