PNEUMATIC VAKIFBANK

Beschreibung

B737-678 PNEUMATIC
GlideSlope localizer
Quiz von GlideSlope localizer, aktualisiert more than 1 year ago
GlideSlope localizer
Erstellt von GlideSlope localizer vor mehr als 4 Jahre
446
0

Zusammenfassung der Ressource

Frage 1

Frage
During a master caution light recall the right pack light illuminates?
Antworten
  • Indicating a failure of other the primary or standby pack control
  • Indication the right air conditioning pack is in high flow
  • Indicating the left pack has been selected off and right pack may overloaded

Frage 2

Frage
The off sched descent light illuminates if...?
Antworten
  • The aircraft has climbed selected flight altitude
  • The aircraft has descended before reaching selected flight altitude
  • The aircraft climbed above the selected flight altitude

Frage 3

Frage
The maximum differential pressure for positive relief valve operation is
Antworten
  • 8,95 PSI
  • 8,15 PSI
  • 8 PSI

Frage 4

Frage
Right pack and zone controller consist of a?
Antworten
  • Primary and standby controller for its respective pack
  • Primary controller on
  • Primary controller for its pack and standby controller for the other pack

Frage 5

Frage
İn case of clogging in water seperator in 737-700?
Antworten
  • İndicator disc on the water seperator is in red range
  • Pack light amber illuminates
  • Duct overheat light amber illuminates

Frage 6

Frage
The purpose of the trim air pressure regulating valve is?
Antworten
  • to provide fine adjustment of temperature of cabin zones
  • to regulate the hot air pressure 4 PSI more than the cabin pressure
  • to regulate the mass of air flow at the inlet packs

Frage 7

Frage
What are the conditions for e&e cooling fans operation?
Antworten
  • The respective equipment cooling switch is in the supply/alternate position
  • The recirculation fan switch must be in the OFF position pack high flow
  • Both of pack switches must be off position the recirculation fan switch AUTO

Frage 8

Frage
In Boeing 737-600-700 aircrafts the right pack discharge overheat switch is located in?
Antworten
  • E&e compartment
  • Distribution manifold in the cabin
  • Air condition mix bay

Frage 9

Frage
Boş
Antworten
  • Boş
  • Boşş
  • Boşşş

Frage 10

Frage
The forward cargo compartment is warmed?
Antworten
  • Only when the main outflow valve fully o..
  • At any time when more than 1 PSI difference pressure exist
  • In flight when more than 2,5 PSI difference

Frage 11

Frage
In auto pressurisation mode the cabin difference pressure for the off?
Antworten
  • 0,10 PSI
  • 0,25 PSI
  • 0,125 PSI

Frage 12

Frage
The pressurization system controls airplane with?
Antworten
  • A control panel, two cabin pressure control and two outflow valves
  • A control panel two cabin pressure control and one outflow valves
  • A control panel one cabin pressure control and one outflow valve

Frage 13

Frage
Why does the DUAL BLEED light illuminate?
Antworten
  • When the APU Bleed valve is closed and the Engine bleed switches On
  • When the APU Bleed valve is open and the Engine bleed switches On
  • When the APU Bleed valve is closed and Engine bleed switches Off

Frage 14

Frage
If an OFF SCHED DESCENT light comes on the pressurization system will
Antworten
  • Pressure the cabin back to the take-off airport altitude
  • Return the cabin to the last cruise altitude
  • Reschedule pressurization rate of change

Frage 15

Frage
The FWD DOOR area heater is located in the ?
Antworten
  • On the left outboard side of the nose wheel well
  • Right side of the FWD cargo compartment
  • On the right inboard side of the nose wheel well

Frage 16

Frage
The bleed air duct pressure indicator?
Antworten
  • Requires AC power for operation
  • Operates only when the CDU operating
  • İndicates both temperature and pressure in the duct

Frage 17

Frage
When using the pneumatic air CENT the battery switch?
Antworten
  • Must be on and air conditioning pack sw on
  • Must be on or off when using aircraft air conditioning
  • Must be on a d air conditioning pack switches off

