Pregunta 1

Pregunta
What would be the fire resistance requirement of a mechanical shaft connecting the 5 stories of a new office building?
Respuesta
  • 3-hour fire-resistance
  • 2-hour fire-resistance
  • 1-hour fire-resistance
  • None of the above

Pregunta 2

Pregunta
According to the 2018 IBC, what is the minimum number of intermediate landings of an egress stair, necessary to connect 2 floors with an elevation difference of 25′-0″?
Respuesta
  • 1
  • 2
  • 3
  • 4

Pregunta 3

Pregunta
Which of the following are examples of organizations that develop standards? Check all that apply.
Respuesta
  • American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)
  • The National Fire Protection Association (NFPA)
  • American Iron and Steel Institute (AISI)
  • The American National Standards Institute (ANSI)
  • ASTM International

Pregunta 4

Pregunta
According to the 2018 IBC, which of the following is a Class B material?
Respuesta
  • Flame spread index - 23 Smoke-developed index - 350
  • Flame spread index - 27 Smoke-developed index - 50
  • Flame spread index - 81 Smoke-developed index - 400
  • Flame spread index - 95 Smoke-developed index - 25

Pregunta 5

Pregunta
Which of the following changes in level are not ADA compliant? Check the two that apply.
Respuesta
  • 1/4 " vertical change
  • 1/2 " change with a 1:2 bevel
  • 1/3 " change with a 1:2 bevel
  • 1/3" vertical change
  • 1/2 " change with a 3:4 bevel
  • 1/4 " change with a 1:4 bevel

Pregunta 6

Pregunta
Which of the following materials would have the highest FSI after being submitted to ASTM E84 testing?
Respuesta
  • Brick
  • Gypsum Wallboard
  • Gypsum Sheathing
  • White Oak

Pregunta 7

Pregunta
Per the 2010 ADA Standards, what are the minimum maneuvering clearances missing in the image below?
Respuesta
  • 50" and 24"
  • 48" and 24"
  • 42" and 22"
  • 48" and 18"

Pregunta 8

Pregunta
How would an accessory occupancy typically be separated from the main occupancy?
Respuesta
  • No separation is required
  • 1-Hour fire barrier
  • 2-Hour fire barrier
  • 1-Hour fire barrier or sprinkler system

Pregunta 9

Pregunta
Based on the table below, how many accessible parking stalls are required on a 466,900-sf parking lot? Assume an overall efficiency of 350 sf per parking space.
Respuesta
  • 20
  • 24
  • 28
  • 32

Pregunta 10

Pregunta
Which of the following sentences are correct? Check all that apply.
Respuesta
  • Doors in any position shall not reduce the required egress width by more than one-half
  • Doors, when fully opened, shall not reduce the required egress width by more than 7"
  • Doors in any position shall not reduce the required egress width by more than one-third
  • Doors, when fully opened, shall not reduce the required egress width by more than 4"
  • Wall mounted fixtures, at a height of 70", shall not project horizontally from either side more than 4"
  • Wall mounted fixtures, at a height of 70", shall not project horizontally from either side more than 7"
Mostrar resumen completo Ocultar resumen completo

Similar

PDD Quiz XII
a a
PDD Quiz I
a a
Gestión de Proyectos
Maye Tapia
Banderas
Diego Santos
Criterios generales de evaluación de la Selectividad: Comentarios de Texto
maya velasquez
Bioquímica
ausdauer_faith
Lección de Inglés: Nivel Intermedio
Diego Santos
Razonamiento lógico
Liz García
Cómo Usar Fichas para Mejorar el Aprendizaje de tus Alumnos
Diego Santos
2.2 LOS MEDIOS DE TELECOMUNICACIONES I
antonio del valle
Concepción Pedagogia y Didáctica
NEIL BERNAL R.