Frage 1

Frage
Volume Measuring Spirometers Wedge Bellows Collapsable bellows that folds and unfolds as patient [blank_start]breathes[blank_end] Will [blank_start]lose[blank_end] volume if cracks or holes in bellows Dry Rolling Seal Spirometer Volume Displacement Consists of a [blank_start]piston[blank_end] within a [blank_start]cylinder[blank_end] supported by a rod resting on a frictionless bearings Rod can be attached directly to a potentiometer or recording pen on paper Can be used to assess pre/post bronchodilator changes Water Seal Spirometer Volume Displacement AKA Collins or [blank_start]Steadwell[blank_end] Large bell [blank_start]7[blank_end]-[blank_start]14[blank_end] L, submerged in a column of [blank_start]H2O[blank_end] As pt breathes, bell moves an equally [blank_start]proportional[blank_end] distance Recorded with chain/pulley device connected to kymograph For rebreathing studies: [blank_start]separate[blank_end] hoses and [blank_start]CO2[blank_end] scrubber are needed Calibration: Using 3L syringer, must be accurate - range +- [blank_start]3.5[blank_end]% Leak Test: Filling spirometer to 1/2 volume then applying a [blank_start]weight[blank_end] Flow Cal: using [blank_start]rotameter[blank_end] 2-12 L/sec
Antworten
  • breathes
  • lose
  • piston
  • cylinder
  • Steadwell
  • 7
  • 14
  • H2O
  • proportional
  • separate
  • CO2
  • 3.5
  • weight
  • rotameter

Frage 2

Frage
Flow measuring Devices Peak flow meter Measure peak expiratory flow at [blank_start]bedside[blank_end] Pt inhales maximally then exhales hard and fast through deice PEFR is read directly from [blank_start]scale[blank_end] Factors that affect accuracy - Pt effort, [blank_start]Moisture[blank_end], Debris Turbine Device Wright Respirometer Rotating [blank_start]Vane[blank_end] with gears, flow causes vanes to [blank_start]spin[blank_end] and displays volume Accurate from 3-200 lpm Assure [blank_start]linearity[blank_end] by checking flows with 3L syringe Can become alinear from vane [blank_start]deformation[blank_end], contamination or debris
Antworten
  • bedside
  • scale
  • Moisture
  • Vane
  • spin
  • linearity
  • deformation

Frage 3

Frage
Pneumotach - measures flow and converts to volume display Ultrasonic Pneumotach AKA [blank_start]Vortex[blank_end] Shedding or Transit Time Consists of an emitting and recieving [blank_start]crystal[blank_end] and a lflow tube with struts Number of [blank_start]pulses[blank_end] is proportional to [blank_start]flow[blank_end] Pitot Tube Flow measured by placing a series of small [blank_start]tubes[blank_end] in a flow sensor and connecting to a pressure transducer Condensation and secretions [blank_start]do not[blank_end] affect measurements Thermal Element Contains heated [blank_start]platinum[blank_end] wire or small metal [blank_start]bead[blank_end] that [blank_start]cools[blank_end] as gas flows across. Amount of current needed to maintain tem is [blank_start]proportional[blank_end] to flow Accuracy is affected by gas [blank_start]composition[blank_end] Pressure Differential AKA Fleisch Pneumotach Contains [blank_start]resistive[blank_end] element that causes pressure to drop as gas flows across. Difference in pressure is [blank_start]proportional[blank_end] to flow Commonly used in Body Box Heat is incorporated to reduce [blank_start]condensation[blank_end]
Antworten
  • Vortex
  • crystal
  • pulses
  • flow
  • tubes
  • do not
  • platinum
  • bead
  • cools
  • proportional
  • composition
  • resistive
  • proportional
  • condensation

Frage 4

Frage
CO2/Water Absorbers CO2 Absorbers Sodium [blank_start]Hydroxide[blank_end], NaOH (SodaLime, Soda-Sorb) BaraLyme, Barium Hydroxide Used for [blank_start]rebreathing[blank_end] tests, [blank_start]He[blank_end] Dilution or DLCO RB Replace: When exhausted, when color [blank_start]changes[blank_end], Weekly Produced H20 as a byproduct. Place upstream from H20 [blank_start]absorber[blank_end] Water Absorber Drie-Rite (calcium sulfate, CaSO4) Removes moisture from pt breathes through circuit When CO2 reacts with soda lime it produces H20 Place [blank_start]AFTER[blank_end] co2 absorber and before analyzer
Antworten
  • Hydroxide
  • rebreathing
  • He
  • changes
  • absorber
  • AFTER

Frage 5

Frage
Permapure Tubing ([blank_start]Fafion[blank_end]) Special tubing - conditions gas to equilibrate with [blank_start]ambient[blank_end] humidity Allows for accurate levels in gas samples Valves Directional Valves Allows tech to switch pt into [blank_start]circuit[blank_end] [blank_start]Directs[blank_end] exhaled gas through analyzers.spirometers
Antworten
  • Fafion
  • ambient
  • circuit
  • Directs

Frage 6

Frage
Calibration 3L syringe to check for [blank_start]leaks[blank_end] Volume should be checked at low, med and high [blank_start]flows[blank_end] to assure linerity Rotameter is a good device for [blank_start]reproducible[blank_end] low flows Sine-Wave [blank_start]pump[blank_end]: Biphasic, simulates flows and volumes Automatic Syringe - [blank_start]Computer[blank_end] Controlled motor syringe Explosive [blank_start]decompression[blank_end] device - simulates FVC Alinearity can happen: Contamination, bent vanes, moisture, debris Once volume displacement spirometer is caled it will retain linearity until it develops a [blank_start]leak[blank_end]
Antworten
  • leaks
  • flows
  • reproducible
  • pump
  • Computer
  • decompression
  • leak
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Urlaub und Reisen
JohannesK
Mind Mapping
braun.rachel
Französisch für Anfänger
JohannesK
Themen Geschichte
barbara91
Klausur Thrombose 1.3.3.b
Kevin Kuncic
Grundlagen SAP ERP und SAP NetWeaver
zok42.com
Business-Englisch - Präsentieren
Antonia C
Eriksons Modell psychosexueller und psychosozialer Entwicklung im Kindes-, Jugend- und Erwachsenenalter
Lena S.
Vetie - Pathologie 2016
Fioras Hu
Vetie Pharma Datum unbekannt
Alina Stumpf
Innere Rind Vetie
Anne Käfer