TRAVIS CANNING
Quiz by , created more than 1 year ago

Quiz on 3.6 Burner Designs and Supply Systems, created by TRAVIS CANNING on 15/01/2016.

16
1
0
No tags specified
TRAVIS CANNING
Created by TRAVIS CANNING almost 9 years ago
Close

3.6 Burner Designs and Supply Systems

Question 1 of 10

1

A low gas pressure cutoff switch ____ the burner from operating when the gas pressure in the supply line drops below the pressure necessary to maintain a stable flame at the burner.

Select one of the following:

  • promotes

  • prevents

  • opens

  • raises

Explanation

Question 2 of 10

1

Reserve storage coal, stocked for extended periods in the open air it will ____ by weathering and also there is an ever-present danger of spontaneous combustion.

Select one of the following:

  • mature

  • vaporize

  • deteriorate

  • solidify

Explanation

Question 3 of 10

1

A spreader stoker distributes the coal onto the surface of a traveling grate with ash discharged at the _____ of the furnace

Select one of the following:

  • back

  • front

  • side

  • bottom

Explanation

Question 4 of 10

1

Screens are fitted in the coal route to the bunkers to remove timber, stone, and oversize coal so that the supply to the ____ mills is kept free

Select one of the following:

  • supply

  • pulverizing

  • storage

  • grading

Explanation

Question 5 of 10

1

The high gas pressure switch contacts are normally _____ whenever the main gas line pressure is below a preset pressure.

Select one of the following:

  • Open

  • stable

  • frozen

  • closed

Explanation

Question 6 of 10

1

An overfeed stoker uses the ______ flow of fuel and air, with fuel flowing downward and air flowing upward.

Select one of the following:

  • cocurrent

  • crosscurrent

  • countercurrent

  • undercurrent

Explanation

Question 7 of 10

1

The heating of heavy fuel oil takes place in ____ stages

Select one of the following:

  • three

  • five

  • many

  • two

Explanation

Question 8 of 10

1

In a _____ stoker, air for combustion is supplied by a forced draft fan an passes up through openings in the grate to the fuel.

Select one of the following:

  • overfeed

  • crossfeed

  • traveling

  • spreader

Explanation

Question 9 of 10

1

The multi-spud burner has ____ spuds or jets connected to a circular manifold.

Select one of the following:

  • two

  • five

  • six

  • eight

Explanation

Question 10 of 10

1

The temperature of the stock should be monitored, because temperatures of ___ deg C and above indicate the threat of fire.

Select one of the following:

  • 100

  • 50

  • 200

  • 70

Explanation