What type of pump is used in aviation lube oil systems?
Rotary screw
Air driven
Centrifugal
Rotary vane
What kind of coupling is commonly used in the rotary vane lube oil pump?
Love-joy
Rex-chain
Faulk and grid
Magnetic
What is the capacity of the lube oil storage tank on a CVN class ship?
12,000
6,000
4,000
Varius
What requirement must be adhered to when pumping lube oil to the catapult lube oil ready service tanks?
Maintain constant communication with V-2 personnel
Sample and test lube oil for contaminants
Align the piping so lube oil is routed through the duplex strainers
Both A and C
What are the various methods used to fill the aviation lube oil storage tank?
Transfer from one tank to another
Pour from drums, siphon from drums, transfer from truck
Transfer with MK V!!! pneumatic pumps in tandem
Back drain from catapult ready service tanks
Where is the lube oil fill connection located in most CVN ships?
Hangar deck starboard side
Fantail
Focsle
Hangar deck port side
The lube oil system is composed of what components?
Storage tank and valves
Storage tanks and a pump
Storage tank, one or two pumps, valves and piping
Pump(s), valves, SP phone, and piping
Who is responsible for the alignment of the catapult ready service tanks for each catapult?
A Division
E Divison
V-2 Division
V-4 Division
What types of containers are used on board ships for storing gasoline products?
Plastic cans, 55 gallon drums, rigid portable fuel containers
Glass bottles, rubber bladders, plastic drums
5 gallon metal safety cans, 55 gallon drums, collapsible rubberized fabric drums (bladder), and rigid portable fuel containers
Metal five gallon safety cans, bladders, metal drums only, and semi-rigid portable fuel containers
What is the maximum amount of portable MOGAS required to be carried on board for deployment?
200 gallons
150 gallons
100 gallons
Only enough to support operations requiring the use of MOGAS
Prior to loading MOGAS on board, the integrity of all storage containers (Drums, bladders and rigid cans) shall be _________________?
Logged
Verified
Cleaned
Photographed
A MOGAS warning plate is installed in a conspicuous place or placed near the access to possible hazard areas. The lettering on this placard must be how tall and what color?
1 inch and red letters
1 inch and black letters
2 inch and white letters
2 inch and red letters
All burning or hot work restrictions within __________ feet of MOGAS storage areas and in all directions shall be strictly enofrced
50 feet
75 feet
100 feet
150 yards
What type of fire prevention systems normally located near MOGAS storage areas?
PKP twin agent unit
CO2 fixed system
AFFF sprinkler and hosereel
H20 portable fire bottle
All personnel involved in the operation and movement of MOGAS must be _________?
Qualified for fuel handling
Basic damage control qualified
Petty officers
On restriction for working party
Drums stored horizontally must be removed from the rack prior to filling/receiving gasoline abroad. How are the drums removed?
Crane
Hydraulic fork truck
Using pneumatic tools and pry bar
Manually on to pallets
MOGAS jettison, lockers, and release mechanisms are inspected and maintained IAW what instruction?
PMS
OPNAVINST 5100.19
OPNAVINST 4790.2E
NALCOMIS
What evidence must be provided before any MOGAS bladders are allowed on board ships?
They're gas free
They can hold manufactures suggested quantity
They meet DOT specifications
They have an acceptable evidence of compliance such as a tag stating maintenance was performed on the bladder within the last 12 months
What percentage of gasoline vapor concentration will cause nausea and headache if inhaled for any length of time?
Less than 1%
2-4%
5%
10-15%
What must be done if gasoline gets into a persons eye?
Secure all smoking in the area
Flush eyes with water and seek medical attention immediately
Flush eyes at earliest convenience and if operations allow
Continue with the operation