Frage 18

Frage
Where is the receptacle for external compressed air?
Antworten
  • Lower left side of the fuselage
  • Upper right side of the fuselage
  • Lower right side of the fuselage

Frage 19

Frage
The TRIP RESET switch on the -800-900 airconditioning panel will reset the?
Antworten
  • BLEED TRIP OFF, DUCT OVERHEAT and ZONE TEMP lights provided the fault condition has been corrected.
  • DUCT OVERHEAT, PACK and ZONE TEMP lights provided the fault condition has been corrected
  • BLEED TRIP OFF, PACK, ZONE TEMP lights provided the fault condition has been corrected

Frage 20

Frage
What input required of the pilot for pressurization auto control system to function property?
Antworten
  • Cruise altitude and landing altitudfe
  • Cruise altitude and take-off altitude
  • Landing altitude only

Frage 21

Frage
After the overheat lights illuminated during OVERHEAT test?
Antworten
  • Action is required as the resetting of the system on the window heat computer
  • No action is required as the resetting of system automatic
  • The window heat switches must be momentraily positioned to off to rest the system

Frage 22

Frage
When one air conditioning pack switch selected to HIGH?
Antworten
  • Related pack will regulate to LOW FLOW with flap extend
  • Flap selection has no effect on the low flow rate of that pack
  • The operating pack will regulate to high flow only with flaps up

Frage 23

Frage
If the external pressure exceeds the internal pressure the ... will open?
Antworten
  • Overboard exhaust valve
  • Negative pressure relief valve
  • Positive pressure relief valve

Frage 24

Frage
The CONT CAB amber ZONE TEMP light illuminate with recall indicates?
Antworten
  • Primary or Standby pac controller failure
  • Primary pack controller failure
  • Primary and stanby pack controller failure

Frage 25

Frage
The APU will switch into a HIGH FLOW rate then?
Antworten
  • The flaps are down
  • Both engine bleed air switches are selected OFF regardless of flap position
  • The airplane is on ground

Frage 26

Frage
When the Rİght Pack switch OFF and the isolation valve switch is in AUTO, the isolation valve will?
Antworten
  • Open
  • Closed
  • Modulate

Frage 27

Frage
The RH Pack/Zone Temperature controller?
Antworten
  • Controls the flight deck and provides back up control for the aft cabin
  • Controls the flight deck and fwd cabin
  • Controls the fwd cabin and provides backup control for the flight deck

Frage 28

Frage
Burnination of the amber Bleed Trip Off light indicates ... has automatically closed?
Antworten
  • Pressure REgulating and Shut Off valve
  • Isolation valve
  • Apu bleed valve

Frage 29

Frage
The lh pack zone temperature controller?
Antworten
  • Controls the FWD cabin and provides backup control for the aft cabin
  • Controls the FWD cabin and provides backup control for the flight deck
  • Controls the AFT cabin and provides back up control for the flight deck

Frage 30

Frage
Trim Air Modulating Valves are controlled by?
Antworten
  • The pressure controllers for the fine adjustment of temperature
  • The pack controllers for the basic temperature regulation
  • Two pack zone controllers for thefine adjustment of temperature

Frage 31

Frage
With one air conditioning pack sitch selected to high?
Antworten
  • The pack will regulate to LOW FLOW with flap extended
  • Flap sekection has ne effect on the flow rate of that pack
  • The operating pack will reguate o HIGH FLOW only with glaps up

Frage 32

Frage
In 737-700 series aircraft the air mix valve?
Antworten
  • Pneumatically controlled
  • Electrically operated
  • Pneumatically operated, electrically controlled

Frage 33

Frage
When the PACK TRIP OFF (amber) light illuminates in 737-700 aircraft?
Antworten
  • THe hot butterfly of airmix valve opens automatically
  • Flow control and shut off valve closes automatically
  • Low limit valve closes automatically

Frage 34

Frage
In 737-600/700 rh pack discharge overheat switch is located in
Antworten
  • E/E compartment
  • Distribution manifold in the cabin
  • Air condition mix bay

