TRAVIS CANNING
Quiz by , created more than 1 year ago

Quiz on 3.8 Boiler Control systems, created by TRAVIS CANNING on 27/01/2016.

26
1
0
No tags specified
TRAVIS CANNING
Created by TRAVIS CANNING almost 9 years ago
Close

3.8 Boiler Control systems

Question 1 of 9

1

A rapid increase in boiler load causes an immediate increase in steam flow from the boiler, which creates a sudden ____ in the boiler steam drum pressure

Select one of the following:

  • drop

  • increase

  • change

  • temperature

Explanation

Question 2 of 9

1

In a fuel flow - airflow combustion control system, the fuel flow signal makes the final adjustment to the ________

Select one of the following:

  • feedwater

  • fuel

  • airflow

  • drum level

Explanation

Question 3 of 9

1

In a fuel flow - airflow combustion control system, the fuel and airflows are measured directly and are converted to ________ signals by means of square root extractors

Select one of the following:

  • digital

  • parallel

  • proportional

  • output

Explanation

Question 4 of 9

1

By measuring and comparing the steam and the _____, it is possible to obtain efficient combustion in a boiler by maintaining a proper steam to airflow ratio

Select one of the following:

  • feedwater

  • fuel

  • airflow

  • drum level

Explanation

Question 5 of 9

1

With On - Off boiler feed water control, water is supplied ______ to the boiler, either by fully opening or fully closing a valve in the feedwater line.

Select one of the following:

  • partially

  • intermittenly

  • fully

  • steadily

Explanation

Question 6 of 9

1

A sudden increase in load, a decrease in drum pressure, and an immediate increase in heat release is called ________

Select one of the following:

  • rate

  • swell

  • shrinkage

  • condensing

Explanation

Question 7 of 9

1

Gas bypass method involves the seperation of the convection section of the boiler into two, or more, ______ gas passes

Select one of the following:

  • reverse

  • crossing

  • parallel

  • counter

Explanation

Question 8 of 9

1

The furnace pressure controller will adjust the boiler ____ dampers to keep the pressure constant at all boiler loads

Select one of the following:

  • outlet

  • inlet

  • air

  • burner

Explanation

Question 9 of 9

1

An oxygen analyzer can also be provided to indicate the excess oxygen in the flue gas, assisting the operator to control the excess air and increasing boiler _________

Select one of the following:

  • load

  • firing

  • temperature

  • efficiency

Explanation