Frage 1
Frage
An image artifact caused by anatomical motion along a gradient is known as what type of artifact
Antworten
-
Ringing
-
Aliasing
-
Volume averaging
-
Phase mismapping
Frage 2
Frage
Another name for phase mismapping artifact is
Antworten
-
Ringing
-
Aliasing
-
Ghosting
-
Truncation
Frage 3
Frage
An example ofphase mismapping artifact is
Frage 4
Frage
An example of aperiodic motion is
Antworten
-
Cardiac motion
-
Flow motion
-
Respiratory motion
-
Peristalsis motion
Frage 5
Frage
Ghosting artifact on an MR image caused by the heart can be decreased by which of the following methods
Antworten
-
Decreasing bandwidth
-
Peripheral compensation
-
Cardiac gating
-
Respiratory compensation
Frage 6
Frage
Motion artifact on an MR image caused by flowing blood or CSF can be decreased by which of the following methods
Antworten
-
Respiratory compensaton
-
Patient education
-
Gradient moment nulling
-
Respiratory gating
Frage 7
Frage
Peripheral gating is a technique used to decrease what type of motion artifact
Antworten
-
CSF pulsation motion
-
Cardiac motion
-
Swallowing
-
Respiratory motion
Frage 8
Frage
A saturation pulse is a technique used to reduce what type of motion artifact
Antworten
-
Blood flow motion
-
Respiratory motion
-
Swallowing motion
-
All of the above
Frage 9
Frage
Phase mismapping artifact always occurs in which direction of the MR image
Frage 10
Frage
Phase mismapping artifact caused by respiratory motion can be decreased by which method
Frage 11
Frage
Gradient moment nulling is most effective in reducing flow related motion in which type of flow
Frage 12
Frage
The artifact that is produced when anatomy that is outside the FOV is mapped within the FOV is known as
Antworten
-
Phase mismapping
-
Aliasing
-
Partial volume averaging
-
Magnetic susceptibility
Frage 13
Frage
Another name for aliasing artifact is
Frage 14
Frage
Wraparound artifact occurs in which direction of an MR image
Frage 15
Frage
Wraparound artifact caused by undersampling of frequencies in the readout direction is known as
Antworten
-
Phase wrap
-
Frequency wrap
-
Gibbs wrap
-
Truncation
Frage 16
Frage
Foldover artifact caused by undersampling of signal in the phase encoding direction is known as
Antworten
-
Phase wrap
-
Frequency wrap
-
Gibbs wrap
-
None of the above
Frage 17
Frage
Aliasing artifact in the frequency direction can be corrected by which of the following methods
Frage 18
Frage
Foldover artifact in the phase direction can be corrected by which of the following methods
Frage 19
Frage
The precessional frequency of hydrogen is influenced by its chemical environment
Frage 20
Frage
In fat, the hydrogen atom is bound with what other type of atom
Antworten
-
Oxygen
-
Nitrogen
-
Helium
-
Carbon
Frage 21
Frage
In water, the hydrogen atom is bound with what other type of atom
Antworten
-
Oxygen
-
Nitrogen
-
Helium
-
Carbon
Frage 22
Frage
The artifact that is caused due to the difference in precessional frequencies between fat and water is called
Antworten
-
Magnetic susceptibility
-
Chemical shift
-
Truncation
-
Aliasing
Frage 23
Frage
In a 1.5 tesla magnet, the difference in the precessional frequency between fat and water is
Antworten
-
250 MHz
-
210 MHz
-
220 Watts
-
220 Hz
Frage 24
Frage
In a 1.0 tesla magnet, the difference in the precessional frequency between fat and water is
Antworten
-
130 MHz
-
147 Hz
-
200 Hz
-
220 Hz
Frage 25
Frage
Chemical shift artifact occurs in which direction of the MR image
Frage 26
Frage
In an MR image, the degree of chemical shift artifact depends upon which parameter
Antworten
-
Receive bandwidth
-
Size of the FOV
-
Magnetic field strength
-
All of the above
Frage 27
Frage
Chemical shift artifact can be minimized by which of the following methods
Frage 28
Frage
The artifact that is caused by the phase differences between fat and water is known as
Antworten
-
Chemical shift
-
Phase wrap
-
Chemical misregistration
-
Ringing
Frage 29
Frage
Chemical misregistration artifact most commonly occurs in which direction of the MR image
Frage 30
Frage
Chemical misregistration artifact is most likely to affect which type of pulse sequence
Antworten
-
Spin echo pulse sequences
-
Inversion recovery pulse sequences
-
Gradient echo pulse sequences
-
None of the above
Frage 31
Frage
Which imaging parameter affects the amount of chemical misregistration that will be seen on an image
Frage 32
Frage
At 1.5 tesla, to reduce chemical misregistration artifact, the TE should be a multiple of what time
Antworten
-
3.1 ms
-
4.2 ms
-
6.6 ms
-
7.3 ms
Frage 33
Frage
At 0.5 tesla, to reduce chemical misregistration artifact, the TE should be a multiple of what time
Antworten
-
3.1 ms
-
4.2 ms
-