Frage 35

Frage
If the AMBER AUTO FAIL light illuminates on the pressurization panel?
Antworten
  • Positioning the Pressure Mode Selector to alternate will extinguish the AUTO FAIL light
  • It will automatically extinguis when the pressurization controllers reverts the alternate mode
  • Positioning the Pressurization mode selector to alternate will have no effect on the AUTO FAIL light

Frage 36

Frage
The OUT FLOW valve has ?
Antworten
  • Two motores each controlled by a decide cabin pressure controllers
  • Three motors controlled by a CPC
  • Three motors, two automatically one manually controlled

Frage 37

Frage
Which of the following overheat switches or overtemperature sensors detect and overheat condition when a pack light illuminates?
Antworten
  • Compressor discharge overheat switch,ü turbin inlet overheat switch 190F/88c duct overheat switch or duct limit sensor
  • Compressor discharge overheat switch, turbine inlet overheat switch 190f/88c duct overheat switch
  • Compressor discharge overheat switch, turbine inlet overheat switch or pack discharge overheat switch

Frage 38

Frage
The PITOT PROBE HEATERS lights are?
Antworten
  • Amber in color and associated with the system
  • Not associated with the Master Caution
  • Illuminated when heat is being supplied pitot static and probe heaters

Frage 39

Frage
The High Stage Modulating and Shut Off valve?
Antworten
  • Is opened at all times irrespective of 5th stage air pressure output
  • Will open if the 5th stage air pressure is insufficent
  • will open if the APU bleed air pressure is insufficient

Frage 40

Frage
Standby temperature control valve is ?
Antworten
  • Fully controlled PACK/ZONE controller
  • Electrically controlled and operated
  • Either electrically controlled or pneumatically controlled

Frage 41

Frage
Where is the flight compartment 190F/88c duct overheat switch located? (600-700)
Antworten
  • Distribution compartment
  • E/E compartment
  • LH airconditioning compartment

Frage 42

Frage
The cowl ANTI-ICE light is?
Antworten
  • Amber in clour indicating over temp or over pressure
  • Blue colur and when illuminated indicates the engine cowl anti-ice valve is in disagreement with the engine anti-ice switch
  • Amber in colour indicating overpressure only

Frage 43

Frage
For 800/900 what controls the operating of the temperature control system
Antworten
  • The cabin temperature controller only
  • The temperature controller panel and air conditioning bleed air control panel
  • The temperature control panel , the ACAU and PACK/ZONE Temperature Controller

Frage 44

Frage
The maximum external air pressure (ground cart)
Antworten
  • 30 PSI (at 231C)
  • 40 PSI (at 231C)
  • 60 PSI (at 231C)

Frage 45

Frage
A pack Lİght illuminates in flight (without recall)
Antworten
  • The standby pack has failed but the primary control is operational
  • The primary pack has failed but the standby control is operational
  • Both primary and standby pack controls have failed.

Frage 46

Frage
An engine Bleed Trip OFF light will illuminate
Antworten
  • When engine bleed air temperature or pressure exceeds a predetermined limit
  • Only if engine bleed air pressure exceeds a predetermined limit
  • Only if engine bleed air temperature exceeds a predetermined limit

Frage 47

Frage
The wing Anti-ice control valve_
Antworten
  • are DC motor operated
  • are AC motor operated
  • are pneumatically operated

Frage 48

Frage
With ISOLATION VALVE switch AUTO both ENG BLEED sw ON and BOTH Air Cond Pack sw selected AUTO or HIGH?
Antworten
  • The ISOLATION VAlVE will be closed
  • The ISOLATION VAlVE will be opened
  • The ISOLATION VAlVE will be closed when the flaps are extend

Frage 49

Frage
If the ACM compressor discharge overheat switch activated this?
Antworten
  • Commands the RAM AIR system full close
  • Close the PACK FLOW CONT SOV and PACK light on
  • Causes the pack to go to a HIGH FLOW mode of operation

