Class D Wastewater Sample Questions

Descripción

Wastewater Wastewater Treatment Study Material Test sobre Class D Wastewater Sample Questions, creado por Dean Lampman el 16/12/2017.
Dean Lampman
Test por Dean Lampman, actualizado hace más de 1 año
Dean Lampman
Creado por Dean Lampman hace más de 6 años
58
1

Resumen del Recurso

Pregunta 1

Pregunta
What Is not run on raw influent wastewater?
Respuesta
  • CBOD
  • FECAL Coliform
  • Suspended Solids
  • pH

Pregunta 2

Pregunta
What disease is not considered to be conveyed or transmitted by untreated wastewater?
Respuesta
  • Amoebic Dysentery
  • Hepatitis
  • Malaria
  • Cholera

Pregunta 3

Pregunta
What effect will the addition of chlorine, acid, alum. carbon dioxide, or sulfuric acid have on the pH of wastewater?
Respuesta
  • Neutralize
  • Lower
  • Increase
  • Have no effect

Pregunta 4

Pregunta
Coliform bacteria are
Respuesta
  • Algae
  • Coagulant aids
  • Indicators
  • Sequestering agents

Pregunta 5

Pregunta
Which of these pH readings indicates an acidic wastewater?
Respuesta
  • 3
  • 7
  • 9
  • 12

Pregunta 6

Pregunta
Three waterborne diseases are
Respuesta
  • Mumps, measles, colds
  • Scarlet fever, pneumonia, hay fever
  • Typhoid fever, dysentery, cholera
  • TB, diptheria, chickenpox

Pregunta 7

Pregunta
Which one of the following conditions increase chlorine demand?
Respuesta
  • Alkalinity
  • Increase in organic matter
  • Increase in phosphate
  • pH increase

Pregunta 8

Pregunta
A chlorine leak can be detected by
Respuesta
  • An explosimeter
  • Checking the leak guage
  • Spraying water on suspected leaks
  • A white cloud in presence of ammonia fumes

Pregunta 9

Pregunta
Turbidity in wastewater is caused by
Respuesta
  • Finely divided suspended material
  • Dissolved calcium
  • Hardness
  • Color

Pregunta 10

Pregunta
Dark tan and shiny foam is produced when
Respuesta
  • F/M ratio is too low
  • Insufficient aeration tank capacity
  • Young Sludge
  • RAS rate inappropriate

Pregunta 11

Pregunta
The pH of wastewater
Respuesta
  • Always increases as acid concentrations increase
  • Always increases when wastewater becomes septic
  • is measured on a scale of 0 to 14
  • is measured on a scale of 0 to 100 mg/L

Pregunta 12

Pregunta
Which of the following conditions are likely to have been caused by biological activity that is prompted by long, sluggish flow in a flat grade sewer line?
Respuesta
  • Concrete and metal corrosion
  • Oxygen deficiency in manholes, sewers, and wet-wells
  • Toxic gas production
  • All of the answers

Pregunta 13

Pregunta
Sand, silt, and grit are composed of what kind of matter?
Respuesta
  • Colloidal
  • Inorganic
  • Organic
  • Volatile

Pregunta 14

Pregunta
Which of the following statements is NOT indicative of fresh wastewater?
Respuesta
  • Contains some dissolved oxygen from the water supply
  • is being decomposed by facultative bacteria
  • is blackish in color, with rotten egg odor
  • is turbid with solids in suspension

Pregunta 15

Pregunta
How much does a gallon of water weigh?
Respuesta
  • 9.34 lbs
  • 8.34 oz
  • 7.5 lbs
  • 8.34 lbs

Pregunta 16

Pregunta
Organic solids in wastewater are
Respuesta
  • Generally of vegetable and animal origin
  • Inert and not subject to decay
  • Mostly floatable solids
  • Always settleable solids

Pregunta 17

Pregunta
The purpose of primary sedimentation is to remove
Respuesta
  • Pathogenic bacteria
  • Roots, rags, cans, and large debris
  • Sand and gravel
  • Settable and floatable material

Pregunta 18

Pregunta
One cubic foot of water contains how many gallons?
Respuesta
  • 2.31 gallons
  • 7.48 gallons
  • 8.34 gallons
  • 10 gallons

Pregunta 19

Pregunta
The seepage of groundwater into sewer lines through cracks and open joints is called
Respuesta
  • Inflow
  • Infiltration
  • A blessing in disguise
  • Sanitary sewage

