Practice Set (6) - Artifacts and Corrections

Beschreibung

Diploma MR Quiz am Practice Set (6) - Artifacts and Corrections, erstellt von S L am 30/01/2016.
S L
Quiz von S L, aktualisiert more than 1 year ago
S L
Erstellt von S L vor fast 9 Jahre
59
1

Zusammenfassung der Ressource

Frage 1

Frage
An image artifact caused by anatomical motion along a gradient is known as what type of artifact
Antworten
  • Ringing
  • Aliasing
  • Volume averaging
  • Phase mismapping

Frage 2

Frage
Another name for phase mismapping artifact is
Antworten
  • Ringing
  • Aliasing
  • Ghosting
  • Truncation

Frage 3

Frage
An example ofphase mismapping artifact is
Antworten
  • Cardiac motion
  • Flow motion
  • Respiratory motion
  • Cardiac motion & Flow motion & Respiratory motion

Frage 4

Frage
An example of aperiodic motion is
Antworten
  • Cardiac motion
  • Flow motion
  • Respiratory motion
  • Peristalsis motion

Frage 5

Frage
Ghosting artifact on an MR image caused by the heart can be decreased by which of the following methods
Antworten
  • Decreasing bandwidth
  • Peripheral compensation
  • Cardiac gating
  • Respiratory compensation

Frage 6

Frage
Motion artifact on an MR image caused by flowing blood or CSF can be decreased by which of the following methods
Antworten
  • Respiratory compensaton
  • Patient education
  • Gradient moment nulling
  • Respiratory gating

Frage 7

Frage
Peripheral gating is a technique used to decrease what type of motion artifact
Antworten
  • CSF pulsation motion
  • Cardiac motion
  • Swallowing
  • Respiratory motion

Frage 8

Frage
A saturation pulse is a technique used to reduce what type of motion artifact
Antworten
  • Blood flow motion
  • Respiratory motion
  • Swallowing motion
  • All of the above

Frage 9

Frage
Phase mismapping artifact always occurs in which direction of the MR image
Antworten
  • Frequency direction
  • Phase direction
  • Slice selection direction
  • Readout direction

Frage 10

Frage
Phase mismapping artifact caused by respiratory motion can be decreased by which method
Antworten
  • Presaturation pulse
  • Swapping phase and frequency direction
  • Respiratory compensation
  • All of the above

Frage 11

Frage
Gradient moment nulling is most effective in reducing flow related motion in which type of flow
Antworten
  • Slow flow
  • Fast flow
  • Inplane flow
  • Slow flow and inplane flow

Frage 12

Frage
The artifact that is produced when anatomy that is outside the FOV is mapped within the FOV is known as
Antworten
  • Phase mismapping
  • Aliasing
  • Partial volume averaging
  • Magnetic susceptibility

Frage 13

Frage
Another name for aliasing artifact is
Antworten
  • Foldover artifact
  • Ringing artifact
  • Wraparound artifact
  • Foldover artifact & Wraparound artifact

Frage 14

Frage
Wraparound artifact occurs in which direction of an MR image
Antworten
  • Phase direction
  • Frequency direction
  • Slice selection direction
  • Phase direction & Frequency direction

Frage 15

Frage
Wraparound artifact caused by undersampling of frequencies in the readout direction is known as
Antworten
  • Phase wrap
  • Frequency wrap
  • Gibbs wrap
  • Truncation

Frage 16

Frage
Foldover artifact caused by undersampling of signal in the phase encoding direction is known as
Antworten
  • Phase wrap
  • Frequency wrap
  • Gibbs wrap
  • None of the above

Frage 17

Frage
Aliasing artifact in the frequency direction can be corrected by which of the following methods
Antworten
  • Decreasing the FOV
  • Increasing the matrix
  • Filtering the frequencies outside the FOV in the phase direction
  • Filtering the frequencies outside the FOV in the frequency direction

Frage 18

Frage
Foldover artifact in the phase direction can be corrected by which of the following methods
Antworten
  • Oversampling the signal outside the FOV
  • Increasing the FOV
  • Using saturation pulses outside the FOV
  • All of the above

Frage 19

Frage
The precessional frequency of hydrogen is influenced by its chemical environment
Antworten
  • True
  • False

Frage 20

Frage
In fat, the hydrogen atom is bound with what other type of atom
Antworten
  • Oxygen
  • Nitrogen
  • Helium
  • Carbon

Frage 21

Frage
In water, the hydrogen atom is bound with what other type of atom
Antworten
  • Oxygen
  • Nitrogen
  • Helium
  • Carbon

