According to FDEP chapter 62-600.440 (4)(b) FAC, basic level disinfection is described as:
Respuesta
  • A chlorine residual of 0.5 mg/L for 30 minutes at peak hourly flow
  • A chlorine residual of 1.0 mg/L for 15 minutes at peak hourly flow
  • A chlorine residual of 0.5 mg/L for 15 minutes at peak hourly
  • A chlorine residual of 0.5 mg/L for 30 minutes at average daily flow

Pregunta 2

Pregunta
FDEP chapter 62-604.550 (a) FAC, requires a wastewater spill shall be verbally reported to the state warning point no later than:
Respuesta
  • 8 hours from discovery
  • 12 hours from discovery
  • 24 hours from discovery
  • 72 hours from discovery

Pregunta 3

Pregunta
According to FDEP chapter 62-601, FAC, a composite sample shall be used for which test?
Respuesta
  • Total chlorine residual
  • Effluent CBOD
  • Effluent pH
  • Effluent fecal coliform

Pregunta 4

Pregunta
According to FDEP Chapter 62-602 FAC, an operator could have his/her license permanently revoked for
Respuesta
  • Falsified or misrepresented reports, logs or lab sheets
  • Cheating on an exam
  • Incompetence in operation of a wastewater treatment plant
  • Submitting false data on license application

Pregunta 5

Pregunta
According to Chapter 62-620 FAC, Wastewater Permitting, plant records must be maintained on-site for how many years?
Respuesta
  • One year
  • Three years
  • Five years
  • Forever

Pregunta 6

Pregunta
According to FDEP chapter 62-600.440 (4)(c) 4, basic level disinfection, any ONE sample may not exceed how many colonies per 100 ml sample?
Respuesta
  • 100
  • 200
  • 500
  • 800

Pregunta 7

Pregunta
Which FDEP rule describes requirements for high level disinfection?
Respuesta
  • Chapter 62-600 FAC, Domestic Wastewater Facilities
  • Chapter 62-602 FAC, Drinking Water and Wastewater Plant Operators
  • Chapter 62-640 FAC, Domestic Wastewater Residuals
  • Chapter 62-699 FAC, Treatment Plant Classification and Staffing

Pregunta 8

Pregunta
According to Chapter 62-600.440 (5) (f) FAC, regarding high level disinfection, any one sample shall not exceed how many fecal coliform values over a 30 day period?
Respuesta
  • 10 fecal coliform values per 100 ml sample
  • 25 fecal coliform values per 100 ml sample
  • 200 fecal coliform values per 100 ml sample
  • 800 fecal coliform values per 100 ml sample

Pregunta 9

Pregunta
Chapter 62-601, Domestic Wastewater Treatment Plant Monitoring, states that on-site tests for total residual chlorine, pH and __________________ can be performed under the direction of a certified operator:
Respuesta
  • Fecal coliform
  • CBOD
  • TSS
  • Dissolved Oxygen

Pregunta 10

Pregunta
These types of samples may be used for CBOD5 and nutrients at flows less than 100,000 GPD, according to Chapter 62-601
Respuesta
  • Spiked samples
  • Composite samples
  • Grab samples
  • Frozen samples

Pregunta 11

Pregunta
According to FDEP Chapter 62-602, Drinking Water and Wastewater Treatment Plant Operators, duties of operators includes reporting to the permittee and the Department, as soon as possible, but within 24 hours
Respuesta
  • Any major interruption of service
  • Identification of the plant
  • Oil change discrepancies
  • Excessive energy usage

Pregunta 12

Pregunta
According to Chapter 62-610.421 FAC, reuse of reclaimed water, the minimum setback distance for a slow-rate, land application systems shall be _____________ feet from the edge of wetted areas to buildings that are not part of the treatment system, or to the property line?
Respuesta
  • 50 feet
  • 75 feet
  • 100 feet
  • 250 feet

Pregunta 13

Pregunta
How many days, from the last day of application of reclaimed water, land application areas shall not be used for grazing of cattle whose milk is intended for human consumption? (FDEP Ch 62-610.425 FAC)
Respuesta
  • 5 days
  • 15 days
  • 30 days
  • 180 days

Pregunta 14

Pregunta
If this kind of disinfection is provided, the above rule does not apply: (FDEP Ch 62-610.425 FAC)
Respuesta
  • Basic level disinfection
  • Chlorine dioxide disinfection
  • High level disinfection
  • Ultraviolet disinfection

Pregunta 15

Pregunta
According to Chapter 62-640, Domestic Wastewater Residuals, the definition of a pathogen includes viruses, bacteria, protozoa and __________________?
Respuesta
  • Rat eggs
  • Viable helminth ova
  • Living nematode eggs
  • Viable helminth ova and Living nematode eggs

Pregunta 16

Pregunta
According to FDEP Chapter 62-610 FAC, the definition: “Water that has received at least secondary treatment and basic disinfection and is reused after flowing out of a domestic wastewater treatment facility” describes what?
Respuesta
  • Cooling water to a ice manufacturing facility
  • Reclaimed water
  • Distilled water
  • Golf course irrigation water

Pregunta 17

Pregunta
FDEP Chapter 62-620 FAC, Wastewater Facility Permitting, requires applications for permit renewal be submitted to the department ________________ days before the expiration of existing permit?
Respuesta
  • 30 days
  • 90 days
  • 180 days
  • 365 days

Pregunta 18

Pregunta
According to FDEP Chapter 62-601 FAC, Domestic Wastewater Treatment Plant Monitoring, discharge monitoring reports (DMRs) for the previous month must be submitted to the department by the ___________ day of the current month?
Respuesta
  • 10th
  • 12th
  • 25th
  • 28th

Pregunta 19

Pregunta
FDEP Chapter 62-600 FAC, Domestic Wastewater Facilities, states that all treatment plants shall be _________________?
Respuesta
  • Covered
  • Cleaned
  • Fenced
  • Painted

Pregunta 20

Pregunta
Chapter 62-601 FAC, Domestic Wastewater Treatment Plant Monitoring, states: “For systems involving high-level disinfection, compliance with the TSS limitation shall be achieved, and sampled for…”
Respuesta
  • After clarification, and before final filtration
  • After the filter, and before application of the disinfectant
  • After chlorination, and before de-chlorination
  • After the disinfectant, and before the filter
Mostrar resumen completo Ocultar resumen completo

Similar

First Certificate - Use of English Parte 3
Diego Santos
¿Qué sabes de Roma antígua? - EDUpunto.com
EDUpunto Por: Ernesto De Frías
PLASTICIDAD CEREBRAL
Kareen Gatica
HORARIO DE ESTUDIO (SEMANAL)
Vaaanesa1703
Properties of musical tones
Olga Veiga
constitucion de una empresa
isabel escobar
PRESENT SIMPLE 2 MULTIPLE CHOICE
Silvia Francisco Llorente
III. FORMACIÓN Y DESARROLLO PROFESIONAL DE LOS MAESTROS
DIRECCIÓN GENERAL DE EDUCACIÓN FISICA FEDERALIZADA
ARQUITECTURA DE COMPUTADORA
jose santos
TUBERCULOSIS
Mary Coronel
Foro 4_MAD
Itziar Arnelas