Neil Revollo
Test por , creado hace más de 1 año

Distribution Piping Systems

455
1
0
Neil Revollo
Creado por Neil Revollo hace alrededor de 8 años
Cerrar

Chapter 11 - Quiz

Pregunta 1 de 20

1

A zone is any area of a building for which indoor air temperature is controlled by a single thermostat (or other type of temperature controller).

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 2 de 20

1

Different rooms within a single zone (e.g., controlled by a single thermostat) and supplied with the same water temperature cannot be maintained at different temperatures by adjusting the flow rate through individual heat emitters.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 3 de 20

1

If the heat emitters are connected in series , the system flow rate will pass through each heat emitter. If the heat emitters are connected in parallel, the flow rate through each heat emitter can be proportioned based on load using an equation.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 4 de 20

1

Given the surface area of their bodies, hydraulic separators should be insulated to minimize heat loss to their surroundings.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 5 de 20

1

Designers should think of hydraulic separation as a physical concept that must be accomplished as an all-or-nothing condition.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 6 de 20

1

When a circulator with the flat curve is used, the differential pressure across the circulator changes dramatically as zone circuits turn on and off.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 7 de 20

1

The electronically commutated motors and improved hydrodynamic design of current generation variable-speed pressure-regulated circulators provide wire-to-water efficiencies that are approximately double those of standard wet-rotor circulators with permanent split capacity.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 8 de 20

1

If a fixed-speed circulator is selected, a differential pressure bypass valve should be installed to reduce the potential for flow noise when only one or two zones are active.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 9 de 20

1

Over the last two decades, many heating professionals have come to recognize the failure of PEX and PEX-AL-PEX tubing as universal piping materials for residential and light commercial hydronic systems.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 10 de 20

1

Primary/secondary (P/S) piping is the only way to achieve hydraulic separation between simultaneously operating circulators.

Selecciona uno de los siguientes:

  • VERDADERO
  • FALSO

Explicación

Pregunta 11 de 20

1

The time required to cool down or warm up a zone is significantly affected by the __________ of the heat emitter(s), and the building itself.

Selecciona una de las siguientes respuestas posibles:

  • thermal envelope

  • thermal mass

  • ambient temperature

  • setpoint temperature

Explicación

Pregunta 12 de 20

1

All hydronic systems, regardless of how they are designed or installed, attempt to simultaneously stabilize at two unique operating conditions called thermal equilibrium and __________ equilibrium.

Selecciona una de las siguientes respuestas posibles:

  • spatial

  • hydraulic

  • zoning

  • R-value

Explicación

Pregunta 13 de 20

1

In a technique known as __________, the designer repeatedly analyzes both the hydraulic and thermal performance of a system using "candidate" hardware options and operating conditions, until a combination is found that yields acceptable heat distribution.

Selecciona una de las siguientes respuestas posibles:

  • trial and error

  • selective pairing

  • elimination

  • iteration

Explicación

Pregunta 14 de 20

1

Ideally, each circulator in a system will establish a differential pressure and flow rates that is unaffected by the presence of another operating circulator within the system. This very desirable condition is called __________.

Selecciona una de las siguientes respuestas posibles:

  • hydraulic equilibrium

  • hydraulic separation

  • the pump curve

  • ideal circulation

Explicación

Pregunta 15 de 20

1

The degree to which two operating circulators interact with each other depends on the head loss of the piping path they have in common. This piping path is called the __________ piping.

Selecciona una de las siguientes respuestas posibles:

  • circulatory

  • serpentine

  • head loss

  • common

Explicación

Pregunta 16 de 20

1

The purpose of differential pressure bypass valves (DPBV) is to _________ the differential pressure imposed on the distribution system by a fixed-speed circulator as the system flow rate decreases due to closing zone valves.

Selecciona una de las siguientes respuestas posibles:

  • accelerate

  • equalize

  • limit

  • increase

Explicación

Pregunta 17 de 20

1

One approach that takes advantage of the flexibility of PEX or PEX-AL-PEX tubing is called a __________ distribution system.

Selecciona una de las siguientes respuestas posibles:

  • hydroplastic

  • home run

  • hybrid

  • green

Explicación

Pregunta 18 de 20

1

The closely spaced tees connecting a secondary circuit to the primary circuit are __________ when air is being purged from the system.

Selecciona una de las siguientes respuestas posibles:

  • counterproductive

  • instrumental

  • essential

  • irrelevant

Explicación

Pregunta 19 de 20

1

The concept of __________ provides a means by which the electrical energy consumption of a distribution system, per unit of heat delivery capacity, can be calculated and compared.

Selecciona una de las siguientes respuestas posibles:

  • hydraulic separation

  • hydraulic equilibrium

  • thermal envelope

  • distribution efficiency

Explicación

Pregunta 20 de 20

1

The diverse loads served by many modern residential and light commercial systems often dictate that the distribution system contains elements from __________ of the basic distribution systems discussed in this chapter.

Selecciona una de las siguientes respuestas posibles:

  • one specific

  • two or more

  • at least three

  • possibly none

Explicación