Unit 202: Electrical principles and processes for building

Description

Practice test for unit 202
james crowley
Quiz by james crowley, updated more than 1 year ago
james crowley
Created by james crowley about 7 years ago
4806
4

Resource summary

Question 1

Question
When carrying out a continuity test would you expect:
Answer
  • a. A very high reading
  • b. No reading at all
  • c. A variable reading
  • d. A very low reading.

Question 2

Question
A fault in an electric circuit can be caused by:
Answer
  • a. Low load
  • b. Heavy load
  • c. Over load
  • d. Limited load.

Question 3

Question
Test probes on a multimeter must have a maximum exposed tip of:
Answer
  • a. 1mm
  • b. 2mm
  • c. 3mm
  • d. 4mm.

Question 4

Question
When working on a system that has had a section of pipework removed, which of the following should be used?
Answer
  • a. Permanent polarity bonding
  • b. Permanent earth continuity bonding
  • c. Temporary polarity bonding
  • d. Temporary earth continuity bonding.

Question 5

Question
A radiator fitted near to a shower in a bathroom could require:
Answer
  • a. Supplementary bonding
  • b. Main bonding
  • c. Minor bonding
  • d. Additional bonding.

Question 6

Question
Where is an MCB fitted?
Answer
  • a. Consumer unit
  • b. Outside socket
  • c. Extension lead
  • d. Electric shower.

Question 7

Question
The design, installation and testing of electrical systems is covered by:
Answer
  • a. BS6700
  • b. BS1212
  • c. BS7671
  • d. BS7176.

Question 8

Question
The neutral conductor in fixed-cable installations is identified by the insulation being coloured:
Answer
  • a. Red
  • b. Green/yellow
  • c. Blue
  • d. Brown

Question 9

Question
The relationship between current, resistance and voltage is stated in:
Answer
  • a. Boyle’s law
  • b. Ohm’s law
  • c. Charge’s law
  • d. BS7671.

Question 10

Question
The type of electricity derived from a battery is:
Answer
  • a. Alternating wattage
  • b. Alternating current
  • c. Direct wattage
  • d. Direct current.

Question 11

Question
Calculate the fuse rating for a 690w, 230v AC central heating pump.
Answer
  • a. 13 amp
  • b. 5 amp
  • c. 3 amp
  • d. 1 amp.

Question 12

Question
What is this?
Answer
  • a. Insulation resistance tester
  • b. Digital manometer
  • c. Residual current device tester
  • d. Approved voltage tester.

Question 13

Question
A domestic consumer unit should be installed:
Answer
  • a. Only where there is three phase supply
  • b. Immediately before the supplier’s sealed fuse unit
  • c. On each ring circuit
  • d. Immediately after the supplier’s meter.

Question 14

Question
What is this?
Answer
  • a. Illuminated fused spur
  • b. Double pole pull cord switch
  • c. Single pole rocker plate pull switch
  • d. Wiring centre pull cord.

Question 15

Question
Which one of the following appliances should have its own separate connection to the consumer unit?
Answer
  • a. Immersion heater
  • b. Bathroom light
  • c. Free-standing fan heater
  • d. Gas boiler.

Question 16

Question
A boiler, with a rating of 690watt, 230v, 50Hz has been fitted with a 13 amp fuse. Would you:
Answer
  • a. Leave it as it is
  • b. Change it for a 3 amp fuse
  • c. Fit a 16 amp MCB to protect it
  • d. Warn customer not to touch it.

Question 17

Question
What is this component?
Answer
  • a. 1 gang surface mounted box
  • b. 1 gang counter sunk box
  • c. 2 gang counter sunk box
  • d. 2 gang surface mounted box.

Question 18

Question
Which one of the following could be interrupted by a disconnection of 400v three-phase supply?
Answer
  • a. Heating of domestic hot water via immersion
  • b. Domestic lighting
  • c. Industrial process
  • d. Domestic ring main.

Question 19

Question
The normal voltage for a domestic property is:
Answer
  • a. 415v three phase AC
  • b. 240v single phase DC
  • c. 230v single phase AC
  • d. 110v single phase AC.

Question 20

Question
The flow of electricity through both the live and neutral conductor can be turned off by using:
Answer
  • a. Double pole switch
  • b. Single pole switch
  • c. MCB
  • d. Ring circuit.
Show full summary Hide full summary

Similar

Common Plumbing Principles practice test
james crowley
Unit 205: Cold water systems - practice test
james crowley
Unit 203 Revision Question Bank No.2
Oliver Balay
Unit 201: Health and safety in building services engineering
james crowley
Unit 206: Domestic hot water systems practice test
james crowley
Colour theory quiz
james crowley
Unit 108 Above Ground Drainage
james crowley
Structure of the construction industry
james crowley
Applying paper to walls and ceilings level 1
james crowley
Producing specialist decorative finishes quiz
james crowley
Unit 103 - Environmental and Sustainability Measures in Domestic Dwellings
james crowley