6.6 ms
-
7.0 ms
Frage 34
Frage
The time that both fat and water are in phase with each other is known as
Antworten
-
Peroidicity
-
Repetition time
-
Inversion time
-
None of the above
Frage 35
Frage
Another name for truncation artifact is
Frage 36
Frage
The artifact that appears as a low intensity band in areas of high intensity due to undersampling is known as
Antworten
-
Gibbs artifact
-
Truncation artifact
-
Ringing artifact
-
All of the above
Frage 37
Frage
Gibbs artifact can be decreased by ________ the number of phase encoding steps
Frage 38
Frage
Truncation artifact occurs in which direction of the MRl image
Frage 39
Frage
Metal in the patient, in the area that is being scanned, will most likely create what type of artifact
Antworten
-
Foldover artifact
-
Chemical shift artifact
-
Truncation artifact
-
Magnetic susceptability
Frage 40
Frage
Magnetic susceptibility artifact is most prominent in what type of pulse sequence
Antworten
-
Spin echo
-
Inversion recovery
-
Gradient echo
-
None of the above
Frage 41
Frage
Magnetic susceptibility artifact can be used to help diagnose what pathology
Frage 42
Frage
An artifact that is caused by an external radio frequency leak is known as
Antworten
-
Shading artifact
-
Zipper artifact
-
Starring artifact
-
Herringbone
Frage 43
Frage
In clinical MRI, what method is used to prevent external radio frequency from affecting the MRI image
Antworten
-
Copper shielded room
-
Iron shielded magnet
-
Passive shimming
-
None of the above
Frage 44
Frage
The artifact that is produced by overlapping radio frequency pulses in adjacent slices is known as
Frage 45
Frage
The artifact produced by the transfer of spin lattice energy from one slice
to its adjacent slice is known as
Antworten
-
Wraparound artifact
-
Ringing artifact
-
Cross talk artifact
-
Magnetic susceptibility
Frage 46
Frage
Cross excitation artifact can be eliminated by which ofthe following methods
Frage 47
Frage
The technique used to eliminate cross excitation artifact that acquires data in two separate acquisitions from alternating slices is known as
Antworten
-
Aliasing
-
Interleaving
-
Spin warping
-
None of the above
Frage 48
Frage
To decrease the chances of cross excitation there should be at least what percentage of interslice gap
Frage 49
Frage
Cross excitation artifact is less likely to occur with which pulse sequence
Antworten
-
Spin echo, 90 degree flip angle, 10% interslice gap
-
Spin echo, 90 degree flip angle, 50% interslice gap
-
Gradient echo, 15 degree flip angle, 30% interslice gap
-
Dual echo, 90 degree flip angle, 25% interslice gap
Frage 50
Frage
The artifact that is produced when many structures with different signal intensities are averaged together within a pixel is known as
Antworten
-
Cross talk artifact
-
Truncation artifact
-
Partial volume averaging
-
Aliasing artifact
Frage 51
Frage
Volume averaging artifact can be reduced by which of the following methods
Frage 52
Frage
The artifact that is characterized by a loss of signal intensity in one area of an image is known as
Antworten
-
Aliasing artifact
-
Ringing artifact
-
Shading artifact
-
None of the above
Frage 53
Frage
Shading artifact can be caused by what factor(s)
Antworten
-
Inhomogeneity of the external magnetic field
-
Undersampling of phase encoding steps
-
Inhomogeneity of the RF pulse
-
Inhomogeneity of the external magnetic field & Inhomogeneity of the RF pulse
Frage 54
Frage
Data loss due to gradient instability, excessive noise, or tuning errors can cause an artifact with what type of appearance
Antworten
-
Zippering
-
Shading
-
Staring
-
Herringbone
Frage 55
Frage
An artifact caused by faulty receiver attenuation settings during prescan is known as
Antworten
-
Herringbone
-
Shading
-
Data clipping
-
Aliasing
Frage 56
Frage
Figure 6 - 1 displays an example of what type of artifact?
Antworten
-
Aliasing
-
Truncation
-
Foldover
-
Magnetic Susceptibility
Frage 57
Frage
Figure 6-2 displays an example of what type of artifact
Frage 58
Frage
Figure 6-3 displays an example of what type of artifact
Antworten
-
Ringing
-
Phase wrap
-
Chemical shift
-
Cross talk
Frage 59
Frage
Figure 6-4 displays an example of what type of artifact
Antworten
-
Phase mismapping
-
Aliasing
-
Chemical shift
-
Cross excitation
Frage 60
Frage
Figure 6-5 displays an example of what type of artifact
Antworten
-
Truncation
-
Aliasing
-
Cross excitation
-
Chemical shift
Frage 61
Frage
Figure 6-6 displays an example of what type of artifact
Antworten
-
Aliasing
-
Truncation
-
Chemical shift
-
Phase mismapping
Frage 62
Frage
Figure 6-7 displays an example of what type of artifact
Antworten
-
Aliasing
-
Truncation
-
Chemical shift
-
Phase mismapping