Unit 203 Mock Installation Technology Questions

Resumen del Recurso

Pregunta 1

Pregunta
Which one of the following directly affects all persons working with electricity in a working environment?
Respuesta
  • Electricity Safety, Quality and Continuity Regulations
  • BS 7671
  • Electricity at Work Regulations
  • Construction design and management Regulations

Pregunta 2

Pregunta
Which one of the following are non-statutory regulations?
Respuesta
  • Electricity at Work Regulation
  • Manual Handling Regulation
  • BS 7671
  • Provision and Use of Work Equipment Regulations

Pregunta 3

Pregunta
Which one of the following is a direct implication of not complying with statutory regulations?
Respuesta
  • Loss of earnings
  • Lost clients
  • Dismissal
  • Prosecution

Pregunta 4

Pregunta
The document showing the location of electrical equipment in an electrical installation is a:
Respuesta
  • specification
  • drawing
  • variation order
  • Gantt chart

Pregunta 5

Pregunta
Which one of the following diagram types does not show individual conductors or cables but shows the sequence of equipment?
Respuesta
  • Block
  • Circuit
  • Schematic
  • Bar chart

Pregunta 6

Pregunta
The symbol shown represents:
Respuesta
  • one-way switch
  • two-way switch
  • intermediate switch
  • pull switch

Pregunta 7

Pregunta
Which one of the following is the correct drawing scale where a wall, 4m in length, measures 8cm on a drawing?
Respuesta
  • 1:50
  • 1:100
  • 1:200
  • 1:500

Pregunta 8

Pregunta
A drawing is produced to a scale of 1:50 showing a socket outlet installed 3.5cm from the corner of a room. Which one of the following is the actual distance from the corner in the room?
Respuesta
  • 0.875m
  • 1.75m
  • 3.5m
  • 7m

Pregunta 9

Pregunta
A circuit installed to supply a fire panel would be identified as:
Respuesta
  • power and heating
  • data communication
  • control circuit
  • alarm and emergency system

Pregunta 10

Pregunta
The type of trunking that can be used as a circuit protective conductor is:
Respuesta
  • mini
  • PVC dado
  • steel
  • plastic

Pregunta 11

Pregunta
The insulation material of mineral insulated metal sheathed cables is absorbent; therefore the terminations must be:
Respuesta
  • watertight
  • correctly identified
  • fitted with a gland
  • fitted with a shroud

Pregunta 12

Pregunta
Additional cable supports should be provided in trunking where:
Respuesta
  • segregation is required
  • there are long vertical runs
  • trunking is made of plastic
  • the walls are made of lightweight block

Pregunta 13

Pregunta
Band I and Band II circuits can be enclosed in the same enclosure, provided that:
Respuesta
  • the current rating of all circuits does not exceed 10A
  • they are twisted around each other along the trunking length
  • every cable or conductor is insulated for the highest voltage present
  • there are the same number of Band I and Band II circuits

Pregunta 14

Pregunta
Which one of the following is the type of conduit fixing shown?
Respuesta
  • Cleat
  • Clip
  • Crampet
  • Saddle

Pregunta 15

Pregunta
Which one of the following symbols represents the rating factor for thermal insulation?
Respuesta
  • Ci
  • Ca
  • Cf
  • Cg

Pregunta 16

Pregunta
Which one of the following is the value of voltage drop, per ampere, per metre, for a 10mm2 multi-core flat thermoplastic 70°C cable, intended to supply a single phase circuit?
Respuesta
  • 44 mV/A/m
  • 11 mV/A/m
  • 4.4 mV/A/m
  • 2.8 mV/A/m

Pregunta 17

Pregunta
Which one of the following is the maximum current carrying capacity for a single core 6mm2 70°C thermoplastic insulated non armoured cable, enclosed in conduit on a wall installed for a single phase circuit?
Respuesta
  • 31A
  • 32A
  • 36A
  • 41A

Pregunta 18

Pregunta
Which one of the following is the value of voltage drop, in millivolts per ampere per metre, for a 4mm2 multi core thermosetting non armoured cable, intended to supply a single phase circuit?
Respuesta
  • 29 mV/A/m
  • 18 mV/A/m
  • 11 mV/A/m
  • 7.3 mV/A/m

Pregunta 19

Pregunta
Which one of the following devices is suitable for an installation supplying an X-ray machine in a hospital?
Respuesta
  • BS 3036 rewireable fuse
  • BS EN 60898 Type D
  • BS EN 60898 Type C
  • BS EN 60898 Type B

Pregunta 20

Pregunta
Which one of the following devices will disconnect in the fastest time if a short circuit current of approximately 400A occurred on a circuit?
Respuesta
  • 32A/30mA Type C RCBO
  • 32A Type B circuit breaker
  • 32A Type C circuit breaker
  • 32A Type D circuit breaker

Pregunta 21

Pregunta
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: • 4 x 1.5mm2 • 3 x 2.5mm2?
Respuesta
  • 16mm
  • 20mm
  • 25mm
  • 32mm

Pregunta 22

Pregunta
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: • 8 x 1.5mm2 • 2 x 2.5mm2 • 2 x 4.0mm2?
Respuesta
  • 16mm
  • 20mm
  • 25mm
  • 32mm

