Question 1
Question
A worker needs to repair the HVAC in Francis Hall. He goes into the first floor mechanical room to shut off the power to the Air Handler. What will he place on the switch inside of the breaker box after he shuts power off to the system?
Question 2
Question
LOTO can be placed on both Disconnects and Switches inside of Control Panels?
Question 3
Question
How many volts are in OH1 coming to a building?
Question 4
Question
Which unit is a Transformer altering?
Question 5
Question
What does a transformer do?
Question 6
Question
_____ come off of the transformer and go to the building.
Answer
-
OH1
-
OH2
-
Meter
-
Weather Head
Question 7
Question
what is the purpose of a Weather Head?
Answer
-
protects electrical wire from rainwater
-
the point of the conduit where wire sticks out
-
allows electrician protect his head in bad weather when working
-
allows wire to bend
Question 8
Question
what is the purpose of a guy wire?
Answer
-
purely structural, no power going to them.
-
it is a ground wire for the overhead powerlines.
-
it feeds to the underground transformer.
-
it does not do anything.
Question 9
Question
what is the difference between OH 1-phase and OH 3-phase?
Answer
-
Nothing, they are the same.
-
OH 1-phase has 1 transformer and a OH 3-phase has 3 transformers
-
OH 1-phase has 3 transformer and a OH 3-phase has 1 transformers
-
OH 3-phase can only be mounted on concrete poles while OH 1-phase can only be placed on a wooden pole.
Question 10
Question
an OH power line needs to reach a pad mounted transformer underground, however a large light pole is in the way of travel. what electrical device will be installed to fix this issue?
Answer
-
a pull box - able to pull the line from the OH line, then can send wire to the pad mounted transformer.
-
another transformer - able to pull the line from the OH line, then cam send the wire to the pad mounted transformer.
-
a meter - an electrical meter is able to read the power leaving the OH line and sends that information to the transformer.
-
transfer to a single phase OH from a three phase OH
Question 11
Question
what is the difference between a Transformer and a Pull Box?
Question 12
Question
__________ is the pressure in wire.
Question 13
Question
__________ is the flow in wire.
Question 14
Question
volts x amps = __________
Question 15
Question
an unsupervised open transformer is perfectly safe and nothing to worry about
Question 16
Question
what is the purpose of a disconnect switch?
Question 17
Question
an electrician is indoors, in air-conditioned space, pulling wire through a conduit that is threaded. what is wrong with this scenario?
Answer
-
electrician is doing nothing wrong.
-
electrician is pulling wire through an IMC/RMC
-
electrician is pulling wire through EMT
-
electrician is pulling wire through PVC
Question 18
Question
EMT pipe is connected in two ways:
Answer
-
compression
-
set screws
-
threaded
-
cement/glue
Question 19
Question
Thickest pipe wall is _____
Question 20
Question
this conduit is better at taking physical damage, better than EMT at resisting corrosion.
Answer
-
IMC/RMC
-
PVC
-
Copper
-
Aluminum
Question 21
Question
this conduit is BEST at running conduit underground.
Question 22
Question
PVC is great at running conduit above ground
Question 23
Question
EMT Stands for Electrical Metallic Tubing
Question 24
Question
EMT can be ran underground
Question 25
Question
EMT comes in _____ lengths
Question 26
Question
from running conduit outside of the home to inside of the home, what is used to make the transition?
Answer
-
Line Box (LB)
-
Junction Box (J-Box)
-
Flex Conduit
-
Pull Box
Question 27
Question
What is the 360 degree rule?
Answer
-
when four 90 degree bends have been made for conduit, a junction box needs to be placed to reset the degree of bends to 0.
-
You can not twist wire more than 360 degrees when pulling wire.
-
flex conduit is only to be used when wire needs to go around an object
-
you have to have conduit on all four sides of the junction box
Question 28
Question
What is the purpose of a Pull Box?
Answer
-
usually outdoors - acts as a pull point for wire, wire connection protection, and able to change wire direction.
-
need to have it before any transformer.
-
acts the same as a transformer just larger. can be able to handle more voltage.
-
usually indoors - acts as a pull point for wire, wire connection protection, and able to change wire direction.
Question 29
Question
what is the purpose of a junction box?
Answer
-
usually indoors - acts as a pull point for wire, wire connection protection, and able to change wire direction.
-
usually outdoors - acts as a pull point for wire, wire connection protection, and able to change wire direction.
-
Need to have it before any indoor transformer,
-
Replaces the need of flex-conduit.
Question 30
Question
What is the difference between In-Line Metering and CT Metering?
Answer
-
In-Line Metering - the meter and the disconnect box are inline. While CT Metering - the meter and the disconnect box are not inline.
-
In-Line Metering - the meter and the disconnect box are not inline. While CT Metering - the meter and the disconnect box are inline.
-
In-Line Metering - the meter and the disconnect box are inline. While CT Metering - the meter and the disconnect box are inline.
-
In-Line Metering - the meter and the disconnect box are not inline. While CT Metering - the meter and the disconnect box are not inline.
Question 31
Question
the breaker box is the beginning of the circuit
Question 32
Question
what is a switch board?
