Chapter 9 - Quiz

Descripción

Control Strategies, Components, and Systems
Neil Revollo
Test por Neil Revollo, actualizado hace más de 1 año
Neil Revollo
Creado por Neil Revollo hace alrededor de 8 años
364
0

Resumen del Recurso

Pregunta 1

Pregunta
For current-generation hydronic heating systems, the controlled variable is usually indoor air temperature.
Respuesta
  • True
  • False

Pregunta 2

Pregunta
Most of the closed-loop control systems used for hydronic heating continually seek to eliminate any error that exists between the target value and measured value of the controlled variable.
Respuesta
  • True
  • False

Pregunta 3

Pregunta
Heat output from the heat emitter occurs whenever the supply water temperature equals the room air temperature.
Respuesta
  • True
  • False

Pregunta 4

Pregunta
The combination of near-continuous circulation and very gradual changes in water temperature tends to maximize expansion noises from the distribution piping and heat emitters.
Respuesta
  • True
  • False

Pregunta 5

Pregunta
Most heat source reset controllers have an adjustable minimum supply temperature.
Respuesta
  • True
  • False

Pregunta 6

Pregunta
Relay contacts are designated as normally open, or normally closed. In this context, the word "normally" means when the coil of the relay is not energized.
Respuesta
  • True
  • False

Pregunta 7

Pregunta
There are hydronic heating applications where control action is required based on the difference between two temperatures rather than the value of either temperature.
Respuesta
  • True
  • False

Pregunta 8

Pregunta
A multizone relay center is designed to isolate the wiring and control operation of several independent zone circulators or zone valves.
Respuesta
  • True
  • False

Pregunta 9

Pregunta
One purpose of mixing is to protect conventional boilers from operating at conditions that allow sustained flue gas condensation.
Respuesta
  • True
  • False

Pregunta 10

Pregunta
Direct injection mixing, whether accomplished using a two-way valve or variable-speed pump as the injection control device, provides the highest temperature difference between the supply and return injection risers.
Respuesta
  • True
  • False

Pregunta 11

Pregunta
The proper documentation of control systems is essential if they are to be expediently serviced in the future. A universally accepted tool for such documentation is the __________.
Respuesta
  • microprocessor
  • ladder diagram
  • designer spreadsheet
  • flow chart

Pregunta 12

Pregunta
The term __________ differential refers to the actual variation in the controlled variable as the system operates.
Respuesta
  • control
  • modulating
  • operating
  • real-time

Pregunta 13

Pregunta
To provide accurate control under low-load conditions, the controlled device must be able to maintain stable flow at very low flow rates. Such a device is said to have good __________.
Respuesta
  • modulation
  • variability
  • machining
  • rangeability

Pregunta 14

Pregunta
As outdoor temperature increases, and the heating load decreases, the water temperature supplied to the heat emitters also decreases as does their heat output. This concept is called outdoor __________ control.
Respuesta
  • temperature
  • variable
  • proportional
  • reset

Pregunta 15

Pregunta
Switches and relays are classified according to their poles and throws. The number of __________ is the number of independent and simultaneous electrical paths through the switch.
Respuesta
  • poles
  • throws
  • contacts
  • wires

Pregunta 16

Pregunta
__________ control is a planned strategy for shedding (e.g., temporarily turning off) one or more loads when a specific condition is detected in the system.
Respuesta
  • Error
  • Priority
  • Systemic
  • Conditional

Pregunta 17

Pregunta
In addition to equal run time rotation, there are other operating options available for staged/modulating heat sources. They are called series staging/modulation, parallel staging/modulation, and __________ staging/modulation.
Respuesta
  • proportional
  • on/off
  • multiple
  • hybrid

Pregunta 18

Pregunta
Boiler protection is accomplished by __________ the rate of heat flow from the boiler into the distribution system whenever the boiler temperature approaches or falls below a specified minimum operating temperature.
Respuesta
  • reducing
  • resetting
  • increasing
  • stabilizing

Pregunta 19

Pregunta
The term injection mixing applies to any mixing assembly in which __________ is pushed (e.g., injected) into a circulating distribution system.
Respuesta
  • coolant
  • air
  • hot water
  • mercury

Pregunta 20

Pregunta
A network control system without Internet access requires a person to be present to interrogate or adjust the system. This is unnecessary with a(n) __________ networked control system.
Respuesta
  • Web-enabled
  • electronic
  • electromechanical
  • fuzzy logic
Mostrar resumen completo Ocultar resumen completo

Similar

Coronary 1 Practice
romalsp
Quotes from William Shakespeare's Romeo and Juliet
cecicurtis
Exam Part 1 of Nursing 112 FInal GBCC
Tess Nicholson
Life Science 7 Final Exam
pcsalazar
Motivational Interviewing
Julie HEYRMAN-COMPERNOLLE
AP Environmental Science
sabrinapar22
Obligations and Contracts - Provisions
mitchdeocampo
types of bullying
Gabriela Morales
Chapter 11 - Quiz
Neil Revollo
PBSC BSC1011L Final Exam Study Guide
Emily W
CGC 1D/P Geography Mind Map