Question 1
Question
What is the recommended power range for microscopes to view the end face of an optical fiber connector
Answer
-
100x-200x
-
100x-800x
-
200x-400x
Question 2
Question
_____ cabling provides interconnection between TRs, ERs, main terminal space & EF (entrance facilities)
Answer
-
backbone
-
horizontal
-
riser
Question 3
Question
To confine the light within the core by creating a reflective boundary is the purpose of the _______
Question 4
Question
This space is a special purpose room that provides and maintains a suitable operating environment for large telecommunications equipment
Question 5
Question
During a retrofit, it is not required to remove all abandoned cable
Question 6
Question
This space should not serve more than 3,600 sq/ft
Question 7
Question
What is the most common specialty fastener used in ITS cabling
Answer
-
j-hook
-
toggle bolt
-
drive ring
-
bridal ring
Question 8
Question
Interbuilding circuits are considered to have lightning exposure unless 1 or more conditions exist (select all correct)
Answer
-
Buildings close together and sufficiently high
-
Cable run is 140ft or less (underground or in conduit)
-
Area having an avg. of 5 or fewer t-storms per year and earth resistivity less than 100 ohms
Question 9
Question
This tester uses Rayleigh scattering & Fresnal reflection to measure the characteristics of an optical fiber
Question 10
Question
The ITS installer is allowed to add more firestopping product to get a higher rating
Question 11
Question
Cross-Connect Field Colors: Future (Key Telephone Systems)
Question 12
Question
What is used to flush electrolyte burns to the skin
Answer
-
water
-
milk
-
sodium bicarbonate
Question 13
Question
Shorter wavelengths of light exhibit greater amounts of attenuation because of Rayleigh scattering
Question 14
Question
Longer wavelengths are more sensitive to bending loss and will allow light to exit out of the fiber core more than shorter wavelengths
Question 15
Question
What is the minimum separation of telecommunications cabling and electric motors & transformers
Answer
-
12 inches
-
36 inches
-
48 inches
-
60 inches
Question 16
Question
This firestop material has the ability to absorb heat to prevent the temperature from rising on the other side of the fire barrier
Answer
-
endothermic
-
ablative
-
intumescent
Question 17
Question
Where does the SCS begin
Answer
-
where the SP terminates
-
ER
-
TR
Question 18
Question
What is the signal range for POTS
Answer
-
300Hz-3400Hz
-
300MHz-3400MHz
-
20Hz-20,000Hz
Question 19
Question
This type of protector has a reaction time of 1-2 ns
Answer
-
fire & data
-
carbon
-
gas
-
solid state
Question 20
Question
Cross-Connect Field Colors: Interbuilding Backbone
Question 21
Question
The frequency of CAT5e is
Answer
-
100MHz
-
250MHz
-
500MHz
-
150MHz
Question 22
Question
The frequency of CAT3 is
Question 23
Question
The frequency of CAT6a is
Answer
-
100MHz
-
250MHz
-
350MHz
-
500MHz
Question 24
Question
The frequency of CAT6 is
Answer
-
100MHz
-
250MHz
-
350MHz
-
500MHz
Question 25
Question
How many pairs are in a super group
Question 26
Question
How many binder groups are in each super group
Question 27
Question
What are the 2 common methods of terminating balanced twisted pair cable (select all correct)
Question 28
Question
Which of the following cables meet the minimum requirements for cabling to a work area (select all correct)
Answer
-
4 pair, 100 Ohm CAT5e cable
-
4 pair, 100 Ohm CAT6 cable
-
2 or more strands of 62.5 or 50 (OM1 or OM2)
-
2 or more strands of singlemode
Question 29
Question
Why is undercarpet cable not recommended (select all correct)
Question 30
Question
The interconnection between undercarpet cable and horizontal cable is called what
Answer
-
TP (transition point)
-
CP (consolidation point)
-
MUTOA
Question 31
Question
If using undercarpet cable, what is recommended maximum length of the cable
Question 32
Question
What are the most common connectors for multimode fiber (select all correct)
Question 33
Question
What are the common modular connectors used in ITS (select all correct)
Question 34
Question
What are the most predominant coaxial cables (select all correct)
Answer
-
Series 6
-
Series 59
-
Series 11
-
RG6
-
RG58
-
RG59
Question 35
Question
The F connector is the most commonly used connector for residential cable service
Question 36
Question
What are the common BNC connector types (select all correct)
Answer
-
3 piece crimp
-
1 piece compression
-
screw-on
Question 37
Question
What is the maximum pulling tension of 4-pair, balanced twisted pair cabling
Answer
-
25 pounds-force (lbf)
-
20 pounds-force (lbf)
-
30 pounds-force (lbf)
Question 38
Question
What is the minimum bend radius of 4 pair cable
Answer
-
4 times cable diameter
-
5 times cable diameter
-
4 inches
-
5 inches
Question 39
Question
What is the recommended service slack for 4-pair cables at the work area
Answer
-
12 inches
-
24 inches
-
36 inches
Question 40
Question
What is the recommended service slack for a 4 pair cable in the TR/ER
Question 41
Question
