Pregunta 1

Pregunta
What type of system consists of cables that were installed in an air-handling space prior to mandated use of cables that meet the flame-spread and smoke-index requirements of codes, standards & regulations?
Respuesta
  • Grandfathered System
  • Abandoned cable System
  • Riser Cable System
  • Non-Plenum Cable System

Pregunta 2

Pregunta
What are the 2 key components of an optical fiber?
Respuesta
  • Core & Cladding
  • Core & Acrylate
  • Cladding & Acrylate
  • Core & Buffer

Pregunta 3

Pregunta
The [blank_start]F Rating[blank_end] is the amount of time in hours the firestopping system can prevent flames from passing through the system.
Respuesta
  • F Rating
  • T Rating
  • L Rating

Pregunta 4

Pregunta
This is the establishment of a reference for the electrical power source (AC or DC), electrical equipment or both
Respuesta
  • Grounding
  • Bonding
  • Electrode System
  • TMGB

Pregunta 5

Pregunta
The [blank_start]L Rating[blank_end] indicates a firestops ability to provide an effective smoke seal.
Respuesta
  • L Rating
  • F Rating
  • T Rating

Pregunta 6

Pregunta
This provides a quick graphical representation of how a circuit is laid out
Respuesta
  • Circuit Layout Record
  • Cutover Plan
  • As-built

Pregunta 7

Pregunta
A Consolidation Point (CP) should serve up to 24 work areas?
Respuesta
  • True
  • False

Pregunta 8

Pregunta
How many walls of a TR should have fire-retardant plywood?
Respuesta
  • 2
  • 1
  • 3
  • 4

Pregunta 9

Pregunta
Cross-Connect Field Colors: Second-Level Backbone
Respuesta
  • Gray
  • Orange
  • White
  • Brown

Pregunta 10

Pregunta
All ferrous metal pathways must be bonded at both ends regardless of length when containing a bonding conductor?
Respuesta
  • True
  • False

Pregunta 11

Pregunta
This amount of current will cause breathing to become difficult
Respuesta
  • 2-3mA
  • 10mA
  • 50-100mA
  • 100mA

Pregunta 12

Pregunta
Who's responsibility is it to provide safety training for its employees?
Respuesta
  • Employee's Organization
  • Employee
  • OHSA
  • Customer

Pregunta 13

Pregunta
Widening or spreading out of modes in a light pulse as it progresses along the optical fiber
Respuesta
  • Dispersion
  • Core
  • Photons
  • Modal Bandwidth

Pregunta 14

Pregunta
This type of cutover is one continuous process until competed
Respuesta
  • Flash Cutover
  • Phased Cutover
  • Complete Shutdown
  • Continuous Cutover

Pregunta 15

Pregunta
This type of backbone cabling distributes telecommunications services between telecommunications spaces within a single building
Respuesta
  • Intrabuilding
  • Interbuilding
  • Fiber Optic

Pregunta 16

Pregunta
What is the width of the TMGB
Respuesta
  • 3.94 inches
  • 3.95 inches
  • 3.93 inches
  • 4 inches

Pregunta 17

Pregunta
The ITS installer can substitute products that are not part of the qualified firestop assembly
Respuesta
  • True
  • False

Pregunta 18

Pregunta
This firestop is used primarily for large air handling & exhaust vents
Respuesta
  • Blankets
  • Spray
  • Pillows
  • Foam

Pregunta 19

Pregunta
This type of cutover procedure has portions of the old system transferred to the new system in groups
Respuesta
  • Flash Cutover
  • Phased Cutover
  • Staged Cutover
  • Continuous Cutover

Pregunta 20

Pregunta
What is the information carrying capacity of a system
Respuesta
  • Bandwidth
  • Megabit
  • Megahertz
  • Decibel

Pregunta 21

Pregunta
What is the maximum length of FMT
Respuesta
  • 20 feet
  • 10 feet
  • 15 feet
  • 25 feet

Pregunta 22

Pregunta
26 AWG has ______ more attenuation
Respuesta
  • 50%
  • 20%
  • 30%
  • 40%

Pregunta 23

Pregunta
This is the copper conductor that interconnects the TMGB to TGB
Respuesta
  • TBB
  • GE
  • TEBC
  • ACEG

Pregunta 24

Pregunta
Cross-Connect Field Colors: Network Connections
Respuesta
  • Green
  • Blue
  • Purple
  • Yellow

