Arterial Line (A Line) -Avoid applying a BP cuff above the infusion site -Grasp the IV line support pole so the infusion site is at least at heart level -Avoid activities that require the infusion site to be above the level of the heart for a prolonged time -Exercise is possible with the line, but avoid disturbing the apparatus -PRIMARY PURPOSE: measure BP -Purpose: measure oxygen staturation
Swan-Ganz Catheters (Pulmonary Artery Catheters) -Exercise is possible with the line, but mobility may need to be restricted near the catheter insertion -PURPOSE: Measures R atrial pressure, pulmonary pressure -Inserted through femoral, brachial, or jugular vein into pulmonary artey
Total Parenteral Nutrition, Hyperalimentatoin Devices (Intravenous Feeding) -Alarm sound indicates the fluid source is empty or the system has become unbalanced -Disruption or disconnection may result in an air embolus -Shoulder motion on the side of the infusion site may be restricted primarily flexion and abduction -Exercise is possible with the line, but mobility may need to be restricted near the catheter insertion
Intracranial Monitoring -Isometric exercises an the valsalva maneuver should be avoided since these activities increase intracranial pressure -Avoid neck flexion, hip flexion > 90*, and prone position -Venous drainage is maximal with the head of bed elevated 30* -Momentary elevation of intracranial pressure is normal, but sustained increases are not and therefore should be reported
Nasogastric Tubing (NG Tube) -Pt. will not be able to eat food or drink fluids by mouth while the tube is in place -Enteral feedings can be disconnected temporarily for mobility -Exercise requiring movements of the head and neck should be avoided, especially flexion
Gastrostomy Tubing (G Tube) -Distal tubing can inadvertently become caught on items such as furniture and be pulled out -Enteral feedings should be turned off prior to and during treatment -Enteral feedings can be disconnected temporarily for mobility
Urinary Catheters -Tubes should be placed below the region being drained since device relies on gravity -The collection bag should not be raised above the level of the bladder for a sustained period -Avoid disturbing, stretching, disconnecting or occluding the tube during exercise
Chest Tubes -When ambulating, collection bottles should be kept below the level of the inserted tube location -Monitor the pt. for changes in breath sounds before and after intervention -Avoid pressing directly on the chest tube during mobility activities
Mechanical Ventilation -Alarm may indicate disconnected tube, coughing or change in respiratory pattern -Develop nonverbal means of communication with the pt -Pt. is at greater risk for developing contractions, skin ulcers, and deconditioning
Supplemental Oxygen Delivery System -Be aware of signs of respiratory distress (dyspnea, cramping, cyanosis) -Monitor SaO2, PaO2 and hemodynamic prior to, during, and after intervention -Exercise is possible, but avid disturbing the tubing
Central Venous Pressure Catheter -Measures pressure in the right atrium or the superior vena cava -Use to evaluate the right ventricle function, right atrial filling pressure, and circulation of blood volume -this significantly reduces the need for repeated venipuncture
Oximeter -Used to determine the oxygen saturation of blood -Commonly applied to finger or ear -Assess activity tolerance
Jejunostomy tube (J tube) -Tube inserted through endoscopy into the jejunum via abdominal wall -Used for long term feeding
Nasal Cannula -Tubing extending approximately 1cm into each nostrils -Capable of delivering up to 6L of oxygen
Oronasal Mask -Consists of facepiece covering nose and mouth -Used most often with oxygen therapy -Can be used to administer medicine, mucolytic detergents, or humidity by nebulizer
Tent -A canopy placed over the head and shoulders or entire body -Purpose to deliver oxygen at a higher level than normal
Tracheostomy Mask - Mask placed over a stoma or tracheostomy -Purpose to administer supplemental oxygen
Balance Suspension Traction -Surgically placed pins, screws and wires into a bone -Purpose to apply a traction force using an externally applied weight -Often used for femur fx -Requires prolonged immobilization
External Fixation -Surgical procedure where fx is set in to anatomically desirable position -An external frame is used to maintain the bony fragments -Enhances stability and allows early mobilization
Internal Fixation -Surgical procedure that attempts to promote the healing process of the bone without external frame -Commonly used with comminuted or displaced fx -Provides needed stability to heal joints and allows early mobilizations -less post-op complications
Foley Catheter -Indwelling urinary tract catheter that has balloon attached at the indwelling end -Balloon filled with air or sterile water must be deflated before catheter can be removed
Suprapubic Catheter -An indwelling urinary tract catheter -Surgically inserted directly into the patient's bladder -Performed under general anesthesia
Ostomy Device -Provides a method for collection of waste from a surgically produced opening in the abdomen -Removal of waste occurs through the stoma extending into the small stomach -Waste is collected into a plastic bag or pouch -Typically air and water tight -Allow the user to lead active normal lifestyle
Mostrar resumen completo Ocultar resumen completo

Similar

World Syllabus
mariah.felty
typeahead chapter/section
tosbourn
Other Separation Techniques Outcomes
Sean Sacriz
Business Studies - AQA - GCSE - Location Factors
Josh Anderson
Food Flashcards
Megan Tchir
Qué Carrera Estudiar
maya velasquez
Fórmulas Geométricas (Áreas)
Diego Santos
Reclutamiento del Personal
santiago06_
ENGLISH CLASS FUTURE FORMS
pablomac8
LA METODOLOGÍA DE LAS BASES DE DATOS
Fernando Tapia