What is the recommended service slack for multipair cable in a TR/ER
Question 42
Question
What is the recommended service slack for 4 pair & multipair cable at a TE
Question 43
Question
The tensile strength of pull string is typically
Answer
-
75-200 lbf
-
100-200 lbf
-
50-100 lbf
-
75-150 lbf
Question 44
Question
A pull string should be attached to cable with what type of knot and how many knots
Answer
-
3 half hitches
-
2 half hitches
-
3 square knots
-
2 square knots
Question 45
Question
Structural steel members (red iron) can be used to support cables if they are spaced 4-5ft
Question 46
Question
What are the common splice connectors for copper (select all correct)
Answer
-
straight through
-
butt splice
-
half tap
Question 47
Question
What are the common splice enclosures (select all correct)
Question 48
Question
Which copper splicing method allows the conductors to be folded into the splice and allows for maintenance, rearrangement and transfer of the conductors
Answer
-
Inline
-
Foldback
-
Butt
-
Branch
Question 49
Question
What is the minimum bend radius of a 4 pair balanced twisted pair cord
Answer
-
1x patch cord diameter
-
4x patch cord diameter
-
4 inches
-
2 inches
Question 50
Question
What is the minimum bend radius of a multipair cable
Question 51
Question
Cable pair twists for CAT3 must be maintained to within ____________ of termination
Answer
-
3 inches
-
2 inches
-
1 inch
-
.5 inches
Question 52
Question
Cable pair twists for CAT5e or higher must be maintained to within ____________ of termination
Answer
-
.5 inches
-
.25 inches
-
.75 inches
-
1 inch
Question 53
Question
110 blocks come in increments of ________ pairs (select all correct)
Question 54
Question
BIX blocks come in increments of ________ pairs (select all correct)
Question 55
Question
Field terminated patch cables are not recommended for CAT5e
Question 56
Question
What is the most common video connector in the industry
Question 57
Question
Specification and visual inspection is what phase of testing
Question 58
Question
Testing with various test equipment is what phase of testing
Question 59
Question
Documentation is what phase of testing
Question 60
Question
Except in particular cases, what is the maximum length of equipment cords
Question 61
Question
A consolidation point will extend the horizontal cabling length
Question 62
Question
What is the maximum amount of work areas that a MUTOA should serve
Question 63
Question
A minimum of 1 dedicated, non-switched duplex receptacle should be available for equipment in each _________
Question 64
Question
What is the maximum square footage a TE should serve
Question 65
Question
What is minimum recommended cable tray width for an ER, TR or EF
Answer
-
12 inches
-
18 inches
-
6 inches
-
24 inches
Question 66
Question
Which grade of plywood has knotholes without any repair
Answer
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Question 67
Question
Which grade of plywood contains some blemishes and the occasional knothole
Answer
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Question 68
Question
Which grade of plywood has the knotholes cut out and replaced with a patch of clean wood
Answer
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Question 69
Question
Which grade of plywood is the highest grade and is without any surface blemishes
Answer
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Question 70
Question
Which grade of plywood should be used for ER, TR & EFs
Question 71
Question
How many walls should have plywood installed
Question 72
Question
Select all that apply to backboards in ERs, TRs & EFs
Answer
-
3/4" thick plywood
-
at least 2 coats of fire retardant paint
-
minimum 1/4" toggle bolts
-
toggle bolts should be spaced 24 inches
-
toggle bolts should be 2 inches from the edge of the plywood
-
plywood should be mounted 6 inches AFF
Question 73
Question
Most ITS installations will require a 19 inch by 7 ft rack
Question 74
Question
What are the common depths of racks (select all correct)
Question 75
Question
What are the popular thread sizes for racks/cabinets (select all correct)
Question 76
Question
What is the preferred size of patch panels
Question 77
Question
What are the reasons that FMT is not recommended (select all correct)
Answer
-
creep
-
shift
-
damage cable sheath
Question 78
Question
If using FMT, what rules must be followed (select all correct)
Question 79
Question
How many 90 degree bends are allowed in conduit segment
Question 80
Question
If more than two 90 degree bends are needed, what must be done (select all correct)
Answer
-
run is not longer than 33ft
-
increase conduit 1 trade size
-
install one 90 degree bend within 12 inches of feed end
Question 81
Question
When conduits enter a TR through the floor, how far should they protrude
Answer
-
6 inches
-
2-4 inches
-
1-3 inches
Question 82
Question
What are the 3 common depths of basket tray (rod stock tray) (select all correct)
Question 83
Question
This is the portion of the data center that actually houses the IT equipment
Answer
-
Computer Room
-