Pregunta 25

Pregunta
Who should the ITS installer seek guidance from for minimum safety requirements for safe work & employee health
Respuesta
  • AHJ
  • Employer
  • OHSA
  • Safety Director

Pregunta 26

Pregunta
What is the recommended maximum value for the bonding resistance between any 2 points where bonding exists
Respuesta
  • 0.1 Ohms
  • 1 Ohm
  • 10 Ohms
  • 0.01 Ohms

Pregunta 27

Pregunta
The refractive index of the fiber core is higher than that of the cladding
Respuesta
  • True
  • False

Pregunta 28

Pregunta
This type of backbone consists of cabling that is installed between a MC and IC/HC
Respuesta
  • First Level
  • Second Level
  • Interbuilding
  • Fiber Optic

Pregunta 29

Pregunta
This is a result from different optical fiber lengths in multimode fiber
Respuesta
  • Overfill Launch
  • Modal Dispersion
  • Modal Bandwidth

Pregunta 30

Pregunta
This type of protector is used to protect against sneak current
Respuesta
  • Primary
  • Secondary
  • Data & Fire Alarm
  • Carbon

Pregunta 31

Pregunta
Abandoned cable can become fuel and is a fire hazard
Respuesta
  • True
  • False

Pregunta 32

Pregunta
Cross-Connect Field Colors: First Level Backbone
Respuesta
  • White
  • Gray
  • Brown
  • Blue

Pregunta 33

Pregunta
Why is copper a preferred conductor (select all correct)
Respuesta
  • Economical
  • Offers less resitance
  • Readily available
  • Easy to produce

Pregunta 34

Pregunta
This type of protector has a reaction time of 3-5ns
Respuesta
  • Gas
  • Carbon
  • Solid State
  • Primary

Pregunta 35

Pregunta
The results of a __________ will be used to develop the project schedule and the installation job plan
Respuesta
  • Site survey
  • Scope of work
  • Specification

Pregunta 36

Pregunta
Humans can hear in what frequency range
Respuesta
  • 20-20,000Hz
  • 20-20,000MHz
  • 20-2,000Hz
  • 20-2,000MHz

Pregunta 37

Pregunta
A micrometer is
Respuesta
  • 1 billionth of a meter
  • 1 thousandth of a meter
  • 1 millionth of a meter

Pregunta 38

Pregunta
The primary responsibility of the ___________ is safeguarding personnel, property and equipment from foreign electrical voltages and current
Respuesta
  • ITS Installer
  • Qualified Electrican

Pregunta 39

Pregunta
When personnel are relocated into temporary office space during retrofits
Respuesta
  • Temporary Space
  • Swing-space Phasing
  • Project Relocation

Pregunta 40

Pregunta
When are GFCIs required (select all correct)
Respuesta
  • with temporary electrical wiring
  • extension cords
  • in Data Centers

Pregunta 41

Pregunta
What is the movement of information in the form of electrical or optical signals from one point to another through a transport medium
Respuesta
  • Transmission
  • Signal Transfer
  • Attenuation
  • Propagation Delay

Pregunta 42

Pregunta
More deaths result from flames rather than smoke and toxic gases
Respuesta
  • True
  • False

Pregunta 43

Pregunta
What does OSHA have the authority to do (select all correct)
Respuesta
  • Develop, publish & enforce safety regulations
  • Shut down unsafe job site
  • Levy fines against individuals and companies
  • confiscate tools and equipment

Pregunta 44

Pregunta
The [blank_start]T Rating[blank_end] is the amount of time in hours the firestopping system can keep the temperature from rising above a specified point
Respuesta
  • T Rating
  • F Rating
  • L Rating

Pregunta 45

Pregunta
List 3 distinct, yet interconnected grounding systems (Select all correct)
Respuesta
  • AC Grounding Electrode System
  • Equipment Grounding System
  • Telecommunications Bonding Infrastructure
  • Supplemental Ground System

Pregunta 46

Pregunta
1 cycle in 1 second = ?
Respuesta
  • 1Hz
  • 100Hz
  • 10Hz
  • 1MHz

Pregunta 47

Pregunta
Which fiber is most common for backbone & horizontal runs within buildings and campus environments
Respuesta
  • Multimode
  • Singlemode
  • OM2
  • OM1

Pregunta 48

Pregunta
If expanding a TR, what must be done prior to removing the wall with equipment/hardware
Respuesta
  • Float the backboard
  • Hang the backboard
  • temporarily support the backboard