Pregunta 23

Pregunta
Which one of the following is the conduit capacity factor to be used where a 25mm conduit has 2 bend in a 6m run?
Respuesta
  • 111
  • 182
  • 333
  • 600

Pregunta 24

Pregunta
The electrical system in which the connection to earth is by an earth electrode is:
Respuesta
  • TT
  • TN-S
  • TN-C
  • TN-C-S

Pregunta 25

Pregunta
Which one of the following earthing arrangements is shown in the diagram?
Respuesta
  • TN-C-S
  • TT
  • TN-C
  • TN-S

Pregunta 26

Pregunta
Which one of the following is the correct name of the component which links the main earthing terminal of an installation to the means of earthing?
Respuesta
  • Main protective bonding conductor
  • Supplementary equipotential bond
  • Earthing conductor
  • Functional earth

Pregunta 27

Pregunta
What is represented by Zs in the following formula: Zs = Ze + (R1 + R2)?
Respuesta
  • Total earth fault loop impedance
  • External earth fault loop impedance
  • Final circuit earth fault loop impedance
  • Combined resistance of the earth path

Pregunta 28

Pregunta
Which one of the following defines the term ‘main protective bonding conductor’?
Respuesta
  • The conductor which links the MET to an earth electrode
  • The conductor which links the MET to extraneous conductive parts
  • The conductor which links the MET to exposed conductive parts
  • The conductor which links the MET to the means of earthing

Pregunta 29

Pregunta
Which one of the following is the purpose of the main protective bonding conductor?
Respuesta
  • To raise extraneous conductive parts to the same voltage as the supply under overload
  • To raise extraneous conductive parts to the same voltage as the supply under earth fault conditions
  • To raise extraneous conductive parts to the same voltage as the supply under normal conditions
  • To raise extraneous conductive parts to the same voltage as the supply under transient fault conditions

Pregunta 30

Pregunta
Which one of the following is an exposed conductive part?
Respuesta
  • Metal-clad switch
  • Structural steelwork
  • Air conditioning ducting
  • Metallic oil service pipe

Pregunta 31

Pregunta
Which one of the following is metal cable trunking?
Respuesta
  • Earthed conductive part
  • Extraneous conductive part
  • Insulated part
  • Exposed conductive part

Pregunta 32

Pregunta
Which one of the following is an extraneous conductive part?
Respuesta
  • Metallic gas service pipe
  • Metal-clad twin socket outlet
  • Heavy duty steel conduit
  • PVC mini-trunking

Pregunta 33

Pregunta
Which one of the following methods of generating electricity uses fossil fuels?
Respuesta
  • Wave power
  • Solar
  • Gas
  • Wind

Pregunta 34

Pregunta
Which one of the following uses sunlight to generate electricity?
Respuesta
  • Photo-voltaic
  • Biomass
  • Wind
  • Air source heat pump

Pregunta 35

Pregunta
Which one of the following is a transmission voltage?
Respuesta
  • 400kV
  • 33kV
  • 11kV
  • 400V

Pregunta 36

Pregunta
Which one of the following is a typical distribution voltage for a medium-sized factory where a private sub station is located?
Respuesta
  • 230V
  • 400V
  • 5kV
  • 11kV

Pregunta 37

Pregunta
In which of the following parts of the electrical distribution network would a step-down transformer be located?
Respuesta
  • Power station
  • Pylon
  • Local distribution sub station
  • Inverter

Pregunta 38

Pregunta
Which one of the following describes the process of a solar photo voltaic system?
Respuesta
  • Solar power is used to ignite a biomass which heats up water
  • Solar power is collected by a solar panel which provides electricity
  • Solar power is collected by a solar panel which provides hot water
  • Solar power causes hot air to rise, rotating a generator that produces electricity

Pregunta 39

Pregunta
Which one of the following is a suitable use for rainwater harvesting?
Respuesta
  • Baths/showers
  • Toilet flushing
  • Drinking water
  • Cooking water

Pregunta 40

Pregunta
Which one of the following micro-generation systems requires the least maintenance once installed?
Respuesta
  • Micro-combined heat and power
  • Air source heat pump
  • Biomass
  • Solar thermal
Mostrar resumen completo Ocultar resumen completo

Similar

Unit 203 Revision: Installation Technology Question Bank No.1
Oliver Balay
Unit 203 Revision: Installation Technology Question Bank No.1
Jamie Parslow-Williams
Unit 203 Revision: Installation Technology Question Bank No.1
james seaman
Unit 203 Revision: Installation Technology Question Bank No.1
dave love
Unit 203 Revision Question Bank No.2
Oliver Balay
Unit 308 Careeer's Awareness Revision
Oliver Balay
Unit 203 Revision Question Bank No.2
carl tovey
Unit 203 Revision: Installation Technology Question Bank No.1
Jamie Parslow-Williams
Unit 203 Revision: Installation Technology Question Bank No.1
Derek Pitcher
Unit 203 Revision: Installation Technology Question Bank No.1
Chantelle Browne
Unit 203 Revision: Installation Technology Question Bank No.1
Kourosh Savarnik