IMFD Fireground Operations

Beschreibung

Quiz am IMFD Fireground Operations, erstellt von tdtomlins am 12/12/2014.
tdtomlins
Quiz von tdtomlins, aktualisiert more than 1 year ago
tdtomlins
Erstellt von tdtomlins vor fast 10 Jahre
24
0

Zusammenfassung der Ressource

Frage 1

Frage
Order of basic steps of offensive IAP
Antworten
  • 1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Second line-backup first, 6) Ensure adequate water supply, 7) Assigned search team(s), 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.
  • 1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Assigned search team(s), 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.
  • 1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Assigned search team(s), 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Establish secondary Search, 10) Adjust plan and reassign, 11), Evaluate progress 12) Overhaul.
  • 1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Assigned search team(s), 5) Coordinated Ventilation, 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.

Frage 2

Frage
Order used to Scan area with TIC to ensure it is safe to enter.
Antworten
  • 1) Examine Floor, 2) Look up at the ceiling, 3) Scan walls from Right to Left 4) Look back
  • 1) Examine Floor, 2) Look up at the ceiling, 3) Look back 4) Scan walls from Right to Left
  • 1) Look up at the ceiling, 2) Examine Floor, 3) Scan walls from Right to Left 4) Look back
  • 1) Check Temperature of Room 2) Look up at the ceiling, 3) Examine Floor, 4) Scan walls from Right to Left 5) Look back

Frage 3

Frage
Early identification and Fire command structure to a concealed space fire can save the structure quickly
Antworten
  • True
  • False

Frage 4

Frage
Attacking a fire from the exterior before entering a structure is not desirable tactic and should never be used
Antworten
  • True
  • False

Frage 5

Frage
When ventilation is being performed on a fire it should have limited exhaust points
Antworten
  • True
  • False

Frage 6

Frage
The primary search should not begin until after the attack line is in place with water on the fire and ventilation has begun
Antworten
  • True
  • False

Frage 7

Frage
All Clear is called by
Antworten
  • As soon as anyone including neighbors and third party advises everyone is out.
  • Only from the primary search team
  • Only after the secondary search team
  • Can be done by first attack line or primary search team

Frage 8

Frage
When multiple injured victims are encountered
Antworten
  • A transport coordinator should be established
  • A Medical Group should be established
  • A Triage group, Treatment group and transportation group supervisors should be established

Frage 9

Frage
The Radio term used to either remove the occupants or not are
Antworten
  • Removing occupants, Defend in place
  • Evacuating the occupants, Defend in place
  • Evacuating the Occupants, Defending the Occupants
  • Removing occupants, Defending the Occupants

Frage 10

Frage
Rescue efforts should be extended in the following order:
Antworten
  • 1) Most severely threatened, 2) Largest number, 3) the remainder of the fire area 4) exposed area
  • 1) Largest number, 2) Most severely threatened, 3) the remainder of the fire area 4) exposed area
  • 1) Most severely threatened, 2) the remainder of the fire area, 3) Largest number 4) exposed area

Frage 11

Frage
Once utilities are secured it should be reported immediately via radio to command
Antworten
  • True
  • False

Frage 12

Frage
You are allowed to pull the meter if you have been trained and the main disconnect is not at the meter
Antworten
  • True
  • False

Frage 13

Frage
Defensive Attack IAP order
Antworten
  • 1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Assigned search team(s), 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.
  • 1) Take Command, 2) Write off property already destroyed, 3) Prioritize property left to be saved, 4) Attach lines should be outside of collapse zones, 5) Direct all necessary streams onto exposures, 6) if no exposures, keep personnel back use large streams,. 7) Provide an adequate water supply, 8) Evaluate actions 9) adjust plan and reassign as needed 10) Engage a secondary search where allowed.
  • 1) Take Command, 2) Write off property already destroyed, 3) Engage a primary search where allowed 4)Prioritize property left to be saved, 5) Attach lines should be outside of collapse zones, 6) Direct all necessary streams onto exposures, 7) if no exposures, keep personnel back use large streams,. 8) Provide an adequate water supply, 9) Evaluate actions 10) adjust plan and reassign as needed, 11) Engage a secondary search where allowed
  • 1) Take Command, 2) Write off property already destroyed, 3) Engage a primary search where allowed 4)Prioritize property left to be saved, 5) Attach lines should be outside of collapse zones, 6) Evaluate actions, 7) if no exposures, keep personnel back use large streams,. 8) Provide an adequate water supply, 9) Direct all necessary streams onto exposures 10) adjust plan and reassign as needed, 11) Engage a secondary search where allowed