Pregunta 49

Pregunta
What type of ladder is not allowed to be used by an ITS installer
Respuesta
  • Aluminum
  • Wood
  • Extension
  • Fiberglass

Pregunta 50

Pregunta
What is the diameter of the cladding in multimode fiber cable
Respuesta
  • 50um
  • 125um
  • 62.5um
  • 250um

Pregunta 51

Pregunta
What is the distance limitation of multimode fiber
Respuesta
  • 2,000 meters
  • 3,000 meters
  • 1,000 meters
  • 10,000 meters

Pregunta 52

Pregunta
If an extension ladder is extended 24ft up, then how far should the base be out
Respuesta
  • 5ft
  • 4ft
  • 6ft
  • 8ft

Pregunta 53

Pregunta
Which transmission method transmits a signal in one direction only
Respuesta
  • Simplex
  • Full Duplex
  • Half Duplex

Pregunta 54

Pregunta
It is acceptable to use a TE in place of a TR
Respuesta
  • True
  • False

Pregunta 55

Pregunta
Which fiber supports wavelengths of 1310nm, 1490nm, 1550nm & 1625nm
Respuesta
  • Singlemode
  • Multimode

Pregunta 56

Pregunta
What is the minimum size of stub up conduits
Respuesta
  • 3/4"
  • 1/2"
  • 1"
  • 7/8"

Pregunta 57

Pregunta
How many rungs need to overlap when extending an extension ladder
Respuesta
  • 3
  • 2
  • 4
  • 5

Pregunta 58

Pregunta
What is the measure of analog signal strength
Respuesta
  • Bit
  • Bel
  • Volt
  • Watt

Pregunta 59

Pregunta
How far should an extension ladder extend above a work area
Respuesta
  • 3ft
  • 2ft
  • 4ft
  • 3m

Pregunta 60

Pregunta
This current will trigger ventricular fibrillation, which causes the heart to repeatedly relax and violently clamp shut (usually results in death)
Respuesta
  • 100mA
  • 200mA
  • 50mA
  • 50-100mA

Pregunta 61

Pregunta
One of the primary functions of the ____________ is to house the floor-serving cross-connections and interconnection
Respuesta
  • TR
  • ER
  • TE
  • EF

Pregunta 62

Pregunta
What is the distance limitation of singlemode fiber
Respuesta
  • 2,000 meters
  • 3,000 meters
  • 5,000 meters
  • 10,000 meters

Pregunta 63

Pregunta
___________ are not dependent on ITS installers
Respuesta
  • Customers
  • Employees
  • IT Professionals

Pregunta 64

Pregunta
How far must an ITS installer stay away from exposed energized circuits operating at 300-50,000 volts
Respuesta
  • 10ft
  • 12ft
  • 6ft
  • 8ft

Pregunta 65

Pregunta
Which fiber supports wavelengths of 850nm and 1300nm
Respuesta
  • Multimode
  • Singlemode

Pregunta 66

Pregunta
What the 3 distinct ways in which others perceive and employee (select all correct)
Respuesta
  • Body language
  • Tone of voice
  • Choice of words
  • Facial expressions

Pregunta 67

Pregunta
Chin straps are not allowed to be used with hardhats
Respuesta
  • True
  • False

Pregunta 68

Pregunta
What is the most common fire protection principle
Respuesta
  • Compartmentation
  • Suppression
  • Detection

Pregunta 69

Pregunta
Which fiber generally uses LED and VCSEL light sources
Respuesta
  • Multimode
  • Singlemode

Pregunta 70

Pregunta
What is the diameter of the acrylate coating in fiber cable
Respuesta
  • 50um
  • 125um
  • 250um
  • 100um

Pregunta 71

Pregunta
What is the typical lifespan of a hard hat
Respuesta
  • 5 years
  • 1 year
  • 3 years
  • 2 years

Pregunta 72

Pregunta
What is the most common tight buffer diameter
Respuesta
  • 900um
  • 250um
  • 3mm

Pregunta 73

Pregunta
Tone of voice is ____% of communication perceptions
Respuesta
  • 7%
  • 38%
  • 55%

Pregunta 74

Pregunta
If using a MUTOA, what is the maximum length of a 24AWG, stranded work area cable if the horizontal cable is 70 meters
Respuesta
  • 22 meters
  • 25 meters
  • 5 meters
  • 27 meters

