Munition Handling and Loading Equipment: Quiz 2

Description

Quiz 2
Joseph Whilden J
Quiz by Joseph Whilden J, updated more than 1 year ago
Joseph Whilden J
Created by Joseph Whilden J over 8 years ago
21
1

Resource summary

Question 1

Question
How many different outputs can an A/M 32A-60 provide?
Answer
  • 2
  • 3
  • 4
  • 5

Question 2

Question
Which item is the only auxiliary power unit (APU) to provide both electrical and pneumatic power?
Answer
  • A/M 32A-60
  • A/M 32A-86
  • A/M 32A-95
  • MC-2A

Question 3

Question
Where is the A/M 32A-60 pneumatic duct hose stored?
Answer
  • On the unit's roof housing
  • In the rear storage compartment
  • In the front storage compartment
  • In the chassis storage compartment

Question 4

Question
Identify the output of the A/M 32A-95
Answer
  • 28 VDC
  • Bleed air
  • 120 VAC, single-phase, 400 Hz
  • 120/208 VAC, three-phase, 400 hz

Question 5

Question
Due to the expansion properties of fuel, an unmodified A/M 32A-95 fuel tank should not be filled more than approximately how full?
Answer
  • 1/3
  • 1/2
  • 5/8
  • 3/4

Question 6

Question
Which electrical output is supplied by the A/M 32A-86 generator set?
Answer
  • 110/120 VAC or 208/230 VAC
  • 115/200 VAC or 230/400 VAC
  • 120/208 VAC
  • 28 VDC

Question 7

Question
How many instruments/control panels must the operator make use of during operation of the A/M 32A-86 generator set?
Answer
  • 1
  • 2
  • 3
  • 4

Question 8

Question
Which panel of the A/M 32A-86 generator set has the circuit breaker to shut off current flow in case of an overload?
Answer
  • Generator control
  • Engine control
  • External AC
  • External DC

Question 9

Question
Which auxiliary power unit serves as an external power source for the MQ-1 and MQ-9 aircraft?
Answer
  • A/M 32A-60
  • A/M 32A-86
  • A/M 32A-95
  • Starter cart assembly (SCA)

Question 10

Question
Where is the control panel of the starter cart assembly (SCA) located?
Answer
  • Underneath a cover located at the top of the unit
  • On the engine monitoring panel
  • On the power outlet located on the right side of the generator set
  • On the starter cart assembly electronics tray

Question 11

Question
An operator is not required at or in the immediate vicinity of an in-use auxiliary power unit (APU) when they are practicing loading
Answer
  • High explosive munitions
  • Live nuclear weapons
  • Live chemical weapons
  • Inert training munitions

Question 12

Question
Fighter aircraft may be exempted from the 50 foot distance placement requirements of an auxiliary power unit (APU) during
Answer
  • Combat operations only
  • Simulated combat operations only
  • Combat or simulated combat operations
  • Combat, simulated combat, or adverse weather conditions

Question 13

Question
Which area must you void when operating units powered by turbine engines?
Answer
  • Engine air intake
  • Engine air exhaust
  • Engine plane of rotation
  • Power unit bleed air service hose

Question 14

Question
Which air compressor may be used to per ate small pneumatic tools?
Answer
  • MC-1A
  • MC-2A
  • MD-3
  • A/M 32A-60

Question 15

Question
How much air pressure is produced by the MC-2A air compressor?
Answer
  • 5 cfm at 200 psi
  • 15 cfm at 200 psi
  • 5 cfm at 3200 psi
  • 15 cfm at 3200 psi

Question 16

Question
Before you connect or disconnect a high-pressure service hose, you must make sure the system is not
Answer
  • Pressurized with more than 100 psi
  • Pressurized with more than 15 psi
  • Pressurized fully
  • Pressurized

Question 17

Question
Which power output of a portable floodlight set is used for powering common electrically powered hand tools?
Answer
  • 28 VDC
  • 115-120 VAC
  • 220-240 VAC
  • 225-300 VAC

Question 18

Question
The FL-1D can serve as a ground power source for MQ-1 and MQ-9 aircraft when used in conjunction with a/an
Answer
  • MC-2A air compressor
  • A/M 32A-60 generator set
  • A/M 32C-10A air conditioner
  • DCs40-75 "Sorensen" power supply unit