Frage 22

Frage
The artifact that is caused due to the difference in precessional frequencies between fat and water is called
Antworten
  • Magnetic susceptibility
  • Chemical shift
  • Truncation
  • Aliasing

Frage 23

Frage
In a 1.5 tesla magnet, the difference in the precessional frequency between fat and water is
Antworten
  • 250 MHz
  • 210 MHz
  • 220 Watts
  • 220 Hz

Frage 24

Frage
In a 1.0 tesla magnet, the difference in the precessional frequency between fat and water is
Antworten
  • 130 MHz
  • 147 Hz
  • 200 Hz
  • 220 Hz

Frage 25

Frage
Chemical shift artifact occurs in which direction of the MR image
Antworten
  • Phase encoding direction
  • Frequency encoding direction
  • Slice selection direction
  • None of the above

Frage 26

Frage
In an MR image, the degree of chemical shift artifact depends upon which parameter
Antworten
  • Receive bandwidth
  • Size of the FOV
  • Magnetic field strength
  • All of the above

Frage 27

Frage
Chemical shift artifact can be minimized by which of the following methods
Antworten
  • Minimizing the FOV
  • Increasing the receive bandwidth
  • Utilizing chemical saturation
  • All of the above

Frage 28

Frage
The artifact that is caused by the phase differences between fat and water is known as
Antworten
  • Chemical shift
  • Phase wrap
  • Chemical misregistration
  • Ringing

Frage 29

Frage
Chemical misregistration artifact most commonly occurs in which direction of the MR image
Antworten
  • Phase encoding direction
  • Frequency encoding direction
  • Slice selection direction
  • None of the above

Frage 30

Frage
Chemical misregistration artifact is most likely to affect which type of pulse sequence
Antworten
  • Spin echo pulse sequences
  • Inversion recovery pulse sequences
  • Gradient echo pulse sequences
  • None of the above

Frage 31

Frage
Which imaging parameter affects the amount of chemical misregistration that will be seen on an image
Antworten
  • TR
  • TI
  • TE
  • NEX

Frage 32

Frage
At 1.5 tesla, to reduce chemical misregistration artifact, the TE should be a multiple of what time
Antworten
  • 3.1 ms
  • 4.2 ms
  • 6.6 ms
  • 7.3 ms

Frage 33

Frage
At 0.5 tesla, to reduce chemical misregistration artifact, the TE should be a multiple of what time
Antworten
  • 3.1 ms
  • 4.2 ms
  • 6.6 ms
  • 7.0 ms

Frage 34

Frage
The time that both fat and water are in phase with each other is known as
Antworten
  • Peroidicity
  • Repetition time
  • Inversion time
  • None of the above

Frage 35

Frage
Another name for truncation artifact is
Antworten
  • Foldover artifact
  • Gibbs artifact
  • Ringing artifact
  • Gibbs artifact & Ringing artifact

Frage 36

Frage
The artifact that appears as a low intensity band in areas of high intensity due to undersampling is known as
Antworten
  • Gibbs artifact
  • Truncation artifact
  • Ringing artifact
  • All of the above

Frage 37

Frage
Gibbs artifact can be decreased by ________ the number of phase encoding steps
Antworten
  • Increasing
  • Decreasing

Frage 38

Frage
Truncation artifact occurs in which direction of the MRl image
Antworten
  • Phase encoding direction
  • Frequency encoding direction
  • Slice selection direction
  • None of the above

Frage 39

Frage
Metal in the patient, in the area that is being scanned, will most likely create what type of artifact
Antworten
  • Foldover artifact
  • Chemical shift artifact
  • Truncation artifact
  • Magnetic susceptability

Frage 40

Frage
Magnetic susceptibility artifact is most prominent in what type of pulse sequence
Antworten
  • Spin echo
  • Inversion recovery
  • Gradient echo
  • None of the above

Frage 41

Frage
Magnetic susceptibility artifact can be used to help diagnose what pathology
Antworten
  • Torn meniscus
  • Herniated nucleus pulposis
  • Pituitary adenoma
  • Hemorrhage

Frage 42

Frage
An artifact that is caused by an external radio frequency leak is known as
Antworten
  • Shading artifact
  • Zipper artifact
  • Starring artifact
  • Herringbone

Frage 43

Frage
In clinical MRI, what method is used to prevent external radio frequency from affecting the MRI image
Antworten
  • Copper shielded room
  • Iron shielded magnet
  • Passive shimming
  • None of the above