Pregunta 75

Pregunta
Which method transmits in either direction but in only 1 direction at a time
Respuesta
  • Simplex
  • Half duplex
  • Full duplex

Pregunta 76

Pregunta
Stickers are allowed to be placed on hard hats
Respuesta
  • True
  • False

Pregunta 77

Pregunta
Tight buffer fiber is only installed in multimode fiber
Respuesta
  • True
  • False

Pregunta 78

Pregunta
What is the maximum amount of moisture allowed in plywood backboards
Respuesta
  • 15%
  • 20%
  • 5%
  • 10%

Pregunta 79

Pregunta
Which type of fiber requires a furcation kit
Respuesta
  • Tight Buffer
  • Multimode
  • Loose Tube
  • Singlemode

Pregunta 80

Pregunta
Select all approved eye protection
Respuesta
  • Glasses
  • Goggles
  • Full Face Shield

Pregunta 81

Pregunta
This type of fiber consists of up to 24 strands bundled together in a single line that is color coded
Respuesta
  • Ribbon
  • Air blown
  • Tight buffer
  • Loose tube

Pregunta 82

Pregunta
These are to be installed on exposed circuits as near as possible to the point at which the exposed cables enter the bulding
Respuesta
  • Primary Protection
  • Secondary Protection
  • Data & Fire Alarm Protector

Pregunta 83

Pregunta
This firestop product is intumescent, metal back and used to seal large openings
Respuesta
  • sheets
  • putty
  • blankets
  • pads

Pregunta 84

Pregunta
This firestop material is a putty that is used to seal the back of outlet boxes
Respuesta
  • pads
  • sheets
  • wrap strips

Pregunta 85

Pregunta
This firestop material is intumescent used for plastic piping, insulated metal piping or cable bundles
Respuesta
  • wrap strips
  • putty
  • caulk

Pregunta 86

Pregunta
This firestop material is intumescent but mostly endothermic, soft and pliable. It comes in bars and sticks
Respuesta
  • putty
  • pads
  • foams

Pregunta 87

Pregunta
This firestop material can be intumescent, endothermic or ablative. It comes in tubes and can up to 2 weeks to to cure. It is used for permanent installations
Respuesta
  • caulk
  • putty
  • pillows

Pregunta 88

Pregunta
This firestop material is regarded as temporary and requires wire restraints to pass the hose test
Respuesta
  • pillows
  • putty
  • caulk

Pregunta 89

Pregunta
This firestop material incorporates putty and is referred to as a pipe choke system
Respuesta
  • collars
  • putty
  • foam

Pregunta 90

Pregunta
This firestop material may be intumescent, endothermic or ablative. It is a 2 part mixing with fast curing time
Respuesta
  • foam
  • sheets
  • blankets

Pregunta 91

Pregunta
Select the 3 types of centralized fiber cabling implementations
Respuesta
  • Pull-through
  • Interconnection
  • Splice in the TR
  • Home Run

Pregunta 92

Pregunta
This is a property of an electrical force field built around a conductor that opposes and changes in current flow in a circuit
Respuesta
  • Inductance
  • Capacitance
  • Resistance
  • Impedance

Pregunta 93

Pregunta
Words are _____% of communication perceptions
Respuesta
  • 7%
  • 38%
  • 55%

Pregunta 94

Pregunta
Air-blown systems are designed & manufactured for an expected operating lifetime of how many years
Respuesta
  • 20
  • 30
  • 10
  • 15

Pregunta 95

Pregunta
What refers to the amount of information that can be transported over the media
Respuesta
  • Megahertz
  • Megabit
  • Decibel

Pregunta 96

Pregunta
This current causes the heart the clamp shut and severe burns occur on the skin and hair
Respuesta
  • 100mA
  • 200mA
  • 50-100mA
  • 50mA

Pregunta 97

Pregunta
An ITS installer is allowed to leave a personnel lift with a safety belt with a non-locking keeper
Respuesta
  • True
  • False

Pregunta 98

Pregunta
Increasing the length of fiber or wavelength of the light source will decrease bandwidth
Respuesta
  • True
  • False

Pregunta 99

Pregunta
Open top cable supports are typically intended to support how many cables
Respuesta
  • 50
  • 20
  • 30
  • 40

Pregunta 100

Pregunta
Cross-Connect Field Colors: Miscellaneous
Respuesta
  • Yellow
  • Blue
  • Purple
  • Green

