7 Firestopping

Descripción

(Class Quiz) Class quiz Test sobre 7 Firestopping, creado por Jeanie Fitzgerald el 25/07/2017.
Jeanie Fitzgerald
Test por Jeanie Fitzgerald, actualizado hace más de 1 año
Jeanie Fitzgerald
Creado por Jeanie Fitzgerald hace casi 7 años
132
1

Resumen del Recurso

Pregunta 1

Pregunta
For all job specific firestopping issues, the information and communications technology ( ICT ) systems cabling installer should consult who
Respuesta
  • Fire marshall
  • OSHA
  • AHJ
  • Client

Pregunta 2

Pregunta
The most common fire protection principle is
Respuesta
  • containment
  • compartmentation
  • extinguishing

Pregunta 3

Pregunta
Fire safety must provide: check all that apply
Respuesta
  • containment
  • detection
  • suppression
  • ventilation

Pregunta 4

Pregunta
A fire assembly is based on: Check all that apply
Respuesta
  • fire barrier
  • construction
  • penetration
  • firestop material

Pregunta 5

Pregunta
Who can be held legally, criminally and financially responsible if the manufacturer's instructions are not followed.
Respuesta
  • the installer
  • the contracted company
  • the supplier

Pregunta 6

Pregunta
When firestopping the installer may substitute or add more product to get a higher rating.
Respuesta
  • True
  • False

Pregunta 7

Pregunta
Time period (expressed in hours) that assembly resists flame passage
Respuesta
  • F rating
  • T rating
  • L rating

Pregunta 8

Pregunta
Time period that a the unexposed surface of the assembly or any penetrating item does not exceed (325 degrees) above its initial temperature
Respuesta
  • F rating
  • T rating
  • L rating

Pregunta 9

Pregunta
This simulates smoke leakage through a firestop assembly.
Respuesta
  • F rating
  • T rating
  • L rating

Pregunta 10

Pregunta
Mechanical firestop systems use _______________ firestop materials which are flexible and resemble rubber.
Respuesta
  • Intumescent
  • Elastomeric
  • Endothermic

Pregunta 11

Pregunta
Non-mechanical firestop materials have three basic properties. Select the one that has the ability to absorb heat which prevents the temperature from rising on the other side of the fire barrier.
Respuesta
  • Intumescent
  • Endothermic
  • Ablative

Pregunta 12

Pregunta
This non-mechanical firestop has the ability to expand when exposed to fire or heat. The material swells around and within the penetration to provide a tight seal.
Respuesta
  • Intumescent
  • Endothermic
  • Ablative

Pregunta 13

Pregunta
This non-mechanical firestop develops a hard char that resists erosion from fire or flames.
Respuesta
  • Intumescent
  • Endothermic
  • Ablative

Pregunta 14

Pregunta
Intumescent _________________ are used for plastic piping, insulated metal piping, cable bundles, plastic conduit or materials that may burn away in a fire.
Respuesta
  • Sheets
  • Pads
  • Wrap strips

Pregunta 15

Pregunta
____________________ are common with a long shelf life, ease of installation and wide range of applications. Most are endothermic but may be intumescent. Comes in bulk, bars or sticks.
Respuesta
  • Caulk
  • Firestop putty
  • wrap strips

Pregunta 16

Pregunta
This material may be endothermic, ablative or intumescent and are for permanent installations not intended to be re-entered.
Respuesta
  • Firestop putty
  • Caulk
  • Foams

Pregunta 17

Pregunta
This is sometimes referred to as a pipe choke system.
Respuesta
  • Sleeve systems
  • Collars
  • Wrap strips

Pregunta 18

Pregunta
__________ are dispensed from a two part mixing tube and quickly cures to form a tight seal. May be intumescent, endothermic or ablative.
Respuesta
  • Caulk
  • Putty
  • Foam

Pregunta 19

Pregunta
In situations where critical power or data cables must remain in operation and primarily for large air handling and exhaust vents this is used.
Respuesta
  • Sheets
  • Firestop blankets
  • Pillows

Pregunta 20

Pregunta
All components used to make up a listed assembly are designed and tested as a unit and the parts are not interchangeable.
Respuesta
  • True
  • False

Pregunta 21

Pregunta
Which methods can limit the potential for problems and provide a better long term solution to firestopping Check all that apply
Respuesta
  • Retrofit split sleeves or sleeve systems
  • core bore seals
  • pathway barrier penetration plates ( PBPPs)
Mostrar resumen completo Ocultar resumen completo

Similar

PROCESADORES DE TEXTO
rm-asociados
Arte Barroco
juanmadj
Examen Primer trimestre
jorgeluisparedes
Past Simple of Irregular Verbs
Ana María Lara díez
RENACIMIENTO
abisai19971
Elaboración de mapas mentales_1
lariza2893
AMBIENTES VIRTUALES DE APRENDIZAJE (AVA)
naansara1993
HOW TO WAKE UP EARLY
Elaine del Valle
EL CAMINO DE STEVE JOBS
Evelyn Salazar
Paso 2 - Planificación
lucenith rosado
ISLAM
Joan Sempere