Pregunta 20

Pregunta
The direct flow of rainwater into a sewer line through ground level openings and breaks is
Respuesta
  • Inflow
  • Infiltration
  • Industrial sewage
  • Sanitary sewage

Pregunta 21

Pregunta
_______________ is the most common and prevalent odorous gas associated with domestic wastewater collection systems.
Respuesta
  • Chlorine
  • Hydrogen sulfide
  • Carbon dioxide
  • Methane

Pregunta 22

Pregunta
Which of the following factors could cause a demand for more DO (Increase in aeration rate) in an aeration tank?
Respuesta
  • Increase in food (BOD) in the aeration tank influent
  • Decrease in organic wastewater
  • Increase in influent DO
  • Increase in toxic substances

Pregunta 23

Pregunta
Chlorine is _____ times heavier than air
Respuesta
  • 1.5
  • 2.0
  • 2.5
  • 3.0

Pregunta 24

Pregunta
The liquid to gas expansion ration of chlorine is
Respuesta
  • 25 to 1
  • 250 to 1
  • 460 to 1
  • 500 to 1

Pregunta 25

Pregunta
Gaseous chlorine is a
Respuesta
  • Clear colorless gas
  • White fog-like gas
  • Greenish-yellow gas
  • Greyish-white gas

Pregunta 26

Pregunta
In an aerator, a white billowing foam indicates
Respuesta
  • The need to increase wasting
  • The need to increase the return activated sludge rate
  • The need to decrease wasting
  • The need to stop the return activated sludge

Pregunta 27

Pregunta
In the aerator, the dissolved oxygen should be maintained at what level?
Respuesta
  • 2.0 mg/L
  • 5.0 mg/L
  • 6.0 mg/L
  • 8.0 mg/L

Pregunta 28

Pregunta
A low F/M ratio, high MCRT, low SVI, and high MLSS concentrations are all characteristic of
Respuesta
  • A bulking sludge
  • A young sludge
  • An old sludge
  • None of the answers

Pregunta 29

Pregunta
A Class D operator shall not be the lead/chief operator of more than ______ wastewater treatment plant(s) at any time.
Respuesta
  • 1
  • 2
  • 5
  • 10

Pregunta 30

Pregunta
Where chlorine is used for basic disinfection, a total chlorine residual of at least 0.5 mg/L shall be maintained after at least _____ minutes contact time at maximum daily flow.
Respuesta
  • 15
  • 30
  • 45
  • 60

Pregunta 31

Pregunta
The operator must report the FDEP any serious breakdown or malfunction within what time frame?
Respuesta
  • 24 hours
  • 48 hours
  • 12 hours
  • Immediately

Pregunta 32

Pregunta
The recommended storage temperature for preserving samples is
Respuesta
  • 21° C
  • 4° C
  • 60° F
  • 32° F

Pregunta 33

Pregunta
Employee hazards you might encounter around a treatment facility would be
Respuesta
  • Noxious or toxic gases
  • Physical injuries
  • Oxygen deficiency
  • All of the answers

Pregunta 34

Pregunta
Chlorine gas is
Respuesta
  • Colorless
  • Heavier than air
  • Nontoxic
  • Odorless

Pregunta 35

Pregunta
Chlorine is primarily used to
Respuesta
  • Disinfect
  • Prevent corrosion
  • Raise pH
  • Stabilize organics

Pregunta 36

Pregunta
The exhaust fan inlet in a chlorinator room and/or chlorine storage room should be taken from
Respuesta
  • Anywhere - the location is not important
  • At floor level
  • Close to the entrance
  • In the ceiling
Mostrar resumen completo Ocultar resumen completo

Similar

Operation of Wastewater Treatment Plants Volume 2 Review
Dean Lampman
General Wastewater Knowledge
Dean Lampman
Países de Latinoamérica y sus Capitales
maya velasquez
La Escala Musical
mariajesus camino
EXAMEN DE MATEMATICAS PRIMER GRADO SECUNDARIA
FELIPE SOLTERO
LAS BACTERIAS
ARMANDO SILVA PACHECO
RESOLUCIÓN DE CONFLICTOS
Kelly Maria
INGENIERÍA CIVÍL QUÍMICA
camila.bertiola
constitucion de una empresa
isabel escobar