Pregunta 101

Pregunta
What is the basic unit of inductance
Respuesta
  • Henry
  • Watt
  • Farad
  • Ohm

Pregunta 102

Pregunta
There is no mandatory standard to identify the color coding for fiber
Respuesta
  • True
  • False

Pregunta 103

Pregunta
This firestop material is used in situations where a cable tray containing critical power or data cables must remain in operation during a fire
Respuesta
  • Blankets
  • Sprays
  • Pillows
  • Putties

Pregunta 104

Pregunta
According to standards, horizontal fiber cable is normally ____________
Respuesta
  • Multimode
  • Singlemode
  • Tight buffer
  • Loose tube

Pregunta 105

Pregunta
What is the minimum bend radius of a fiber cable, with up to 4 strands, during installation
Respuesta
  • 1 inch
  • 2 inch
  • 4 x diameter of cable
  • 10 x diameter of cable

Pregunta 106

Pregunta
What is the minimum bend radius of a fiber cable, with up to 4 strands, at rest
Respuesta
  • 1 inch
  • 2 inch
  • 4 x diameter of cable
  • 10 x diameter of cable

Pregunta 107

Pregunta
What is the minimum bend radius of interbuilding fiber during installation
Respuesta
  • 10 x diameter of cable
  • 15 x diameter of cable
  • 20 x diameter of cable

Pregunta 108

Pregunta
What is the minimum bend radius of a fiber backbone cable at rest
Respuesta
  • 15 x diameter
  • 10 x diameter
  • 20 x diameter

Pregunta 109

Pregunta
What is the minimum bend radius of an intrabuilding fiber during installation
Respuesta
  • 10 x diameter
  • 15 x diameter
  • 20 x diameter

Pregunta 110

Pregunta
Which test instruments can be used to test fiber while it is still on the reel (select all correct)
Respuesta
  • OLTS
  • VFL
  • OTDR

Pregunta 111

Pregunta
Which fiber test instrument does not require access to both ends of the fiber while testing on the reel
Respuesta
  • VFL
  • OTDR
  • OLTS

Pregunta 112

Pregunta
Bonding conductors are designed to intentionally carry AC ground fault current or lightning strike current
Respuesta
  • True
  • False

Pregunta 113

Pregunta
What is the maximum length for horizontal fiber runs
Respuesta
  • 90 meters
  • 100 meters
  • 2,000 meters
  • 3,000 meters

Pregunta 114

Pregunta
Lift belts give the user added strength
Respuesta
  • True
  • False

Pregunta 115

Pregunta
This administration addresses infrastructure with multiple buildings at a single site
Respuesta
  • Class 1
  • Class 2
  • Class 3
  • Class 4

Pregunta 116

Pregunta
It is recommended to order innerduct without a pull sting preisntalled
Respuesta
  • True
  • False

Pregunta 117

Pregunta
Select all approved types of hearing protection
Respuesta
  • Aural
  • Foam Earplugs (disposable)
  • Rubber Earplugs (reusable)

Pregunta 118

Pregunta
This type of protector has a reaction time of 15ns or more
Respuesta
  • Gas tubes
  • Solid state
  • Carbon blocks

Pregunta 119

Pregunta
This is the property of conductors that allows storage of electric charges when potential differences exist between conductors
Respuesta
  • Capacitance
  • Inductance
  • Resistance
  • Impedance

Pregunta 120

Pregunta
Body language is ______% of communication perceptions
Respuesta
  • 7%
  • 38%
  • 55%

Pregunta 121

Pregunta
This firestop material will develop a hard char that resists erosion from fire and flames
Respuesta
  • Ablative
  • Intumescent
  • Endothermic

Pregunta 122

Pregunta
This administration addresses infrastructure with one or more telecommunication spaces in a single building
Respuesta
  • Class 1
  • Class 2
  • Class 3
  • Class 4

Pregunta 123

Pregunta
Fall protection is required at which height
Respuesta
  • 4ft
  • 5ft
  • 3ft
  • 6ft

Pregunta 124

Pregunta
Which is the required physical topology for SCS
Respuesta
  • Star
  • Ring
  • Bus

Pregunta 125

Pregunta
(2) 1.5 inch and (1) 1 inch innerducts are recommended to be placed inside what size conduit
Respuesta
  • 3 inch
  • 2 inch
  • 4 inch
  • 6 inch

Pregunta 126

Pregunta
Cross-Connect Field Colors: Horizontal Cable
Respuesta
  • Blue
  • Green
  • Yellow
  • Orange