Frage 50

Frage
THe total air temperature probe
Antworten
  • Does not required heating
  • Its electrically heated
  • It is not heated while on ground

Frage 51

Frage
When the pack discharge reaches 250f/121c (overheat) to reset the Air Conditioner sys?
Antworten
  • Push the P5 trip reset switch
  • Select the pack switch to HIGH or AUTO
  • Reset is automatic

Frage 52

Frage
When you use the wing theamal anti-icing system on the ground?
Antworten
  • De-icing fluids are not necessary
  • There is no protection to prevent heating leading edge overheat conditions
  • THe WTAI selenoid bleeds control pressure from the Precooler Control Valve

Frage 53

Frage
Which is feed into WTAI? Pneumatic system
Antworten
  • True
  • False

Frage 54

Frage
Pack'lerin AUTO dan HİGH a geçmesi için? Flaps up
Antworten
  • True
  • False

Frage 55

Frage
Duct temp 88C ? Zone TEMP
Antworten
  • True
  • False

Frage 56

Frage
PRSOV closes when? Pressure is 220 PSI
Antworten
  • True
  • False

Frage 57

Frage
Ground cart supply pressure? 60 PSI
Antworten
  • True
  • False

Frage 58

Frage
Isolation valve operate? AC
Antworten
  • True
  • False

Frage 59

Frage
Compressor 9th stage? High pressure
Antworten
  • True
  • False

Frage 60

Frage
E/E ventilation? Equipment ventilation (cooling)
Antworten
  • True
  • False

Frage 61

Frage
Wiper how does operate? With knob rotary
Antworten
  • True
  • False

Frage 62

Frage
Cabin altitude aural warning when? 10.000 feet
Antworten
  • True
  • False

Frage 63

Frage
Air comes to precooler where? Fan
Antworten
  • True
  • False

Frage 64

Frage
ANTI-ICE Heater test? HEATER sw ON
Antworten
  • True
  • False

Frage 65

Frage
Pack switch positions? OFF-AUTO-HIGH
Antworten
  • True
  • False

Frage 66

Frage
Outflow valve manual controls? OPEN-CLOSE
Antworten
  • True
  • False

Frage 67

Frage
Positive pressure relief valve? 8,95 PSI
Antworten
  • True
  • False

Frage 68

Frage
What is the PACKs purposes? Basic temperature
Antworten
  • True
  • False

Frage 69

Frage
ACAU? 2 ea
Antworten
  • True
  • False

Frage 70

Frage
Window heater? Interchangable
Antworten
  • True
  • False

Frage 71

Frage
OFF SCHED DESCENT LIGHT? Take off airport altitude
Antworten
  • True
  • False

Frage 72

Frage
PITOT heats? 115v ac
Antworten
  • True
  • False

Frage 73

Frage
RAM AIR actuator? 115v ac
Antworten
  • True
  • False

Frage 74

Frage
Wing thermal Anti Ice? Thrust levers more than 60 degree system doesnt operate. Wing Anti Ice ground thermal on switch iki kanat valflerini de kapatır.
Antworten
  • True
  • False

Frage 75

Frage
9th stage 110 PSI ? High stage fully close
Antworten
  • True
  • False

Frage 76

Frage
490 F (254 C) ? PRSOV close
Antworten
  • True
  • False

Frage 77

Frage
Flow control and Shut off valve ? Selenoid A= APU/HIGH flow operation Selenoid B= LOW and HIGH flow Selenoid C= Open close valve
Antworten
  • True
  • False

Frage 78

Frage
Isolation valve position? Auto-Close
Antworten
  • True
  • False

Frage 79

Frage
Cocpit air? LH PACK
Antworten
  • True
  • False

Frage 80

Frage
TAI ? Shows N! indicator- Green
Antworten
  • True
  • False

Frage 81

Frage
Duct pressure indicator? P5 panel
Antworten
  • True
  • False

Frage 82

Frage
PACK light? ACAU
Antworten
  • True
  • False

Frage 83

Frage
Positive relief valve? Pneumatic
Antworten
  • True
  • False

Frage 84

Frage
Recirculation fan? 115v 3 phase
Antworten
  • True
  • False

Frage 85

Frage
Duct temp 88 üstü? ZONE TEMP light
Antworten
  • True
  • False

Frage 86

Frage
LOW LIMIT sensor? Equipment cooling supply and exhaust
Antworten
  • True
  • False

