Rigoberto Franco
Quiz por , criado more than 1 year ago

Practica para certificarte

153
2
0
Rigoberto Franco
Criado por Rigoberto Franco mais de 10 anos atrás
Fechar

Test 2

Questão 1 de 115

1

What type of VNX MPFS configuration is illustrated with this topology?

Selecione uma das seguintes:

  • VNX gateway with FC

  • VNX with iSCSI/FC

  • VNX with iSCSI/FCoE

  • VNX gateway with MPFSi

Explicação

Questão 2 de 115

1

The majority of your customer's servers have highly utilized database applications that
require predictable performance. What type of storage do you recommend?

Selecione uma das seguintes:

  • RAID Groups with traditional LUNs

  • Storage groups with thick LUNs

  • Pool with traditional LUNs

  • RAID Groups with thin LUNs

Explicação

Questão 3 de 115

1

What type of VNX configuration is illustrated with this topology?

Selecione uma das seguintes:

  • VNX MPFS with iSCSI/FC

  • VNX MPFS with FC/FCoE

  • VNX gateway with iSCSI/FC

  • VNX gateway with FC

Explicação

Questão 4 de 115

1

While gathering performance data during peak workloads, which type of collection
method is best suited?

Selecione uma das seguintes:

  • Larger periods of data collection over shorter intervals

  • Smaller periods of data collection over shorter intervals

  • Smaller periods of data collection over larger intervals

  • Larger periods of data collection over larger intervals

Explicação

Questão 5 de 115

1

You are gathering data from a customer environment. You have to process a number of
configuration reports. What tool provides a simple method of processing the data
gathering configuration?

Selecione uma das seguintes:

  • Unisphere Analyzer

  • Collect Support Materials

  • E-Lab Advisor

  • CLARiiON Configuration Builder

Explicação

Questão 6 de 115

1

When interviewing customer personnel, you learn of two sets of requirements:
- The technical team has a specific set of requirements that they have to meet.
- The manager has a financial requirement that has to be met.
As you begin to design, it becomes clear that, in order to meet the technical goal, the
financial requirement will be exceeded. What should you do?

Selecione uma das seguintes:

  • Let both teams know of the constraints and see if there can be a mutual resolution.

  • Since this is a technical project you should design to the technical team requirements.

  • Because the manager is paying for the equipment, limit the design to fit into the
    financial constraints.

  • Design to the technical requirement and then take enough storage out to meet the
    financial goal.

Explicação

Questão 7 de 115

1

During your design analysis you have gathered current storage configuration data and
matched storage volumes with server data. You have discovered some inconsistencies
with the collected data. What should the next step be?

Selecione uma das seguintes:

  • Resolve any inconsistencies with the customer according to best practices.

  • Let the implementation engineer resolve the inconsistencies.

  • Note the inconsistencies and forward a redesign to the implementation engineer.

  • Resolve the inconsistencies yourself according to best practices.

Explicação

Questão 8 de 115

1

Which protocols are the best solution for Grid Computing and High Performance
Computing environments?

Selecione uma das seguintes:

  • iSCSI, FCoE

  • pNFS, MPFS

  • CIFS, NFS

  • FTP, SMB2

Explicação

Questão 9 de 115

1

Which RecoverPoint/SE data protection methodology enables block protection as well
as a file DR solution?

Selecione uma das seguintes:

  • RecoverPoint/SE CRR

  • RecoverPoint/SE CLR

  • RecoverPointt/SE CDP

  • RecoverPoint/SE CDP and CRR

Explicação

Questão 10 de 115

1

When documenting the customer environment prior to a storage refresh, you discover
that the customer has an issue their backups do not complete every job. How should you
proceed?

Selecione uma das seguintes:

  • Have the customer resolve the issue before continuing.

  • Note the issue in the Statement of Work and continue with planning.

  • Open a case for the backup issue and resolve it yourself.

  • No actionrequired:SOW does not include resolving this type of issue.

Explicação

Questão 11 de 115

1

Your customer has purchased a VNX to upgrade the storage for an Exchange Server
cluster. What tool should you use to gather performance data from the Exchange cluster?

Selecione uma das seguintes:

  • iostat

  • sar

  • esxtop

  • perfmon

Explicação

Questão 12 de 115

1

While gathering existing customer environment information to provide a new VNX
storage system solution, you have found many different HBA types, servers, operating
systems, and other SAN hardware. Which wizard within E-Lab Navigator can be used to
validate a new VNX storage solution?

