In a turbine circuit, feed heaters and dearators serve to:
Respuesta
use up excess steam
Increase efficiency
Provide load during low demand periods
Increase turbine output
Pregunta 2
Pregunta
The high-pressure oil system of a typical turbine supplies oil to
Respuesta
Bearings
Gears
Emergency stop valves
The oil purifier
The auxillary oil pump
Pregunta 3
Pregunta
When starting a condensing or extraction turbine, the extraction (condensate)pump is started ______ the _____
1. before
2. after
3. air ejector
4. jacking oil pump
5. condenser circulating water pump
Respuesta
1,3
2,3
1,4
1,5
2,5
Pregunta 4
Pregunta
When starting an extraction turbine, sealing steam to the turbine glands is admitted _____ is put in operation
Respuesta
Before the extraction pump
Before the condenser circulating water pump
After the air ejector
After the extraction pump
After the throttle valve is open
Pregunta 5
Pregunta
The jacking oil pump is shut down when the turbine reaches a speed of approximately _____ rpm
Respuesta
5-10
20-30
40-50
50-60
0-80
Pregunta 6
Pregunta
The overspeed trip a turbine is usually set to trip the mechanism when it reaches ____ of operating speed
Respuesta
100%
105%
110%
115%
120%
Pregunta 7
Pregunta
Lubricating oil for a turbine may:
1. Lubricate bearings
2. Lubricate gears.
3. Operate throttle valves.
4. Be supplied to a governor.
Respuesta
1,2
3,4
1,2,3
2,3,4
1,2,3,4
Pregunta 8
Pregunta
When a hydraulic overspeed trip operates
1. High pressure oil forces the main steam valve shut.
2. High pressure oil supply is shut off
3. The stop valve oil cylinder drain is closed.
4. The stop valve oil cylinder drain is opened
5. A spring closes the main steam valve
6. The pilot drain is closed
Respuesta
1,3,6
2,4,5
3,4,6
2,4,6
3,4,5
Pregunta 9
Pregunta
The warm up time required of a turbine is dependant on