Certainteed Self-Test Section 5

Beschreibung

Sales Representative Roofing (Self-Test ) Quiz am Certainteed Self-Test Section 5, erstellt von Connor Sheffield am 20/11/2019.
Connor  Sheffield
Quiz von Connor Sheffield , aktualisiert more than 1 year ago
Connor  Sheffield
Erstellt von Connor Sheffield vor etwa 5 Jahre
7
0

Zusammenfassung der Ressource

Frage 1

Frage
Roofer’ Select shingle underlayment the ASTM D6757 standard and has more resistance to tearing and wrinkling than #15 type underlayment.
Antworten
  • True
  • False

Frage 2

Frage
Typically, when installing water-resistant underlayment, side laps should be at least two inches and end laps at least six inches
Antworten
  • True
  • False

Frage 3

Frage
One reason to use water resistant underlayment is that is part of Class A fire-rated shingle systems.
Antworten
  • True
  • False

Frage 4

Frage
Joint overlaps for DiamondDeck are different than felt and vary by roof slope.
Antworten
  • True
  • False

Frage 5

Frage
WinterGuard HT has more aggressive “tack” than granular or sand-surfaced WinterGuard and can be installed under asphalt shingles tile or metal roofs.
Antworten
  • True
  • False

Frage 6

Frage
Metalayment is a film-surfaced product that meets ASTM D1970 and can only be applied under metal roofs.
Antworten
  • True
  • False

Frage 7

Frage
All shingles applied to a low slope deck require the use of WinterGuard or its equivalent applied over the entire deck.
Antworten
  • True
  • False

Frage 8

Frage
WinterGuard can be installed over the fascia board to protect against ice build-up in gutters.
Antworten
  • True
  • False

Frage 9

Frage
Drip edge may be applied either over or under WinterGuard along the rake.
Antworten
  • True
  • False

Frage 10

Frage
At the eaves, if there is a chance of snow or ice build-up in the gutters, never install drip edge under the WinterGuard.
Antworten
  • True
  • False

Frage 11

Frage
WinterGuard can be applied when the temperature falls below 40 Degrees Fahrenheit.
Antworten
  • True
  • False

Frage 12

Frage
For ice dam protection, WinterGuard must be applied along the eaves and up the roof no less the 24” beyond the interior wall line.
Antworten
  • True
  • False

Frage 13

Frage
When applying Flintlastic SA, you have the option of installing either a 2-ply or 3-ply roof system.
Antworten
  • True
  • False
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Test Building Design Roofing
Martin Jones
Certainteed Self-Test Section 3
Connor Sheffield
Certainteed Self-Test Section 6
Connor Sheffield
Certainteed Self-Test Section 2
Connor Sheffield
Certainteed Self-Test Section 4
Connor Sheffield
06_Aktiengesellschaft (Karteikarten)
Stefan Kurtenbach
Mediengestalter Abschlussprüfung 2015
Jonas Deh
[Geschichte] Nachkriegsdeutschland - Die Stunde null
Marcel Pabst
Machst du auch diese 10 typischen Fehler auf Deutsch?
Dilyana Hunley
Vetie Histopatho 2014
Ann-Kathrin Riedel
Vetie - Lebensmittelkunde 2017
Birte Schulz