Pregunta 127

Pregunta
A PFAS (personal fall arrest system) includes a full body harness, a shock absorbing lanyard & secure anchorage point capable of supporting ______ pounds
Respuesta
  • 2,500lbs
  • 5,000lbs
  • 3,000lbs
  • 1,000lbs

Pregunta 128

Pregunta
The service loop is used to relieve all tension of the fiber cable
Respuesta
  • True
  • False

Pregunta 129

Pregunta
What is allowed to be used to mend torn clothing
Respuesta
  • duct tape
  • electrical tape
  • tie wraps

Pregunta 130

Pregunta
How much horizontal fiber should be left at the work area
Respuesta
  • 1 meter
  • 2 feet
  • 18 inches
  • 12 inches

Pregunta 131

Pregunta
How much fiber slack should be left in a cabinet within a TR
Respuesta
  • 10 meters
  • 3 feet
  • 1 meter
  • 3 meters

Pregunta 132

Pregunta
Capacitance is measured in ________
Respuesta
  • Farads
  • Henry
  • Ohm
  • Watts

Pregunta 133

Pregunta
Plywood backboards should be mounted at _____ AFF
Respuesta
  • 8 inches
  • 12 inches
  • 6 inches
  • 18 inches

Pregunta 134

Pregunta
This current will produce a tingling of the skin
Respuesta
  • 2-3mA
  • 10mA
  • 50-100mA
  • 50mA

Pregunta 135

Pregunta
When blowing fiber, what carries the cable down the tube
Respuesta
  • fluid drag
  • air pressure
  • vacuum

Pregunta 136

Pregunta
What describes the amount of information a fiber is capable of transporting
Respuesta
  • Modal Bandwidth
  • Dispersion
  • Megahertz

Pregunta 137

Pregunta
Which method transmits a signal in both directions at the same time
Respuesta
  • Full duplex
  • Half duplex
  • Simplex

Pregunta 138

Pregunta
What type of entrance pathway preserves the aesthetic appearance of the building and is economical over the life cycle
Respuesta
  • Underground
  • Buried
  • Aerial
  • Wireless

Pregunta 139

Pregunta
Air blown fiber shall not be used for outside plant
Respuesta
  • True
  • False

Pregunta 140

Pregunta
This administration addresses infrastructure with multiple sites or campuses
Respuesta
  • Class 1
  • Class 2
  • Class 3
  • Class 4

Pregunta 141

Pregunta
This current will produce a painful shock and muscles can't release the contact
Respuesta
  • 10mA
  • 2-3mA
  • 50mA
  • 100mA

Pregunta 142

Pregunta
Which of the following are basic tests to verify each tube prior to blowing fiber (select all correct)
Respuesta
  • airflow testing
  • pressure testing
  • continuity testing

Pregunta 143

Pregunta
This is required on every 3rd floor and top floor of a multi-story building that has multiple ER/TRs on the same floor
Respuesta
  • GE
  • TGB
  • TEBC
  • GEC

Pregunta 144

Pregunta
This serves as the dedicated extension of the building AC grounding electrode system of the telecommunications infrastructure
Respuesta
  • TMGB
  • TGB
  • GEC
  • ACEG

Pregunta 145

Pregunta
What is the typical air pressure when blowing fiber
Respuesta
  • 150-220psi
  • 150-200psi
  • 100-150psi
  • 200-225psi

Pregunta 146

Pregunta
Which splicing method has a low consumable cost
Respuesta
  • fusion
  • mechanical

Pregunta 147

Pregunta
What is the total opposition to current flow
Respuesta
  • Impedance
  • Capacitance
  • Resistance
  • Inductance

Pregunta 148

Pregunta
What is the basic unit of digital information
Respuesta
  • bit
  • megabit
  • bel

Pregunta 149

Pregunta
What type of entrance pathway preserves the aesthetic appearance of the building but is inflexible for future service changes
Respuesta
  • tunnel
  • underground
  • buried
  • aerial

Pregunta 150

Pregunta
What diameter of toggle bolts should be used when mounting a backboard
Respuesta
  • 1/4"
  • 3/8"
  • 1/2"
  • 5/8"

Pregunta 151

Pregunta
Open top cable supports should be installed to maintain a minimum of _____ inches above ceilings
Respuesta
  • 2
  • 3
  • 4
  • 5