Frage 14

Frage
Secondary search is a systematic search for savable victims.
Antworten
  • True
  • False

Frage 15

Frage
Defensive operations where no continuous water supply is immediately available the first line will be directed towards knocking the fire down, with secondary lines taking care of the exposures
Antworten
  • True
  • False

Frage 16

Frage
Aggressive interior attack operations directed toward knocking down the fire, coupled with coordinated ventilation will always eliminate serious safety concerns.
Antworten
  • True
  • False

Frage 17

Frage
When laddering a building how many feet should be above the roof line
Antworten
  • 4-5
  • 2-4
  • 3-5
  • 2-3

Frage 18

Frage
If a working fire is in progress command should have how many additional personnel.
Antworten
  • Three Times
  • Two Times
  • Four times

Frage 19

Frage
If a ranking officers arrives on scene and wants to take command he can do so before getting a status update from present command
Antworten
  • True
  • False

Frage 20

Frage
Status report to transfer command consists of
Antworten
  • 1) Fire location 2) Fire extent, 3) Present strategic goals 4) effectiveness of tactical efforts, 5) Deployment of companies operating & staging
  • 1) Fire location 2) Resources needed, 3) Present strategic goals 4) effectiveness of tactical efforts, 5) Deployment of companies operating & staging
  • 1) Fire location 2) Fire extent, 3) Present strategic goals, 4) Deployment of companies operating & staging 5) resources needed

Frage 21

Frage
level-1 staging involves
Antworten
  • The first 3-4 engines report to scene all others stage short of scene
  • The first 2 engines report to scene 3rd engine stops 1/2 block away and all others stage short of scene
  • The first engines goes to the scene and the 2nd and 3rd engine stops 1/2 block away until further orders and all others stage short of scene

Frage 22

Frage
The initial company on a high rise fire will have
Antworten
  • SCBAs, TIC, high-rise pack, forcible entry tools, extra bottles
  • SCBAs, TIC, high-rise pack, forcible entry tools, extra 50' of hose
  • SCBAs, TIC, high-rise pack, forcible entry tools

Frage 23

Frage
On mid rises when first responding unit uses elevator to respond to 2nd floor below reported fire. Upon exiting elevator they should return the elevator over to manual so it can return to the lobby without any personnel.
Antworten
  • True
  • False

Frage 24

Frage
To report emergencies not related to lost, trapped or injured personnel you should use what terminology over the radio
Antworten
  • May day repeating twice
  • Priority traffic
  • Red Alert

Frage 25

Frage
Fire personnel should maintain how many feet from the downed line shall be implemented
Antworten
  • 50-150
  • 75-100
  • 75-150
  • 50-100

Frage 26

Frage
What Offensive evolution can be used by a first-in engine company into the structure
Antworten
  • Attack team
  • Primary Search
  • ALL

Frage 27

Frage
What does FIT stand for
Antworten
  • Fully Injured temporary
  • Field Incident Technician
  • A person Injured on Temporary duty for Incident command
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Engineer Quiz
Nathan Geier
Firefighting - Insulating sandwich panels
Firefighter0793
La politique - Vocabulaire
Gaelle Bourgeois
Französische Vokabeln und Redewendungen
anna.grillborzer0656
Deutsch Einstufungstest Niveau A1.2
SprachschuleAktiv
Analytische Geometrie
sonnenblume1997
Vokabeltest Italienisch
aaliyah321321
Gesellschaftsdiagnosen Bogner SS15
Yvonne D. Sulzbe
Modelle sozialer Ungleichheit
saso
KFOR Univie (mögliche Prüfungsfragen)
frau planlos
Jour Gesko WS 18/19
Adrienne Tschaudi