Answer
-
distributes loads to several smaller load circuits (breaker panels).
-
steps-down voltage from underground to building
-
reduces volts from 12000 to 600
-
board to switch between one-pole, two-pole, and three-pole
Question 33
Question
what are panelboards?
Answer
-
divides electrical power into branch circuits throughout a building.
-
feed power to transformers.
-
feed power to switchboards.
-
1-phase breaker box
Question 34
Question
what is a dead front?
Answer
-
covers the back of a panelboard. covers the wires.
-
a wire that has no charge. dead
-
a load (lightbulb) that has no power going to it.
-
a breaker switch that has been tripped.
Question 35
Question
What is a Main Circuit Breaker (MCB)
Answer
-
A circuit breaker that has a main switch on the dead front allowing to shut off all of the circuits within the breaker at one.
-
a circuit breaker that does not have a main switch on the dead front. have to shut off all of the circuits manually one at a time.
-
the main switch board that gets the power from the transformer.
-
if a building that only has one circuit breaker.
Question 36
Question
What is a Main Lug Only (MLO) breaker
Answer
-
A circuit breaker that has a main switch on the dead front allowing to shut off all of the circuits within the breaker at one.
-
a circuit breaker that does not have a main switch on the dead front. have to shut off all of the circuits manually one at a time.
-
the main switch board that gets the power from the transformer.
-
if a building that only has one circuit breaker.
Question 37
Question
An Electrician is running conduit from the slab to the MCB outside. What conduit will you need to make sure he is installing?
Question 38
Question
there are total of 3 phases. what are they?
Answer
-
1-phase, 3-phase low, 3-phase high.
-
1-phase, 3-phase medium, 3-phase high.
-
1-phase, 2-phase, 3-phase.
-
1-phase low, 1-phase high, 3-phase.
Question 39
Question
1-phase voltage has the combination of __________
Answer
-
120/240
-
120/208
-
277/480
-
110/220
Question 40
Question
3-phase voltage has the combination of __________
Answer
-
120/240
-
120/208
-
277/480
-
110/220
Question 41
Question
3-phase low voltage has the combination of __________
Answer
-
120/240
-
120/208
-
277/480
-
110/220
Question 42
Question
3-phase high voltage has the combination of __________
Answer
-
120/240
-
120/208
-
277/480
-
110/220
Question 43
Question
what is the difference between 1-phase and 3-phase?
Answer
-
1-phase has a 3-wire configuration and a 3-phase has a 4-wire configuration.
-
1-phase uses black, red, and blue as hot wires and 3-phase uses brown, orange (or purple), and yellow as hot wires.
-
1-phase can have 1 and 3 pole configurations while 3-phase can have 1, 2, or 3 poles.
-
1-phase can use either a pole mounted or a on-ground transformer while a 3-phase can only use a ground mounted.
Question 44
Question
3-phase high can use a pole mounted transformer.
Question 45
Question
you see an electrician installing a transformer and is installing wire that is black, red, blue and brown, orange, and yellow. what is happening?
Answer
-
the electrician is setting up an interior 3-phase transformer. going from high to low 3-phase.
-
the electrician is setting up an exterior 3-phase transformer. going from high to low 3-phase.
-
the electrician is setting up an interior 3-phase transformer. going from low to high 3-phase.
-
the electrician is setting up an exterior 3-phase transformer. going from low to high 3-phase.
Question 46
Question
120/240V is the same as 240/120V
Question 47
Question
the feeder is conduit and wire that enters a circuit panel and branches leave the circuit panel providing individual circuits to rooms/appliances.
Question 48
Question
feeders entering the circuit panels have __________
Answer
-
big wires (large amps)
-
small wires (small amps)
-
big wires (small amps)
-
small wires (large amps)
Question 49
Question
flex conduit is also known as metal clad cable
Question 50
Question
amps drive wires size.
small wire = low amps
large wire = high amps
Question 51
Question
which statement is true about the National Electric Code?
Answer
-
for equipment operating at 600 volts, electrical panels must have a minimum of 3 ft.
-
for equipment operating at 800 volts, electrical panels must have a minimum of 4 ft.
-
for equipment operating at 800 volts, electrical panels must have a minimum of 8 ft.
-
for equipment operating at 600 volts, electrical panels must have a minimum of 6 ft.
Question 52
Question
choose which statement is correct.
Answer
-
the NEC requires the area under and above a CB to be only for electrical items only. plumbing and other items are prohibited.
-
the NEC requires the area under a CB to be only for electrical items only. plumbing and other items are prohibited.
-
the NEC requires the area above a CB to be only for electrical items only. plumbing and other items are prohibited.
-
The NEC does not have any statements on whether you need a clear area above or below a CB
Question 53
Question
choose which statement is accurate.
Answer
-
the NEC requires a main disconnect switch if there are more than 6 mini-disconnects outside.
-
the NEC requires a main disconnect switch if there are more than 8 mini-disconnects outside.
-
the NEC requires a main disconnect switch if there are more than 4 mini-disconnects outside.
-
the NEC requires a main disconnect switch if there are more than 10 mini-disconnects outside.