Pregunta 152

Pregunta
Reflectance may be a concern with which type of splicing method
Respuesta
  • fusion
  • mechanical

Pregunta 153

Pregunta
This administration addresses the needs of premises served by a single ER (the only telecommunication space)
Respuesta
  • Class 1
  • Class 2
  • Class 3
  • Class 4

Pregunta 154

Pregunta
How much fiber typically should be in a splice tray
Respuesta
  • 3 feet
  • 1-2 meters
  • 1-3 meters
  • 1 meter

Pregunta 155

Pregunta
Identify this fusion
Respuesta
  • fuse time too long
  • autofeed too low
  • autofeed too high
  • fuse current too hot

Pregunta 156

Pregunta
Identify this fusion
Respuesta
  • fuse current too hot
  • autofeed too high
  • good splice
  • autofeed too low

Pregunta 157

Pregunta
Identify this fusion
Respuesta
  • autofeed too high
  • good splice
  • fuse time too long
  • fuse current too hot

Pregunta 158

Pregunta
Identify this fusion
Respuesta
  • autofeed too low
  • fuse time too long
  • autofeed too high
  • good splice

Pregunta 159

Pregunta
Identify this fusion
Respuesta
  • good splice
  • autofeed too high
  • autofeed too low
  • fuse time too long

Pregunta 160

Pregunta
What is the maximum splice loss regardless of the methodology
Respuesta
  • .3dB
  • .1dB
  • .75dB
  • 1.5dB

Pregunta 161

Pregunta
What is the curing cycle for heat cured connectors
Respuesta
  • 20 minutes
  • 10 minutes
  • 5 minutes
  • 15 minutes

Pregunta 162

Pregunta
24AWG stranded cable ha _______ more attenuation
Respuesta
  • 30%
  • 20%
  • 50%
  • 40%

Pregunta 163

Pregunta
Adhesive hardening when terminating anaerobic connectors takes how long
Respuesta
  • 10-20 seconds
  • 15 seconds
  • 1 minute
  • 5-10 seconds

Pregunta 164

Pregunta
True power is measured in ______
Respuesta
  • Watts
  • Volts
  • Amps
  • Decibels

Pregunta 165

Pregunta
What is the size of the primary acrylate
Respuesta
  • 125um
  • 250um
  • 245um
  • 5um

Pregunta 166

Pregunta
Measure of signal loss resulting from the insertion of component, link or channel between transmitter and receiver (often referred to as attenuation)
Respuesta
  • Crosstalk
  • Return loss
  • Delay skew
  • Insertion loss

Pregunta 167

Pregunta
How far should the toggle bolts be spaced when mounting a backboard
Respuesta
  • 1ft
  • 2ft
  • 18 inches
  • 3ft

Pregunta 168

Pregunta
All electrical activity produces electric & magnetic fields
Respuesta
  • True
  • False

Pregunta 169

Pregunta
What quantifies the bandwidth of a cabling system in a frequency range
Respuesta
  • megahertz
  • megabit
  • decibel

Pregunta 170

Pregunta
What is the #1 reason for troubleshooting in optical networks
Respuesta
  • contamination
  • core alignment
  • poor terminations

Pregunta 171

Pregunta
What device converts a digital signal into 2 distinctive analog frequencies
Respuesta
  • modem
  • codec

Pregunta 172

Pregunta
What is the power range for microscopes to view the end face of an optical fiber connector
Respuesta
  • 100x-800x
  • 100x-200x
  • 200x-400x

Pregunta 173

Pregunta
What is the ratio expressed in decibels of the power of the outgoing signal to the power of the reflected signal
Respuesta
  • Return loss
  • Insertion loss
  • Crosstalk
  • Delay skew

Pregunta 174

Pregunta
This is the grounding connection point for telecommunications systems and equipment in the area served by an ER or TR
Respuesta
  • GEC
  • TGB
  • TMGB
  • BCT

Pregunta 175

Pregunta
The inside bend radius shall be _______ times the ID for conduits 2 inches or less
Respuesta
  • 6
  • 10
  • 4
  • 8

Pregunta 176

Pregunta
This tool is used to inspect the radius of curvature, offset of polish & optical fiber height
Respuesta
  • VFL
  • Interferometer
  • OLTS
  • OTDR

Pregunta 177

Pregunta
This is the copper conductor that interconnects the TMGB to TGB
Respuesta
  • TBB
  • GEC
  • GE
  • ACEG