Selecione uma das seguintes:

  • SOE & Software Wizard

  • CLARiiON Host Attach Wizard

  • Switch Interoperability Wizard

  • Storage Array Wizard

Explicação

Questão 13 de 115

1

Your customer needs help understanding Unisphere statistics on a VNX, specifically the
Number of Write Cache Pages. How do you explain this metric to the customer?

Selecione uma das seguintes:

  • It is displayed per each SP, and the total number is derived from the sum of both SPs.

  • It is displayed per entire array, and the total number is half the sum of both SPs.

  • It is displayed per each SP, and the total number is four times the sum of both SPs.

  • When FAST Cache is enabled, the number includes the FAST Cache plus the sum of
    both SPs.

Explicação

Questão 14 de 115

1

A customer wants to write a script that needs to list all linked remote VNX arrays for
file-based replication. What CLI command should you recommend?

Selecione uma das seguintes:

  • nas_cel -list

  • nas_cel -info

  • nas_replicate -info

  • nas_replicate -list

Explicação

Questão 15 de 115

1

You are preparing a detailed VNX presentation for a technically-oriented customer.
VNX arrays have been in their environment for over a year. One objective of the
meeting is to go over historical data. The customer indicated that they would like to see
Unisphere statistics as part of the analysis. Assuming that statistics logging was enabled
from day one, how long does the Unisphere GUI keep its real-time statistics?

Selecione uma das seguintes:

  • Real-time statistics are stored for 1 month.

  • Real-time statistics cannot be saved to disk.

  • Real-time statistics are stored for 3 months, unless the frequency interval is less than
    5 minutes.

  • Real-time statistics are stored indefinitely, but requires a dedicated collection server.

Explicação

Questão 16 de 115

1

You are gathering data on a customer's VNX for analysis. Which Navisphere Secure
CLI command can be used to display cumulative numbers for Total Reads and Total
Writes?

Selecione uma das seguintes:

  • getcontrol

  • getcache

  • getlun

  • getdisk

Explicação

Questão 17 de 115

1

A customer is experiencing a performance issue with a specific VNX file system.
Analyzer showed that the utilization of several RAID Groups was in the red. The
problematic file system, however, was mapped only to one of those RAID Groups, while
other RAID Groups served file systems without known issues. How would you explain
utilization metric to this customer?

Selecione uma das seguintes:

  • Utilization is a calculated number that determines how busy an object is, and it is
    likely to be too high rather than too low.

  • Utilization is a derived number that carries very little weight, and it is likely to be too
    low rather than too high.

  • Utilization is a calculated number that is used only for the internal spinning disk
    write/read adjustment algorithms, and it is always definitive.

  • Utilization is a metric showing the ratio between capacity and spinning speed. When
    high, it is an indicator that a particular disk should be replaced.

Explicação

Questão 18 de 115

1

A customer is questioning whether their Unified VNX configuration is compliant with
EMC VNX best practices. To start your evaluation, what information will you ask the
customer’s storage administrator to provide?

Selecione uma das seguintes:

  • VNX Qualifier; Collect support materials; and analyzer NAR files

  • NAR data; EMC grabs; and HEAT reports

  • ArrayConfig; VNX parameter list; and Active Directory information

  • Collect support materials; ArrayConfig; and EMC grabs

Explicação

Questão 19 de 115

1

A customer plans on using parallel NFS (pNFS) with the VNX. Which EMC document
should be used to validate VNX support for pNFS?

Selecione uma das seguintes:

  • EMC VNX support matrix

  • EMC published white paper

  • EMC training materials

  • EMC support email

Explicação

Questão 20 de 115

1

You have advised your customer to upgrade their current CLARiiON storage array
before migrating to a new VNX. The customer would like additional information about
what benefits the upgrade will provide. Where can you find information on known and
fixed problems for EMC products?

Selecione uma das seguintes:

  • Release Notes

  • Simple Support Matrix

  • E-Lab Navigator

  • E-Lab Analyzer

Explicação

Questão 21 de 115

1

Which two scopes are only used by a VNX system while logging into USM?

Selecione uma das seguintes:

  • Local, LDAP

  • Global, LDAP

  • Global, Local

  • Local, Kerberos

Explicação

Questão 22 de 115

1

Your customer is looking to consolidate their current Windows CIFS server virtualized
on VMware to a purpose built file sharing device. Their environment consists oF.
- 250-300 power users leveraging complex macros and import data from other
applications
- 15000-18000 average users leveraging home directories
- Some files are shared between their Windows and Red Hat application teams.
What key information should be collected to size and configure the VNX for their multi-
protocol shares?

