Central heating question time

Descripción

Test sobre Central heating question time, creado por gaby khalil el 08/02/2015.
gaby khalil
Test por gaby khalil, actualizado hace más de 1 año
gaby khalil
Creado por gaby khalil hace casi 10 años
55
3

Resumen del Recurso

Pregunta 1

Pregunta
What heating system is no longer approved by the Building Regulations?
Respuesta
  • Frost stat
  • Two-pipe fully pump system
  • fully pump One-pipe system
  • Gravity system

Pregunta 2

Pregunta
What is a fully pumped system?
Respuesta
  • The hot water and heating circuits are both operated by the pump.
  • Only the hot water circuit is operated by the pump.
  • Only the heating circuit is operated by the pump.
  • Only the hot water is operated by gravity circulation.

Pregunta 3

Pregunta
What is an advantage of a one-pipe system?
Respuesta
  • It takes a long time to install.
  • Higher temperatures are achieved.
  • It is quicker and cheaper to install
  • It is a naturally-balanced system.

Pregunta 4

Pregunta
What does a semi-gravity system with a two-port valve provide?
Respuesta
  • Adjustable flow rate
  • Easily balanced system
  • Automatic air venting
  • Independent temperature control of hot water and heating

Pregunta 5

Pregunta
How is the balancing of a system achieved?
Respuesta
  • By adjusting the pump
  • By adjusting the boiler temperature
  • By adjusting lock-shield valves
  • By adjusting by-pass valves

Pregunta 6

Pregunta
What does a two position three-port valve give priority to?
Respuesta
  • Domestic hot water circuit
  • The heating circuit
  • The TRVs
  • Fully pumped system

Pregunta 7

Pregunta
What is the mid-position three-port valve not suitable for?
Respuesta
  • Dwellings with floor areas greater than 150m2
  • Dwellings with floor areas less than 150m2
  • Dwellings with floor areas greater than 200m2
  • Dwellings with floor areas less than 20m2

Pregunta 8

Pregunta
What is a programmable room thermostat?
Respuesta
  • A combined time switch and room thermostat
  • A frost and room thermostat combined
  • A boiler and room thermostat combined
  • All of the above

Pregunta 9

Pregunta
What is the maximum flow rate for a domestic heating pump?
Respuesta
  • 2 l/s
  • 3 l/s
  • 4 l/s
  • 1.5 l/s

Pregunta 10

Pregunta
What is the purpose of an air separator?
Respuesta
  • To remove dirt from the system
  • To remove turbulence from the system
  • To remove air from the system
  • To separate the oxygen from the hydrogen
Mostrar resumen completo Ocultar resumen completo

Similar

Mapa Mental para Resumir y Conectar Ideas
Diego Santos
ENFERMERÍA HOSPITALARIA
celuzcabascango
EXAMEN DE MATEMATICAS PRIMER GRADO SECUNDARIA
FELIPE SOLTERO
Test ICFES Inglés Parte 1
colrobomoyp
Grupos funcionales (Bioquímica)
Nadim Bissar
Relación del Derecho Mercantil con otras ramas del Derecho
Juan Jose Avila Espinoza
Tipos De Argumentos
Raul Henderson
Cáncer de Páncreas
Miriam Aguirre O
Sistemas economicos
Bringas v
English Vocabulary: Money
Diego Santos
Mapa de navegación UNIMINUTO
Alejandro Dueñas