R VALUE?
OBC R VALUE FOR CEILING?
OBC R VALUE WALLS?
K VALUE?
ESA STAND FOR?
WHAT DOES PLANNING DEPART. DO IN OBC?
Fire Separation
ZONING
Fire Wall
Flame Spread Rating
BUILDING CODE
Smoke Development Classification
BUILDING PERMIT REQUIREMENT?
CLASSIFICATION HELPS DESIGNER?
WHEN SPRINKLERS REQUIRED?
THINGS TO TAKE INTO ACCOUNT FOR OCCUPANCY?
EXISTS REQUIRED FOR A BUILDING?
OCCUPANCY LOAD DETERMINATION?
HOW DO SPRINKLERS WORK?
AREA PER PERSON IN AN OFFICE?
SIZE OF STANDPIPES?
AREA PER PERSON IN READING/ WRITING LOUNGES?
LOCATION AND ROLE OF STANDPIPES?
AREA PER PERSON IN LABS?
Where are fire host cabinets?
AREA PER PERSON IN MANUFAC?
WHAT DRY SYSTEMS?
AREA PER PERSON IN AN CLEANING/ REPAIR?
WHAT WET SYSTEM?
AREA PER PERSON IN AN STORAGE?
VARIETY OF SPRINKLERS?
AREA PER PERSON IN PUBLIC CORRIDORS?
WHAT SPRINKLER TO USE FOR COMMERCIAL/ INDUSTRIAL DESIGN?
WHICH SPRINKLER CAN NOT BE PAINTED?
BUILDING FIRE SAFETY COVERS?
AREA COVERAGE ABOVE FF + WATER PRESSURE IS DETERMINED BY?
EXISTS COVER?
AREA COVERAGE FOR SPRINKLERS IN WAREHOUSES?
HEALTH REQUIREMENTS COVER?
AREA COVERAGE FOR SPRINKLERS IN MANUFAC?
FIRE REISISTANCE RATING?
Fire Protection Rating
AREA COVERAGE FOR SPRINKLERS IN OFFICE?
AREA COVERAGE FOR SPRINKLERS IN RESIDENTIAL/HOTEL?
IN DRY SYSTEMS, where can water freeze the pipe?
List chemical systems where where water would pose a significant
safety risk or huge financial loss
Name dry system gases?
In dry gas systems, what requires
Chemical fire suppression?
Conditions for storage of dry system gases?
When are audible alarms and visual strobes needed.
How do you fire rate a glass partition?
How much area does a class sprinkler cover?
List types of connections for glass sprinklers?
What are Fire Alarm Systems connected to?
Every floor area must have 2 exits with the exceptions of?
Egress doors in a hotel shall not be fewer than?
Difference between EXIT and EGRESS?
(individual components vs. path)
Required distance between exists?
What is travel distance?
Travel distance in suits?
With some exceptions the maximum travel distance in in business and personal services is?
With some exceptions the maximum travel distance in other buildings?
Travel distance is measured at how many cm off the wall?
Travel distance is identical to?
A corridor for which there is an exit in only one direction occurs in which groups?
In Business and Personal Services a dead end corridor shall have how many doors before reaching the nearest exist.
Exit Width
range per person depending
on Occupancy and type is?
For ramps with a slope of not more than 1 in 8, doorways, corridors and passageways should have how much area/person?
For stair consisting of steps whose rise is not more than 180 mm and whose run is not less than 280 mm should have how much area/person?
9.2 mm per person is for?
If a stair discharges in the middle of
a building, what is required?
Doors need to open into the path of travel.
Exit typically opens to the outside.
TRUE OR FALSE
Fire Zones / Areas would need to
be protected with fire shutters that are linked to the fire alarm and would
automatically close in case of an alarm.
TRUE OR FALSE