Selecione uma das seguintes:

  • Windows and NFS client/server version information
    Active Directory Version information and number of domains
    User mapping tools
    Average number of files per server and average file size
    Total storage used esxtop data

  • Windows and NFS client/server version information
    Active Directory Version information and number of domains Average number of files
    per server and average file size Backup configuration, total storage used
    Anti-virus version
    DASD RAID Configuration

  • Windows and NFS client/server version information
    Active Directory Version information and number of domains
    User mapping tools
    Average number of files per server and average file size
    Total storage used Anti-virus version

  • Windows and NFS client/server version information
    Active Directory Version information and number of domains
    User mapping tools
    Average number of files per server and average file size
    Total storage used perfmon/iostat data

Explicação

Questão 23 de 115

1

You are doing performance analysis on a VNX5100 that is configured with three virtual
pools. You determine that FAST Cache would benefit overall performance. Why are you
unable to configure FAST Cache on the array?

Selecione uma das seguintes:

  • Virtual pools have already been enabled.

  • Cache memory needs to be disabled.

  • Cache memory needs to be enabled.

  • Engineering mode isrequiredto enable FAST Cache.

Explicação

Questão 24 de 115

1

A customer wants your help in deciding if their existing VNX array can be used to do
back up to disk, instead for tape backups. The customer has a unified VNX that is fully
populated with 125 disks. When looking at analyzer data for the array, you see that it has
a consistent utilization of over 70% on both SPs. According to EMC best practices, what
do you recommend to your customer?

Selecione uma das seguintes:

  • The array should not take on additional load.

  • The VNX is not supported as a backup-to-disk target.

  • The array can be used, but they must add an additional SP to the array.

  • The array can be used, but they will need an additional blade.

Explicação

Questão 25 de 115

1

You are planning a technical refresh of a customer's CLARiiON storage array to a VNX.
They have stated that the CLARiiON seems to perform slowly and believe that they
require additional disk spindles to satisfy their performance requirements. What utility
should you use to investigate performance trends?

Selecione uma das seguintes:

  • SP Collect

  • Network Storage Designer

  • Unisphere Analyzer

  • E-Lab Advisor

Explicação

Questão 26 de 115

1

Your customer has established a new virtual pool of storage containing NL-SAS drives
in a RAID 5 configuration. Recently they have noticed that performance on the entire
array is affected between 1:00AM and 4:00AM. What information would best indicate
the root cause?

Selecione uma das seguintes:

  • More than 21 forced flushes per second

  • SP utilization greater than 71%

  • Large sequential writes

  • HWM set to 60%; LWM set to 40%

Explicação

Questão 27 de 115

1

You are reviewing log files for a customer’s application using Analyzer, and note the
followinG.
- NFS write size is 8 KiB LUN
- Write size is 8 KiB
- Disk write size is 32 KiB
You can see that LUN write sizes are identical at 8 KiB. Why is the application not
writing at 32 KiB?

Selecione uma das seguintes:

  • No coalescing of data is occurring.

  • Data access is sequential.

  • Cache is being dumped.

  • The HWM value is too high.

Explicação

Questão 28 de 115

1

A customer is troubleshooting performance issues on a newly implemented VNX array.
They have asked you how to check LUN SP ownership and the performance of
individual disks. Which tool would you recommend?

Selecione uma das seguintes:

  • ControlCenter Performance Manager

  • Workload Analyzer

  • Navisphere Manager

  • Unisphere Analyzer

Explicação

Questão 29 de 115

1

Refer to the exhibit.
A customer is analyzing the size of data sent to disk. Which command generated the
output?

Selecione uma das seguintes:

  • naviseccli -h spa getdisk

  • nas_disk -info

  • naviseccli -h spa getlun

  • server_stats -monitor

Explicação

Questão 30 de 115

1

You are reviewing a NAR file and notice that a LUN has a write cache hit ratio of 0.0.
How can you tell if write cache is enabled for the LUN?

Selecione uma das seguintes:

  • Check for forced flushes.

  • Check the LUN write-aside value.

  • Check for reads satisfied by the read cache.

  • Check the SP Properties page.

Explicação

Questão 31 de 115

1

Your customer is designing a newly purchased VNX with 30 NL-SAS drives. The
customer's requirements in order of priority are 1) data availability and 2) performance.
What RAID type do you recommend?