Pregunta 178

Pregunta
This is the unwanted transfer of a signal's EM energy from one or more circuits to other circuits
Respuesta
  • Crosstalk
  • Delay Skew
  • Return Loss
  • Insertion Loss

Pregunta 179

Pregunta
This tool can determine end-to-end attenuation & distance to a point of high attenuation during pre-installation testing
Respuesta
  • OTDR
  • OLTS
  • VFL
  • Interferometer

Pregunta 180

Pregunta
Test equipment uses what to determine the length of a cable
Respuesta
  • Crosstalk
  • NVP (nominal velocity of propagation)
  • Insertion Loss
  • Propagation Delay

Pregunta 181

Pregunta
How far does the conductor need to extend beyond the connector if using a set-screw, pass-through style lug
Respuesta
  • 1/8"
  • 1/4"
  • 1/2"
  • 3/8"

Pregunta 182

Pregunta
Cross-Connect Field Colors: Common Equipment
Respuesta
  • Purple
  • Green
  • Yellow
  • Red

Pregunta 183

Pregunta
What device converts analog data, from a video device, to a digital signal
Respuesta
  • modem
  • codec

Pregunta 184

Pregunta
The inside bend radius shall be ___ times the ID for conduits greater than 2 inches
Respuesta
  • 10
  • 6
  • 4
  • 8

Pregunta 185

Pregunta
Acceptance testing of optical fiber is most often performed with which tester
Respuesta
  • VFL
  • OLTS
  • OTDR
  • Interferometer

Pregunta 186

Pregunta
What are unsafe oxygen levels
Respuesta
  • below 19.5% and above 23.5%
  • below 20.5% and above 25.5%
  • below 15.5% and above 20.5%

Pregunta 187

Pregunta
Time for a signal to be transmitted from one end to the other
Respuesta
  • Crosstalk
  • Delay Skew
  • Propagation Delay
  • Insertion Loss

Pregunta 188

Pregunta
Which entrance pathway has the lowest cabling installation cost
Respuesta
  • Aerial
  • Underground
  • Buried
  • Wireless

Pregunta 189

Pregunta
For singlemode fiber, out-of-band testing may be accomplished at the _____ nm window
Respuesta
  • 1625
  • 1550
  • 1310
  • 1490

Pregunta 190

Pregunta
Difference in propagation delay between slowest & fastest pairs within same cable sheath
Respuesta
  • delay skew
  • crosstalk
  • insertion loss
  • return loss

Pregunta 191

Pregunta
What is the worst acceptable loss for a mated pair
Respuesta
  • .75dB
  • .5dB
  • .3dB
  • 1.0dB

Pregunta 192

Pregunta
95% of mated pairs shall be better than ____dB loss
Respuesta
  • .75dB
  • .5dB
  • .3dB

Pregunta 193

Pregunta
This type of protector has a reaction time of 10-15 ns
Respuesta
  • Gas
  • Carbon
  • Solid state
  • Fire & data

Pregunta 194

Pregunta
There is currently no maximum bandwidth for singlemode optical fiber
Respuesta
  • True
  • False

Pregunta 195

Pregunta
This firestop material expands when exposed to fire or heat
Respuesta
  • intumescent
  • ablative
  • endothermic

Pregunta 196

Pregunta
This backbone cable distributes telecommunications services between buildings
Respuesta
  • interbuilding
  • intrabuilding

Pregunta 197

Pregunta
Cross-Connect Field Colors: Demarcation Point
Respuesta
  • Orange
  • Brown
  • White
  • Red

Pregunta 198

Pregunta
What is the maximum amount of exposure between the insulation and the bonding connector
Respuesta
  • 1/8"
  • 1/2"
  • 1/4"
  • 3/8"

Pregunta 199

Pregunta
What can be used to neutralize small acid spills
Respuesta
  • sodium bicarbonate
  • water
  • milk
Mostrar resumen completo Ocultar resumen completo

Similar

Chapter 5 Copper
eric rinehart
Telecomms Rigging
peter.roberts
EXAMEN DE MATEMATICAS PRIMER GRADO SECUNDARIA
FELIPE SOLTERO
Esquema del reformismo ilustrado en España
maya velasquez
Inglés para Selectividad
Diego Santos
Elementos de la música
martha.celorio
La Edad Media en la Música
martha.celorio
Promoción de ventas
VICTOR HUGO ORTIZ ALCALA
Preguntas abiertas La Segunda República
Salustiano Gutiérrez Baena