Chapter 5 - Piping, Fittings, and Valves

Descripción

Quiz #5
Neil Revollo
Test por Neil Revollo, actualizado hace más de 1 año
Neil Revollo
Creado por Neil Revollo hace alrededor de 8 años
1333
1

Resumen del Recurso

Pregunta 1

Pregunta
Hydronic heating systems should never use a combination of flexible and rigid piping materials.
Respuesta
  • True
  • False

Pregunta 2

Pregunta
In the absence of any building or mechanical codes that require otherwise, type M is the standard for copper tubing used in hydronic heating systems.
Respuesta
  • True
  • False

Pregunta 3

Pregunta
Plumbing codes no longer allow solders containing lead to be used for domestic water service.
Respuesta
  • True
  • False

Pregunta 4

Pregunta
The molecular structure of nonmetallic tubes such as those made of PEX or rubber compounds is such that oxygen molecules can diffuse through their tube walls and be absorbed by the fluid within.
Respuesta
  • True
  • False

Pregunta 5

Pregunta
The pressure difference between the inside and outside of the tube has a very strong effect on oxygen diffusion.
Respuesta
  • True
  • False

Pregunta 6

Pregunta
A well-planned piping assembly will use the largest number of fittings possible.
Respuesta
  • True
  • False

Pregunta 7

Pregunta
Due to thermal expansion, the greater the length of the pipe, and the greater the temperature change, the greater the change in length.
Respuesta
  • True
  • False

Pregunta 8

Pregunta
A feed water valve is used to increase the pressure of water from a domestic water distribution pipe before it enters a hydronic system.
Respuesta
  • True
  • False

Pregunta 9

Pregunta
Piping schematics are the road maps of hydronic system design. Unfortunately, there is no universal standard for piping symbols to which all those in the hydronics industry subscribes.
Respuesta
  • True
  • False

Pregunta 10

Pregunta
In situations where both piping and electrical wiring are in close proximity, try to keep the piping above the electrical wiring.
Respuesta
  • True
  • False

Pregunta 11

Pregunta
In situations where good heat transfer through the walls of the pipe is desirable, __________ is unsurpassed.
Respuesta
  • stainless steel
  • copper
  • cross-linked polyethylene
  • composite tubing

Pregunta 12

Pregunta
Copper water tube is available in three wall thicknesses designated as types __________ in order of decreasing wall thickness.
Respuesta
  • A, B, and C
  • S, M, and L
  • K, L, and M
  • 1, 2, and 3

Pregunta 13

Pregunta
Copper tubing must be properly supported to prevent sagging or buckling. On horizontal runs of hard temper tubing, the maximum support spacing for 1/2- and 3/4-inch tube is __________ feet.
Respuesta
  • 2
  • 3
  • 4
  • 5

Pregunta 14

Pregunta
In situations where several runs of piping and/or electrical conduit must be run in close proximity, a __________ system is a good option.
Respuesta
  • mounting rail
  • rubber liner
  • horizontal piping
  • vertical piping

Pregunta 15

Pregunta
Fittings for copper tubing are available in either wrought copper or __________.
Respuesta
  • stainless steel
  • PEX
  • tempered rubber
  • cast brass

Pregunta 16

Pregunta
When long straight runs of rigid tubing are required, it may be necessary to install an expansion loop or an expansion offset to absorb the movement. Another alternative is to install an expansion __________ capable of absorbing the movement.
Respuesta
  • regulator
  • compensator
  • barometer
  • overflow

Pregunta 17

Pregunta
Feed water valves operate by balancing the force generated by water pressure against an internal flexible __________, with the counterforce generated by a partially compressed spring.
Respuesta
  • feeder
  • cavitator
  • diaphragm
  • pressurizer

Pregunta 18

Pregunta
Hydronic heating systems, once assembled, must be filled, purged of air, and filled with fluid. A(n) __________ is specifically designed for this purpose.
Respuesta
  • purging valve
  • air deactivator valve
  • ball valve assembly
  • flow regulator valve

Pregunta 19

Pregunta
If the inlet pressure on the backflow preventer drops below the pressure in the hydronic system, springs return both check valves and the movable cartridge to their __________ positions.
Respuesta
  • open
  • closed
  • original
  • preset

Pregunta 20

Pregunta
Another specialty valve widely used in hydronic systems provides the ability to isolate, flow balance, and even drain individual heat emitters. It is called a __________.
Respuesta
  • zone valve
  • balancing valve
  • differential pressure bypass valve
  • lockshield valve
Mostrar resumen completo Ocultar resumen completo

Similar

Chapter 1 - Modern Hydronic Heating
Neil Revollo
Chapter 6 - Fluid Flow in Piping
Neil Revollo
types of bullying
Gabriela Morales
Questions 1-15
Faith Gavino
Mack Images North Africa
Emily Williams
Enter text here
JIE CHEN
Questions 16-30
Faith Gavino
Questions 46-60
Faith Gavino
Questions 31-45
Faith Gavino
Questions 61-77
Faith Gavino
Microeconomics/Econ202 Practice Test 1
Lauren Beets