Vet 201 Anesthesiology Chapter Four Study Guide

Question 1 of 30

1

What type of endotracheal tube combines strength with pliability and is resistant to collapse and less irritating to tissues than other types of tubes?

Select one of the following:

  • Red rubber

  • Polyvinyl chloride

  • Silicone

  • Anode

Explanation

Question 2 of 30

1

What purpose does the Murphy’s eye serve on an endotracheal tube?

Select one of the following:

  • Used to monitor cuff inflation

  • Minimizes the risk of patient asphyxiation

  • Used to inflate the cuff

  • Prevents dead space

Explanation

Question 3 of 30

1

If an endotracheal tube is longer than the thoracic inlet, there is:

Select one of the following:

  • an increased risk of mechanical dead space.

  • a risk of fire due to the higher oxygen content.

  • a risk of only one lung being infused with oxygen and anesthetic gas.

  • a risk of increased amount of mucus in the tube.

Explanation

Question 4 of 30

1

Which device is used to maintain an open airway in an anesthetized patient by connecting with the opening of the epiglottis without invading the tracheal lumen?

Select one of the following:

  • Laryngoscope

  • Supraglottic airway device (SAD)

  • Anesthetic mask

  • Induction chamber

Explanation

Question 5 of 30

1

The scavenger system of an anesthetic machine removes which gas from the patient?

Select one of the following:

  • CO2

  • O2

  • N2O

  • N

Explanation

Question 6 of 30

1

Which portion of the anesthetic machine converts the liquid inhalant anesthetic to a usable form for the patient?

Select one of the following:

  • Compressed gas supply

  • Breathing circuit

  • Scavenging system

  • Vaporizer

Explanation

Question 7 of 30

1

The compressed air service delivers three green cylinders to your practice. What type of gas is in these tanks?

Select one of the following:

  • CO2

  • O2

  • N2O

  • Medical air

Explanation

Question 8 of 30

1

An H-tank of oxygen has a psi measurement of 1000. How long can this tank continue to be used at an oxygen flow rate of 1 L/min?

Select one of the following:

  • 25 hr

  • 30 hr

  • 50 hr

  • 110 hr

Explanation

Question 9 of 30

1

At what pressure level should the tank be replaced?

Select one of the following:

  • 1000 psi

  • 700 psi

  • 500 psi

  • 200 psi

Explanation

Question 10 of 30

1

Which of the following devices ensures that the pressure of the gas is at a constant safe operating pressure regardless of the pressure in the tank?

Select one of the following:

  • Pressure-reducing valve

  • Tank pressure gauge

  • Vaporizer

  • Line pressure gauge

Explanation

Question 11 of 30

1

Which of the following devices reduces the pressure of the gas from about 50 to 15 psi, the optimal pressure for entry into the breathing circuit?

Select one of the following:

  • Pressure-reducing valve

  • Flowmeter

  • Vaporizer

  • Line pressure gauge

Explanation

Question 12 of 30

1

How does a flowmeter set below 100 mL/kg/min affect the concentration of anesthetic in the circuit?

Select one of the following:

  • Increases the actual concentration of anesthetic

  • Does not affect the concentration of anesthetic

  • Lowers the actual concentration of anesthetic

  • The flowmeter cannot be set lower than 100 mL/kg/min

Explanation

Question 13 of 30

1

A normal concentration of isoflurane to maintain a premedicated 20-kg dog would be approximately:

Select one of the following:

  • 5%

  • 0.5%

  • 6%

  • 1.5%

Explanation

Question 14 of 30

1

What should be done if a bottle of inhalant anesthetic is accidentally dropped and breaks?

Select one of the following:

  • Mop up the liquid with a wet mop.

  • Mop up the liquid with paper towels.

  • Evacuate the room immediately and allow the room to air out until the liquid is completely evaporated.

  • There is no reason to do anything as the liquid will evaporate.

Explanation

Question 15 of 30

1

You have been asked to manage general anesthesia on a horse. What type of system would be most appropriate?