Question 54
Question
There is a heavy storm in town and you're at home with your whining dog, rain and wind come and take your service power out, however, in seven seconds, your power is restored but now you hear a humming noise coming from the side of your house. what just happened?
Answer
-
your Automatic Transfer Switch (ATS) kicked into action and turned on the Generac to keep the house powered until Center Point can get power back on the grid.
-
Center Point lost power but it came back on in seven seconds.
-
Center Point lost power for seven seconds but it came back in seven seconds. The humming is the transformer making noise.
-
your Un-Interruptible Power Supplies (UPS) kicked into action and turned on the Generac to keep the house powered until Center Point can get power back on the grid.
Question 55
Question
Hospitals use this to have no interruption if power goes out. Do not even know power went out.
A room that has batteries that can keep the building powered until an alternate source of energy is supplied to the building like a Generator or the Utility Company gets power back.
Question 56
Question
1-phase systems are known as __________
Answer
-
3 wire system
-
1 wire system
-
2 wire system
-
4 wire system
Question 57
Question
3-phase systems are known as __________
Answer
-
3 wire system
-
1 wire system
-
2 wire system
-
4 wire system
Question 58
Question
which is true about a single phase?
Question 59
Question
which is true about a three phase high?
Question 60
Question
which is true about a three phase low?
Question 61
Question
how can you tell the difference between a three-phase low and a single-phase circuit panel?
Answer
-
three-phase circuit panel has a black, red, and blue hot, white neutral, and green ground.
-
single-phase circuit panel has a black, red, and blue hot, white neutral, and green ground.
-
single-phase circuit panel has a black, and red hot, white neutral, and green ground.
-
three-phase circuit panel has a black, and red hot, white neutral, and green ground.
Question 62
Question
three-phase high has brown, orange/purple, and yellow hot wires.
Question 63
Question
Romex is used primarily in commercial construction
Question 64
Question
The 6'7" rule is for what?
Answer
-
The maximum height of a breaker switch is 6'7"
-
The maximum distance any equipment near the breaker panel is 6'7"
-
The minimum height of a breaker switch is 6'7"
-
The minimum distance any equipment near the breaker panel is 6'7"
Question 65
Question
the National Electric Code has a 6 handle rule. Meaning, that if a building has less than 6 disconnect, it does not need a main disconnect.
Question 66
Question
__________ is the least efficient lighting.
Answer
-
Incandescent
-
LED
-
Fluorescent
Question 67
Question
__________ lighting is hazardous for disposal.
Answer
-
Incandescent
-
LED
-
Fluorescent
Question 68
Question
__________ lighting is the most efficient.
Answer
-
Incandescent
-
LED
-
Fluorescent
Question 69
Question
blue light is 10,000K
Question 70
Question
yellow light is 3000K
Question 71
Question
Warm Light ------------------------------------------------Cool Light
10,000K----------------------------------------------------------1,000K
Question 72
Question
This is an example of a lay-in fixture, troffer, or a grid mounted lighting fixture.
Question 73
Question
Pendant fixtures have one cable/support suspending from a surface.
Question 74
Question
High bay/suspended lighting fixtures are at least 15' from the FFE
Question 75
Question
Recessed fixtures are flush mounted
Question 76
Question
surface lighting fixtures are stuck to the surface of a ceiling.
Question 77
Question
track mounted lighting are adjustable in direction and can be removed from the track.
Question 78
Question
an inverter is only for emergency lighting.
Question 79
Question
__________ is a popular option for emergency lighting.
Answer
-
bug eye
-
frog eye
-
track mounted
-
surface mounted
-
structure mounted
-
sconce
Question 80
Question
the [blank_start]chevron(s)[blank_end] on the EXIT signs indicate direction [blank_start]out[blank_end] of the building
Answer
-
chevron(s)
-
arrows
-
frog eye
-
bug eye
-
out
-
in
Question 81
Question
two options for controlling exterior lighting at night time.
Answer
-
photo cell
-
timer
-
light cell
-
wall packs
Question 82
Question
flag lights are usually placed at the top of a light pole
Question 83
Question
how can someone be electrocuted from a power line?
Question 84
Question
grounding is NOT needed on a building in order to function
Question 85
Question
grounding is simply a safety feature.
Question 86
Question
electrons travel underground when grounded
Question 87
Question
you can have a ground on a conduit inside of the building.
Question 88
Question
grounding moves the electrons from the load back to the __________ (final destination)
Answer
-
power source
-
ground
-
main distribution panel
-
electrical meter
Question 89
Question
answer based on if the information in the image is correct
Question 90
Question
answer based on if the information in the image is correct
Question 91
Question
leaders are put on top of buildings for __________________
Answer
-
lightning protection - path for lightning to go around the building rather than through the building
-
lightning protection - path for lightning to go in the building rather than around the building
-
electrocution protection - path for lightning to go around the building rather than through the building
-
electrocution protection - path for lightning to go in the building rather than around the building
Question 92
Question
3-pole breakers ONLY use 3 phase
Question 93
Question
only 1-pole and 2-pole breakers use a single phase.