Question 19

Question
When can you use the floodlight receptacles for external power to operate accessories
Answer
  • When 115-120 VAC is required
  • When 110-115 VAC is required
  • When 235-300 VAC is required
  • Never, these receptacles cannot be used to operate accessories

Question 20

Question
How are flood lights positioned when working around aircraft?
Answer
  • Downwind from the A/C
  • At the end of their power cord
  • 50 feet away from the A/C nearest point
  • As far away as possible from the A/C, while still providing adequate lighting

Question 21

Question
In which position must the FL-1D's floodlight platform be placed during towing?
Answer
  • Any position
  • Lowered halfway
  • Lowered completely
  • Lowered just enough to clear overhead obstacles

Question 22

Question
Which storage compartment is the A/M 32C-10 duct hoses stored?
Answer
  • Unit's roof housing
  • Rear
  • Front
  • Chassis

Question 23

Question
Which A/M 32C-10 control panel will you use when operating the system?
Answer
  • High pressure air controls
  • Conditioned air controls
  • Generator control panel
  • Direct current (DC) power panel

Question 24

Question
How far from the supported aircraft should the A/M 32C-10 air conditioner be positioned for optimum unit operating efficiency and safety?
Answer
  • 8 to 10 feet
  • 10 to 12 feet
  • 15 to 30 feet
  • 50 feet minimum

Question 25

Question
Which per pound per square inch (psi) is the maximum amount of bleed-air pressure that may be applied to the -10 air conditioner?
Answer
  • 15 psi
  • 25 psi
  • 35 psi
  • 45 psi

Question 26

Question
How many operators are required to be present during the operation of the -10 air conditioner?
Answer
  • 1
  • 2
  • 3
  • 4

Question 27

Question
Which additional piece of aerospace ground equipment (AGE) is required during the operation of the polyalphaolefin (PAO)/air cooling cart?
Answer
  • A/M 32A-60 generator set
  • A/M 32A-86 generator set
  • A/M 32A-95 generator set
  • None, it is a self-contained system

Question 28

Question
How many fluid temperature modes are available on the polyalphaolefin (PAO)/air cooling cart?
Answer
  • 1
  • 2
  • 3
  • 4

Question 29

Question
How does the operator initiate the delivery of polyalphaolefin fluid once it has reached proper operating temperature?
Answer
  • By closing the aft restrictor valve
  • By opening the aft restrictor valve
  • By opening the aft restrictor manifold
  • The operator takes no action, the polyalphaolefin (PAO)/air cooling cart begins fluid delivery automatically

Question 30

Question
Which action must be ensured before making or breaking a connection between the polyalphaolefin (PAO)/air cooling cart and the aircraft?
Answer
  • Cart power is off
  • System is depressurized
  • Servicing lines are bled
  • Servicing lines are free of kinks

Question 31

Question
The cool-air hatch on the MJ-2A hydraulic test stand is located on the unit, by which location on the unit?
Answer
  • Rear
  • Front
  • Side
  • Top

Question 32

Question
Which personnel protective equipment (PPE) must be worn when you operate the MJ-2A?
Answer
  • Goggles
  • Ear protectors
  • Gloves
  • Coveralls

Question 33

Question
Identify the primary reason for making sure aircraft fittings are clean before attaching hydraulic servicing hoses?
Answer
  • Dirty fittings will cause damage to the threads of the connectors on the test stand
  • Dirty fittings can cause an incomplete seal with the hoses resulting in leaks at the attach points
  • Dirty fittings can introduce contaminants to the hydraulic system causing damage to valves and lines
  • Dirt can scour protective coatings off of the fittings that will allow then to corrode when bare metal is subjected to the environment

Question 34

Question
Which aircraft(s) require aircraft armament system personnel to use the self-generating nitrogen servicing cart (SGNSC)?
Answer
  • F-15, F-16, and F-22
  • B-1, B-2, and B-52
  • F-15 and F-15E
  • F-22 only