Select one of the following:

  • Closed rebreathing system

  • Semiclosed rebreathing system

  • Rebreathing system

  • Partial rebreathing system

Explanation

Question 16 of 30

1

Failure to adjust which of the following devices results in a buildup of excess pressure or volume of gases within the circuit and may damage the animal’s lungs?

Select one of the following:

  • Unidirectional valve

  • Pop-off valve

  • Pressure manometer

  • Air intake valve

Explanation

Question 17 of 30

1

The ideal volume of a reservoir bag for a 44-pound dog should be:

Select one of the following:

  • 500 mL.

  • 1 L.

  • 3 L.

  • 5 L.

Explanation

Question 18 of 30

1

During any procedure, the reservoir bag should be approximately how full at peak expiration?

Select one of the following:

  • 10%

  • 20%

  • 50%

  • 75%

Explanation

Question 19 of 30

1

Fresh granules for the carbon dioxide absorber canister will:

Select one of the following:

  • turn purple.

  • crumble with finger pressure.

  • be hard and brittle.

  • be off-white in color.

Explanation

Question 20 of 30

1

How often should the carbon dioxide granules be changed even without color change?

Select one of the following:

  • 3 to 4 hr of use

  • 6 to 8 hr of use

  • 10 to 12 hr of use

  • Only need to be changed if color changes

Explanation

Question 21 of 30

1

Which of the following devices should an anesthetist monitor when squeezing the reservoir bag to determine the pressure being exerted on the animal’s lungs?

Select one of the following:

  • Unidirectional valve

  • Pop-off valve

  • Pressure manometer

  • Air intake valve

Explanation

Question 22 of 30

1

The maximum safe pressure manometer reading for a 15-kg dog would be:

Select one of the following:

  • 2 cm H2O.

  • 10 cm H2O.

  • 20 cm H2O.

  • 40 cm H2O.

Explanation

Question 23 of 30

1

The patient is a 3-kg kitten. What type of system should be used on the anesthetic machine?

Select one of the following:

  • Closed rebreathing system

  • Non-rebreathing system

  • Rebreathing system

  • Partial rebreathing system

Explanation

Question 24 of 30

1

When a 5-kg animal is placed on a Bain Coaxial Circuit, some rebreathing of waste gas will occur unless the oxygen flow is:

Select one of the following:

  • 0.5 to 1 times the RVM.

  • 2 to 3 times the RVM.

  • 4 to 5 times the RVM.

  • 6 to 7 times the RVM.

Explanation

Question 25 of 30

1

An anesthetist needs to rapidly increase the depth of anesthesia on a patient. Which is the best method of doing so?

Select one of the following:

  • Decrease the oxygen flow using the rebreathing system.

  • Increase the vaporizer settings using the rebreathing system.

  • Use a non-rebreathing circuit.

  • Bag the animal with the precision vaporizer set on 1%.

Explanation

Question 26 of 30

1

The VT in most anesthetized patients is:

Select one of the following:

  • 3 mL/kg/min.

  • 5 mL/kg/min.

  • 8 mL/kg/min.

  • 10 mL/kg/min.

Explanation

Question 27 of 30

1

What would be the recommended oxygen flow rate for mask induction of a 25-pound dog?

Select one of the following:

  • 0.5 mL/kg/min

  • 1 mL/kg/min

  • 2.5 mL/kg/min

  • 4 mL/kg/min

Explanation

Question 28 of 30

1

All parts of the anesthesia machine need to be handled carefully, but which part should the technician take extra care to not overtighten?

Select one of the following:

  • Flowmeter

  • The wing nut holding the E-tank in place

  • Line pressure gauge

  • Oxygen flush valve

Explanation

Question 29 of 30

1

Testing the integrity of which part of the anesthetic machine can be achieved by placing the end of a tube in your mouth with a surgical mask in place?

Select one of the following:

  • Flowmeter

  • Unidirectional valve

  • Pop-off valve

  • Vaporizer

Explanation

Question 30 of 30

1

Disinfecting endotracheal tubes with which of the following will not kill all microorganisms and spores?

Select one of the following:

  • Chlorhexidine gluconate

  • Ethylene oxide

  • Autoclaving

  • Gas sterilization

Explanation