Certainteed Self-Test Section 6

Description

Sales Representative Roofing (Self-Test ) Quiz on Certainteed Self-Test Section 6, created by Connor Sheffield on 20/11/2019.
Connor  Sheffield
Quiz by Connor Sheffield , updated more than 1 year ago
Connor  Sheffield
Created by Connor Sheffield over 4 years ago
6
0

Resource summary

Question 1

Question
The height of the section of step flashing that is applied against a vertical side surface (wall or chimney) must be at least 2” high, but for additional protection, use step flashing with a greater height.
Answer
  • True
  • False

Question 2

Question
It’s okay to fasten the step flashing to cap flashing
Answer
  • True
  • False

Question 3

Question
The base flashing used against a vertical front wall must:
Answer
  • Be a continuous piece of metal up to 10’ in length.
  • Be embedded in asphalt plastic cement.
  • Extend up the wall at least 2”.
  • All of the above.

Question 4

Question
A cricket:
Answer
  • Projects through the roof and should be handled like a round vent pipe.
  • Helps to prevent a build-up of ice and snow at the uppermost side of the chimney.
  • Is put in position after the underlayment has be applied.
  • Is fastened to the deck with asphalt plastic cement.

Question 5

Question
Cap Flashing, continuous counter flashing and surface mounted counter flashing are three flashing methods used on chimneys.
Answer
  • True
  • False

Question 6

Question
Base flashing is required at the point where a dormer meets a sloping roof.
Answer
  • True
  • False

Question 7

Question
When installing a closed-cut valley, first lay the shingles from the roof with lesser area across the valley and on to the adjoining roof area at least 24 inches.
Answer
  • True
  • False

Question 8

Question
Generally, the valley method preferred by Certainteed is the closed-cut method.
Answer
  • True
  • False

Question 9

Question
Open valleys are recommended for Grand Manor, Carriage House, Landmark TL, Presidential Shake, and Presidential TL.
Answer
  • True
  • False

Question 10

Question
The alternate closed valley application is recommended for 3 tab shingles.
Answer
  • True
  • False

Question 11

Question
Flashing a skylight curb requires apron flashing on the base, step flashing on the sides, base flashing on the upslope side, and a kick-out diverter.
Answer
  • True
  • False

Question 12

Question
Hemmed edges on flashing that are turned upward create air gaps that resist the movement of moisture from the metal to the roofing.
Answer
  • True
  • False
Show full summary Hide full summary

Similar

Test Building Design Roofing
Martin Jones
Certainteed Self-Test Section 3
Connor Sheffield
Certainteed Self-Test Section 5
Connor Sheffield
Certainteed Self-Test Section 2
Connor Sheffield
Certainteed Self-Test Section 4
Connor Sheffield
French Intermediate
PatrickNoonan
The First, Second, Third and Fourth Crusades
adam.melling
A level Computing Quiz
Zacchaeus Snape
FCE Practice Quiz - B2
Christine Sang
All AS Maths Equations/Calculations and Questions
natashaaaa
PSBD/PSCOD/ASSD-New
Yuvraj Sunar