Selecione uma das seguintes:

  • RAID 5

  • RAID 1/0

  • RAID 3

  • RAID 6

Explicação

Questão 32 de 115

1

During a customer data gathering meeting, a discussion about applications was
presented. Most of the applications will best be suited for a RAID 5 pool on the VNX.
However, one of the applications has an I/O requirement for RAID 1/0 spindles. How
should the RAID 1/0 application requirement be handled?

Selecione uma das seguintes:

  • Create two separate pools, one for RAID 5 and the other for RAID 1/0.

  • Combine the RAID 1/0 with the RAID 5 into one pool.

  • Create a large RAID 1/0 pool.

  • Create a large RAID 6 pool.

Explicação

Questão 33 de 115

1

Several Windows Server 2008 and RedHat Linux 5.5 servers are attached to VNX
storage arrays. PowerPath version 5.5 was installed on all Windows servers but not on
any of the Linux servers. Linux servers are using native MPIO for path failover. What
are the required failover modes for Windows Server 2008 and RedHat Linux 5.5
servers?

Selecione uma das seguintes:

  • Failover mode 1 for Windows Server 2008
    Failover mode 4 for RedHat Linux 5.5

  • Failover mode 4 for Windows Server 2008
    Failover mode 1 for RedHat Linux 5.5

  • Failover mode 1 for Windows Server 2008
    Failover mode 1 for RedHat Linux 5.5

  • Failover mode 4 for Windows Server 2008
    Failover mode 4 for RedHat Linux 5.5

Explicação

Questão 34 de 115

1

Several Windows servers are allocated storage from the VNX array. The customer
would like to know whether any of these servers are subject to disk crossing. What tools
are available to verify this condition?

Selecione uma das seguintes:

  • Unisphere Analyzer and NaviSecCLI

  • Navisphere Analyzer and NaviSecCLI

  • ECC Performance Manager and Navisphere Analyzer

  • ECC Performance Manager and Work Load Analyzer

Explicação

Questão 35 de 115

1

Your customer wants to add Flash drives to their VNX array and use them as FAST
Cache. They have specified that they want at least 150 GB of actual FAST Cache
capacity on each SP. There are no Flash drives in the array and they want to follow
EMC best practices on hot spares. How can this be achieved?

Selecione uma das seguintes:

  • Five 200 GB Flash drives

  • Three 200 GB Flash drives

  • Five 100 GB Flash drives

  • Four 200 GB Flash drives

Explicação

Questão 36 de 115

1

Your customer has recently purchased nine VNX arrays. They would like to utilize their
current single Tier 2 backup server to back up the Tier 2 LUNs on all nine arrays, and
would like to remain aligned with EMC best practices. What is your recommendation?

Selecione uma das seguintes:

  • Maximum Fibre Channel fan-out rule should be limited to 8 arrays.

  • Maximum Fibre Channel fan-in rule should be limited to 4 arrays.

  • Maximum Fibre Channel fan-in rule should be limited to 8 arrays.

  • Maximum Fibre Channel fan-out rule should be limited to 4 arrays.

Explicação

Questão 37 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer has four (4) LUNs
of 500 GiB each, six (6) LUNs of 250 GiB each, and five (5) LUNs of 100 GiB each.
All the drives presently in their VNX system are SAS and NL-SAS. They wish to
implement FAST Cache. Your data collection shows the skew to be 95%. What is the
minimum size of FAST Cache recommended for this environment?

Selecione uma das seguintes:

  • 200 GiB

  • 100 GiB

  • 400 GiB

  • 500 GiB

Explicação

Questão 38 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer has 6 LUNs of
500 GiB each, 6 LUNs of 250 GiB each, and 15 LUNs of 100 GiB each. All the drives
presently in their VNX system are SAS and NL-SAS. They wish to implement FAST
Cache. Your data collection shows the skew to be 94%. What is the minimum
recommended size of FAST Cache for this environment?

Selecione uma das seguintes:

  • 400 GiB

  • 100 GiB

  • 200 GiB

  • 500 GiB

Explicação

Questão 39 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer has a
heterogeneous pool with the following configuration:
- 800 GiB of Flash, with 300 GiB free
- 12,000 GiB of SAS, with 2,000 GiB free
- 50,000 GiB of NL-SAS, with 25,000 GiB free
The customer creates a new LUN with data placement policy set to "highest available
tier". The LUN is then populated with 600 GiB of data. How is that data distributed
(numbers are approximate)?