Frage 44

Frage
The artifact that is produced by overlapping radio frequency pulses in adjacent slices is known as
Antworten
  • Cross excitation artifact
  • Aliasing artifact
  • Truncation artifact
  • Phase mismapping artifact

Frage 45

Frage
The artifact produced by the transfer of spin lattice energy from one slice to its adjacent slice is known as
Antworten
  • Wraparound artifact
  • Ringing artifact
  • Cross talk artifact
  • Magnetic susceptibility

Frage 46

Frage
Cross excitation artifact can be eliminated by which ofthe following methods
Antworten
  • Increasing interslice gap
  • Using a sine RF pulse
  • Interleaving
  • All of the above

Frage 47

Frage
The technique used to eliminate cross excitation artifact that acquires data in two separate acquisitions from alternating slices is known as
Antworten
  • Aliasing
  • Interleaving
  • Spin warping
  • None of the above

Frage 48

Frage
To decrease the chances of cross excitation there should be at least what percentage of interslice gap
Antworten
  • 10 %
  • 15 %
  • 30 %
  • 50 %

Frage 49

Frage
Cross excitation artifact is less likely to occur with which pulse sequence
Antworten
  • Spin echo, 90 degree flip angle, 10% interslice gap
  • Spin echo, 90 degree flip angle, 50% interslice gap
  • Gradient echo, 15 degree flip angle, 30% interslice gap
  • Dual echo, 90 degree flip angle, 25% interslice gap

Frage 50

Frage
The artifact that is produced when many structures with different signal intensities are averaged together within a pixel is known as
Antworten
  • Cross talk artifact
  • Truncation artifact
  • Partial volume averaging
  • Aliasing artifact

Frage 51

Frage
Volume averaging artifact can be reduced by which of the following methods
Antworten
  • Increasing slice thickness
  • Decreasing slice thickness
  • Increasing NEX
  • Decreasing NEX

Frage 52

Frage
The artifact that is characterized by a loss of signal intensity in one area of an image is known as
Antworten
  • Aliasing artifact
  • Ringing artifact
  • Shading artifact
  • None of the above

Frage 53

Frage
Shading artifact can be caused by what factor(s)
Antworten
  • Inhomogeneity of the external magnetic field
  • Undersampling of phase encoding steps
  • Inhomogeneity of the RF pulse
  • Inhomogeneity of the external magnetic field & Inhomogeneity of the RF pulse

Frage 54

Frage
Data loss due to gradient instability, excessive noise, or tuning errors can cause an artifact with what type of appearance
Antworten
  • Zippering
  • Shading
  • Staring
  • Herringbone

Frage 55

Frage
An artifact caused by faulty receiver attenuation settings during prescan is known as
Antworten
  • Herringbone
  • Shading
  • Data clipping
  • Aliasing

Frage 56

Frage
Figure 6 - 1 displays an example of what type of artifact?
Antworten
  • Aliasing
  • Truncation
  • Foldover
  • Magnetic Susceptibility

Frage 57

Frage
Figure 6-2 displays an example of what type of artifact
Antworten
  • Magnetic susceptibility
  • Phase wrap
  • RF zipper
  • Magnetic susceptibility & RF zipper

Frage 58

Frage
Figure 6-3 displays an example of what type of artifact
Antworten
  • Ringing
  • Phase wrap
  • Chemical shift
  • Cross talk

Frage 59

Frage
Figure 6-4 displays an example of what type of artifact
Antworten
  • Phase mismapping
  • Aliasing
  • Chemical shift
  • Cross excitation

Frage 60

Frage
Figure 6-5 displays an example of what type of artifact
Antworten
  • Truncation
  • Aliasing
  • Cross excitation
  • Chemical shift

Frage 61

Frage
Figure 6-6 displays an example of what type of artifact
Antworten
  • Aliasing
  • Truncation
  • Chemical shift
  • Phase mismapping

Frage 62

Frage
Figure 6-7 displays an example of what type of artifact
Antworten
  • Aliasing
  • Truncation
  • Chemical shift
  • Phase mismapping
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

AQA (9-1) Topic 3
https:// revisechemistry.uk
9. Mänskliga rättigheter
Louise Prytz
TEXTS IN TIME
caitreble
MSR/MR Strategies
Kerr Smith
cardiovascular-modified-release-designs
jenny schneider
Mr
Sb Rt
Latein Grundwortschatz Vokabeln
anna.grillborzer0656
EC VO Bildungspsychologie und Evaluation
Anna Huber
Grundzüge Soziologie Richter
Kamila rURKA
WT1 Uni Due
Awash Kaul
Vetie Mibi 2012
Tropsi B