Basic Shoulder Training Assessment

Description

Assessment post basic shoulder training.
Andrew Costello
Quiz by Andrew Costello, updated more than 1 year ago
Andrew Costello
Created by Andrew Costello about 7 years ago
13
0

Resource summary

Question 1

Question
Who is credited with designing the reverse shoulder arthroplasty?
Answer
  • Charles Neer
  • Enrico Gervasi
  • Paul Grammont
  • Mario Randelli

Question 2

Question
What degree of retroversion is needed for an SMR anatomical shoulder?
Answer
  • 10 Degrees
  • 20 Degrees
  • 30 Degrees
  • None of the above

Question 3

Question
What two ways below does the SMR system help to reduce the risk of scapula notching?
Answer
  • Using a metal back glenoid
  • Reversing the materials between the glenosphere and the liner
  • Distal fixation of the stem
  • Placing a chamfered edge on the liner

Question 4

Question
Why was there a need to invent the reverse shoulder?
Answer
  • Patients who had avascular neucrosis
  • Young patients who suffered trauma
  • Patients with Cuff tear arthropathy
  • To help prevent overstuffing of the joint

Question 5

Question
The 36mm Glenosphere is available in Polyethylene?
Answer
  • True
  • False

Question 6

Question
How many sizes of SMR Glenoid metal-back are available?
Answer
  • 1
  • 2
  • 3
  • 4

Question 7

Question
What makes the SMR metal back glenoid different to earlier designs of metal back components? (2 correct answers)
Answer
  • Trabecular Titanium Material
  • Multiple screw hole options
  • Concave shape
  • Large central peg

Question 8

Question
What Muscle is needed for a reverse shoulder replacement to work?
Answer
  • Deltoid
  • Biceps
  • Rotator Cuff
  • Triceps

Question 9

Question
What muscle group needs to be functioning for an anatomic shoulder replacement to work?
Answer
  • Deltoid
  • Biceps
  • Rotator Cuff
  • Triceps

Question 10

Question
The SMR system offers cemented and cementless glenoid components?
Answer
  • True
  • False

Question 11

Question
When you have a deficient rotator cuff, what commonly happens to the humeral head when the deltoid is engaged?
Answer
  • Lateralises
  • Moves inferiorly
  • Moves superiorly
  • Nothing

Question 12

Question
What is Scapula Notching?
Answer
  • Metal ions released causing scapula to resorb
  • Poly debris caused by the poly liner articulating with the scapula and causing bone resorption
  • A naturally occurring phenomenon
  • Hyper extension of the shoulder

Question 13

Question
Which of the following trays are needed for an anatomic hemi shoulder replacement? (choose all correct answers
Answer
  • Common instrument Set
  • Endoprosthesis Instrument Set
  • Glenoid Instrument Set
  • Reverse instrument Set
  • SMR Reverse HP

Question 14

Question
Which of the following trays are needed for a reverse shoulder replacement using a 40mm Poly gleonsphere? (choose all correct answers)
Answer
  • Common instrument Set
  • Endoprosthesis Instrument Set
  • Glenoid Instrument Set
  • Reverse instrument Set
  • SMR Reverse HP

Question 15

Question
When using the conical reamer to prepare for a reverse body, what tip can be used to ensure the reamer has been sunk deep enough?
Answer
  • Reading the gauge on the reamer shaft
  • Using a version rod
  • Inserting a 2.0mm k-wire in hole in the reamer near the cutting teeth
  • Eyesight

Question 16

Question
What sizes of peg are available for the cementless metal back?
Answer
  • Small-R
  • Small - Standard
  • Medium
  • Long

Question 17

Question
What is the advantage of an inlay platform system?
Answer
  • Easier surgical approach
  • Greater range of stem options
  • Reduces likelihood of overstuffing the joint
  • Reduces the likelihood of scapula notching

Question 18

Question
How old was the SMR system in 2017?
Answer
  • 5 years
  • 10 Years
  • 15 Years
  • 20 Years

Question 19

Question
True or false a Small- R poly liner can be used with a small metal-back glenoid component?
Answer
  • True
  • False

Question 20

Question
What additional step is needed after coupling (using the taper) an anatomic or reverse body to a stem?
Answer
  • Safety screw needs engaging
  • Safety screw needs removing
  • A second taper needs to be coupled
  • No further steps needed
Show full summary Hide full summary

Similar

Mocktical #2
Neel Vahil
To Kill A Mockingbird
tommarlin15
Spanish Vocabulary- Beginner
ThomasK
The Rise of the Nazis
absterps18
Respiratory System
Addeana
The Brain and the Nervous System
feelingthepayne
Spanish Subjunctive
MrAbels
Biology (B2)
Sian Griffiths
Conferences of the Cold War
Alina A
Organic Nomenclature
mahnoor.gohar
What are assessments and what do they measure?
mtyler12008