Frage 87

Frage
Packler AUTO da bir Pack HIGH a geçmesi için? Flaps up
Antworten
  • True
  • False

Frage 88

Frage
737-600-700 duct temp 88 C? DUCT OVHT light
Antworten
  • True
  • False

Frage 89

Frage
737-800/900 DUCT TEMP 88C ? ZONE TEMP light
Antworten
  • True
  • False

Frage 90

Frage
Compressor çıkış sıcaklığı 199 C? Pack light yanar
Antworten
  • True
  • False

Frage 91

Frage
PRSOV ne zaman kapalıya gider? Basınç 220 PSI
Antworten
  • True
  • False

Frage 92

Frage
TAI amber light N1? Valve position not agree more than 8 second
Antworten
  • True
  • False

Frage 93

Frage
Cowl Anti-Ice amber light? Overpressure only
Antworten
  • True
  • False

Frage 94

Frage
Cabin altitude pressure switch? Cabin altitude reached 10000
Antworten
  • True
  • False

Frage 95

Frage
Precooler sensor nerede? ENG Strut Duct
Antworten
  • True
  • False

Frage 96

Frage
Ground thermal WTAI Sensor? Downstream of WTAI
Antworten
  • True
  • False

Frage 97

Frage
Door heating system? -Any pack on -Arcraft on air
Antworten
  • True
  • False

Frage 98

Frage
Heat exchanger blokage? RAM DOOR FULL OPEN blue light on
Antworten
  • True
  • False

Frage 99

Frage
Duct pressure transmitter? Air cond bay
Antworten
  • True
  • False

Frage 100

Frage
Flight Compartment? LH PACK
Antworten
  • True
  • False

Frage 101

Frage
During ENG start? PRSOV close
Antworten
  • True
  • False

Frage 102

Frage
Cargo blowout panels? 1 PSI differenatial pressure
Antworten
  • True
  • False

Frage 103

Frage
TRIP RESET? -ZONE TEMP -BLEED TRIP OFF -PACK
Antworten
  • True
  • False

Frage 104

Frage
Overheat Switches? -comp. discharge -turbine inlet switch -pack discharge
Antworten
  • True
  • False

Frage 105

Frage
Trim Air Regulating Shut Off valve? +4 PSI Cabin air
Antworten
  • True
  • False

Frage 106

Frage
Recirculation system? Fuel save
Antworten
  • True
  • False

Frage 107

Frage
Recirculation fans? Ground= LH Recirc. FAN BOTH PACK HIGH FLOW iken çalışmaz diğer tüm şartlarda yerde çalışır. RH Recirc. FAN yerde her zaman çalışır Air= LH Recirc. FAN herhangi PACK HIGH da ise çalışmaz RH Recirc. FAN iki PACK HIGH ise çalışmaz
Antworten
  • True
  • False

Frage 108

Frage
-600/700 Aircodition? 1 CTC 1 ACAU 1 CONTROL PANEL
Antworten
  • True
  • False

Frage 109

Frage
RH PACK ZONE CONTROLLER? -Flight compartment -FWD pass. cabin
Antworten
  • True
  • False

Frage 110

Frage
NGS Shut Off valve? Center Tank Re-Fuel Valve closed
Antworten
  • True
  • False
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

How well do you know GoConqr?
Sarah Egan
Common Technology Terms
Julio Aldine Branch-HCPL
The Aviation Industry
jameskelsall
Robots
dave_lunt2
Construction technology cards
Fred Fulford
IATA Report: The Impact of September 11 2001 on Aviation
Sarah Egan
Airport & Aviation
Sahar Al Mughairi
Aviation Domain Laws and Regulations
Maddi Cullen
South West Airlines.
Lyndah Kiki Jabe