Filip Carpentier
Test por , creado hace más de 1 año

Examination after the training

145
0
0
Filip Carpentier
Creado por Filip Carpentier hace alrededor de 9 años
Cerrar

Training exam

Pregunta 1 de 9

1

What are the requirements for the DICOM Purge feature in order to work?

Selecciona una o más de las siguientes respuestas posibles:

  • Images need to be cleared form the local PIC folder.

  • Images need to be archived to a PACS

  • Images need to be cleared form the local PIC folder OR Images need to be archived to a PACS

  • Images need to be cleared form the local PIC folder AND Images need to be archived to a PACS

Explicación

Pregunta 2 de 9

1

What is required to enable the QC in Eye Care PACS

Selecciona una o más de las siguientes respuestas posibles:

  • 1. HL7 orders must be supported and activated.
    2. User need to belong to SymphonyWebAutors Group

  • 1. HL7 must be supported and activated.
    2. User need to belong to SymphonyWebQCUsers Group

  • 1. HL7 orders must be supported and activated.
    2. User need to belong to SymphonyWebQCUsers Group

Explicación

Pregunta 3 de 9

1

What is needed to configure the OISDFC.INI for DICOM archive of the DCZ container files

Selecciona una de las siguientes respuestas posibles:

  • SOP Class and Transfer Syntax

  • SOP Class and Study UID

  • Instance UID & Transfer Syntax

  • Instance UID & Study UID

Explicación

Pregunta 4 de 9

1

What type of HL7 messages do we support?

Selecciona una de las siguientes respuestas posibles:

  • ADT, ORU, MDM, QRY, ORM, QBP, ACK

  • ORM, ORU, ADT, QRY, MFN, ACK

  • BAR, ADT, ORU, MFN, ACK, QRY, QBP

Explicación

Pregunta 5 de 9

1

Message Trigger Events for HL7.
What are the activities that should cause the Information System (IS) to initiate a message:

Selecciona una o más de las siguientes respuestas posibles:

  • The IS interface sends an order message (ORM) to EyeStation, when an order is created,
    updated, or cancelled. This message usually contains patient and physician information along with
    requested observation details.

  • The IS interface sends an ADT message to EyeStation, whenever a patient's demographics are
    updated, or a patient is merged, or to send a response to demographics query.

  • The IS interface sends an MFN message to EyeStation, whenever a physician information is
    added/updated.

Explicación

Pregunta 6 de 9

1

Message Trigger Events
The following activities cause the EyeStation to initiate a message:

The EyeStation sends an order result message (ORU) to IS, whenever an order is fulfilled.
● The EyeStation sends an MDM or ORU message to IS, when a digital report is created or updated.
● The EyeStation sends a query message (QRY) to IS, whenever patient validation and additional
demographic data is required.
● The EyeStation sends an ACK message (positive or negative acknowledgement) to IS, when an
ORM, ADT, or MFN message is received and processed.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 7 de 9

1

HL7 Message Rule file. What is the meaning of the different types of brackets?

Selecciona una de las siguientes respuestas posibles:

  • { } Curly braces indicate that a segment can repeat
    [ ] Square brackets indicate that a segment is optional

  • { } Curly braces indicate that a segment is optional
    [ ] Square brackets indicate that a segment can repeat

Explicación

Pregunta 8 de 9

1

With SegDef file we define what segments we expect
- How many
- What order
- Which messages do we use to add/update or merge.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 9 de 9

1

What are the HASP bits needed for a MECP server with 8 users, import form IOLMaster, Spectralis, Nidek Micro-Perimeter, Oculus Pentacam, RetCam

Selecciona una o más de las siguientes respuestas posibles:

  • Winstation Version Number 11, SymphonyWeb enabled, Symphony Web Number of Licenses: 8, Montage enabled, Auto History, Auto Stabilizer, Perfect View , Net HASP, OCT, VFA, ULT, MO1, CTP

  • Winstation Version Number 11, SymphonyWeb enabled, Symphony Web Number of Licenses: 8, Review, Montage enabled, Auto History, Auto Stabilizer, Perfect View, Net HASP OCT, VFA, ULT, MO1, CTP

  • Winstation Version Number 11, SymphonyWeb enabled, Symphony Web Number of Licenses: 8, Montage enabled, Auto History, Auto Stabilizer, Perfect View OCT, VFA, ULT, MO1, CTP

Explicación