Equipment Room
-
Entrance Room
Question 84
Question
Which types of cables are recognized in data center telecommunications (select all correct)
Question 85
Question
Which two types of coaxial cable does ANSI/TIA 942 recognize for E1, E3 & T3 circuits (select all correct)
Answer
-
734-type
-
735-type
-
Series 6
-
Series 11
Question 86
Question
Which type of connectors are installed on 734-type and 735-type coaxial cable for E1, E3 & T3 circuits (select all correct)
Question 87
Question
Cable trays in data centers should be planned for initial maximum calculated fill ratio of ________%
Question 88
Question
How much clearance should be provided above the of cable trays when they are installed above cabinets
Answer
-
12 inches
-
10 inches
-
6 inches
-
18 inches
Question 89
Question
How much clearance should be above a cable tray that is installed below a raised floor
Answer
-
2 inches
-
3 inches
-
6 inches
-
12 inches
Question 90
Question
Cable trays installed under raised floors in data centers should be installed in the cold aisle
Question 91
Question
In a data center, how much horizontal cable management should be provided for each 1u of patch panel
Question 92
Question
Power strips supporting only single-corded equipment should be loaded no more than _______% of circuit capacity
Question 93
Question
Power strips supporting only dual-corded equipment should be loaded no more than _______% of circuit capacity
Question 94
Question
Some unique aspects of health care regarding access control are (select all correct)
Answer
-
elevator controls (cab calls and override)
-
integration will infant protection, wandering patient and elopement systems
-
card readers not always being located at the door
-
multiple levels of access control for care providers, visitors and security
Question 95
Question
In a health care facility, PT (pneumatic tube) system is typically what size tubing
Question 96
Question
Central equipment cabinets are the heart of the system and likely will occupy 4ft x 8ft of wall space in the TR
Question 97
Question
HEPA/ultra-low penetration air (ULPA) vacuum cleaners shall trap _________% of particles 0.12 micrometers and larger
Question 98
Question
In health care facility projects, the safety officer or facilities director shall make at least _________ documented visit(s) per week to each construction work zone
Question 99
Question
This document is the understanding between the customer and the contractor
Answer
-
project contract
-
scope of work
-
specifications
Question 100
Question
CLA Series System Drawings: Campus or Site Plans
Question 101
Question
CLA Series System Drawings: Layout of complete building per floor
Question 102
Question
CLA Series System Drawings: Serving Zones: drop locations and cable IDs
Question 103
Question
CLA Series System Drawings: Communication equipment rooms
Question 104
Question
CLA Series System Drawings: Typical detail drawings: face-plate labeling, firestopping
Question 105
Question
CLA Series System Drawings: Schedules
Question 106
Question
What are the 3 major areas in security that may be part of an ITS installer's work (select 3)
Question 107
Question
A fire alarm system should be designed by a licensed fire protection engineer to ensure proper coverage and code compliance
Question 108
Question
DAS consists of an infrastructure of electronic devices including (select all correct)
Answer
-
amplifiers
-
cabling
-
connectors
-
antennas
-
hardware
Question 109
Question
This is a device that transmits and receives electromagnetic waves
Answer
-
antenna
-
transmitter
-
transceiver
Question 110
Question
Each 6dB increase in an antenna equals the ___________ of the possible range
Question 111
Question
Each 6dB decrease in an antenna equals the ___________ of the possible antenna range
Question 112
Question
The standoffs for a radiating cable need to be _______ inches below the cable tray
Answer
-
2 inches
-
3 inches
-
4 inches
-
6 inches
Question 113
Question
Wireless access points should be mounted at least ________ meter(s) from any metal obstructions
Question 114
Question
Most antennas used with APs indoors come with a ______ cable, commonly known as a pigtail
Question 115
Question
What are the 3 common voltages used in centrally amplified systems (select 3)
Question 116
Question
Which paging system operates at 24vdc
Question 117
Question
Which paging system will typically have 2 conductor cable installed
Answer
-
centrally amplified
-
distributed amplified
Question 118
Question
What are the 2 common types of sound masking systems (select 2)
Answer
-
in-plenum
-
direct-field
-
above ceiling
Question 119
Question
What time each day does the master clock send a longer pulse that corrects all of the secondary clocks to the correct hour
Question 120
Question
D-loading coils are commonly placed by telephone companies at which distance
Question 121
Question
H-loading coils are most commonly placed by the telephone company at which distance
Question 122
Question
Loss for premise cabling, including taps, should not exceed _____ dB of loss