Question 35

Question
When using the self-generating nitrogen servicing cart (SGNSC) why is it important that waste gasses are not allowed to accumulate in an enclosed space?
Answer
  • Dangerous levels of carbon monoxide can build up displacing space
  • Dangerous levels of carbon dioxide can build up displacing oxygen
  • Excess nitrogen can pose a fire or explosion hazard
  • Excess oxygen can pose a fire or explosion hazard

Question 36

Question
Why is it important to prevent venting the self-generating nitrogen servicing cart (SGNSC) storage tanks in an enclosed space without sufficient ventilation?
Answer
  • Excess nitrogen can pose a fire/explosion hazard
  • Venting of high pressure gas is extremely loud and could damage hearing
  • A dangerous overpressure situation could occur causing harm to personnel and damage to structures
  • Large volumes of nitrogen can displace the oxygen in the air, making it possible for a person to suffocate without warning

Question 37

Question
Which precaution must be taken prior to attempting to loosen fittings, or removing tubes or hoses when using the self-generating nitrogen servicing cart (SGNSC)?
Answer
  • Ensure cart power is off
  • Ensure the entire system is depressurized
  • You must vent the pressure from that part of the system through the appropriate valve
  • Ensure the carts high pressure storage tanks main shutoff valves are in the "NO-FLOW" position

Question 38

Question
the maximum static load the B-1maintenance stand can sustain is
Answer
  • 300 pounds
  • 400 pounds
  • 500 pounds
  • 600 pounds

Question 39

Question
Identify the platform height range of the B-4 maintenance stand?
Answer
  • 3 to 7 feet
  • 4 to 8 feet
  • 3 to 10 feet
  • 4 to 12 feet

Question 40

Question
The hand pump for raising the B-4 maintenance stand is located on the
Answer
  • Platform near the ladder
  • Remote control unit (RCU)
  • Base of the stand near the aft castors
  • Base of the stand near the forward castors

Question 41

Question
Which maintenance stand is described as a scissors-type, with a variable height platform, and mounted on a long-legged caster-equipment base?
Answer
  • B-1
  • B-4
  • B-5
  • C-1

Question 42

Question
Identify the platform height range of the B-5 maintenance stand
Answer
  • 1 to 7 feet
  • 1 to 10 feet
  • 7 to 12 feet
  • 7 to 15 feet

Question 43

Question
Which stand can be used independently, or can be installed as an extension on the B-1maintenance stand?
Answer
  • B-2
  • B-4
  • B-5
  • C-1

Question 44

Question
The lifting capacity of the davit on the split deck is
Answer
  • 200 - 500 pounds
  • 250 - 500 pounds
  • 300 - 500 pounds
  • 350 - 500 pounds

Question 45

Question
If the split-deck maintenance platform's tape switches detect an obstruction during an operation, what will the switches stop on the unit?
Answer
  • Forward drive capacity only
  • Platform extension capability
  • Platform extension and lowering capabilities only
  • Forward drive, platform extension and lowering capabilities

Question 46

Question
During an operator's pre-use inspection of aerospace ground equipment (AGE), what is required by the operator to ensure proper unit operation?
Answer
  • Check the AFTO 781K
  • Check the AGE personnel as the status of the unit
  • Cycle the unit through the capabilities that you will use
  • Cycle the unit completely through its range of capabilities

Question 47

Question
Which AFTO form is used to annotate any defects you may find on your aerospace ground equipment (AGE)?
Answer
  • AFTO Forms 244 and 245
  • AFTO Form 349
  • AFTO Form 350
  • AFTO Form 781A
Show full summary Hide full summary

Similar

Hort100 Final Quiz 2
Madalyn Geuke
Introduction: What is Civilization?
Anita Thomer
2W151 Volume 1: Administration, Management, and Publications - Quiz 2
Joseph Whilden J
LAWS, REGULATIONS AND CONTROLLED SUBSTANCES
Rebecca West
Ionic Bondic Flashcards.
anjumn10
LOGARITHMS
pelumi opabisi
A-level Maths: Key Differention Formulae
Andrea Leyden
Life in Germany
Ben C
GCSE REVISION TIMETABLE
gracemiddleton
C1 Quiz
Leah Firmstone
New English Literature GCSE
Sarah Egan