Selecione uma das seguintes:

  • 220 GiB on Flash, 380 GiB on SAS, no data on NL-SAS

  • 300 GiB on Flash, 400 GiB on SAS, no data on NL-SAS

  • 200 GiB on Flash, 200 GiB on SAS, 200 GiB on NL-SAS

  • 10 GiB on Flash, 110 GiB on SAS, 480 GiB on NL-SAS

Explicação

Questão 40 de 115

1

Your customer's IT group configured a VNX array and created multiple RAID 5 (2+1)
RAID Groups. They just realized their mistake and bought new drives. How would you
bring the customer into compliance with EMC best practices with minimal impact?

Selecione uma das seguintes:

  • Create RAID-5 (4+1) groups with new drives; migrate LUNs to new RAID Groups.

  • Use the new drives to expand existing RAID-5 Groups to RAID-5 (4+1) Groups.

  • Back up all data to tape; then destroy and re-create RAID Groups with RAID-5 (4+1)
    RAID Groups.

  • Buy a new VNX configured with RAID-5 (4+1) and use SAN Copy to migrate the
    data.

Explicação

Questão 41 de 115

1

Your customer has two clustered SQL servers that require direct access to LUNs located
on their VNX storage array. Both servers are located in the customer's main office. The
VNX storage array is located in the customer's data center, which is approximately 1.5
km from their office. Both facilities are interconnected using their existing IP network.
Which protocol should be used to connect the servers to the storage array?

Selecione uma das seguintes:

  • FC

  • iSCSI

  • CIFS

  • FCIP

Explicação

Questão 42 de 115

1

Your customer needs to add additional capacity to their existing FAST VP which
currently contains four Flash drives in a RAID 5 configuration. Which configurations
can be added to this pool?

Selecione uma das seguintes:

  • Five SAS drives in a RAID 5 configuration

  • Four Flash drives in a RAID 1/0 configuration

  • Six Flash drives in a RAID 6 configuration

  • Four SAS drives in a RAID 1/0 configuration

Explicação

Questão 43 de 115

1

Your customer has just purchased a new VNX, which will be dedicated to their large
SQL 2008 cluster. High-performance and high-availability are critical. To meet their
availability requirements, the customer has requested the configuration be optimized to
allow both storage processors to process I/O for any given LUN without trespassing the
LUN. Which configuration best supports their availability requirements?

Selecione uma das seguintes:

  • Failover Mode 4

  • Failover Mode 1

  • Failover Mode 2

  • Not supported on VNX platform

Explicação

Questão 44 de 115

1

Your customer has just purchased ten 1TB NL-SAS drives for their VNX array. This
additional capacity will be used to archive their large image repository. Which
configuration will provide the most efficient use of capacity while still following best
practices?

Selecione uma das seguintes:

  • Two RAID Groups with five drives each in a RAID 5 configuration

  • One RAID Group with ten drives in a RAID 1/0 configuration

  • One RAID Group with ten drives in a RAID 6 configuration

  • Two RAID Groups with five drives each in a RAID 6 configuration

Explicação

Questão 45 de 115

1

After reviewing the design for their new VNX, your customer has requested further
explanation of the hot spare algorithm used by the array. You propose the following
scenario: RAID group 200 consists of five 600 GB 10K SAS drives in a RAID 5
configuration. Within this RAID group there are three 25 GiB LUNs. One of the five
drives has just failed. In your scenario, which hot spare drive would the array first select
to replace the failed drive?

Selecione uma das seguintes:

  • SAS: 300 GB

  • SAS: 600 GB

  • NL-SAS: 2 TB

  • EFD.100 GB

Explicação

Questão 46 de 115

1

Your customer is designing a VNX file system using CIFS quotas with a supported
third-party application. What software option is required to support this implementation?

Selecione uma das seguintes:

  • VEE

  • VAVA

  • VEPA

  • CEPA

Explicação

Questão 47 de 115

1

Your customer is implementing a Unified VNX system leveraging CIFS general purpose
file shares. They are implementing all virtual provisioning and FAST features to
maximize storage efficiency. Which recommendations are made when leveraging virtual
provisioning?

Selecione uma das seguintes:

  • Either the file system or the underlying LUN in a FAST pool should be thin, but not
    both.

  • The underlying LUN in a FAST pool should be thin and have FAST Cache enabled.

  • Either the file system or the underlying LUN in a FAST pool should be thin, as long
    as FAST Cache is enabled.

  • Use thin provisioning at the file level and thick LUNs within a FAST pool of storage.

Explicação

Questão 48 de 115

1

Refer to the exhibit.

While trying to maximize availability for CIFS clients, the customer has designed the
following 10 Gb/s IP environment. What would you change in this design?
a. Ensure every connection has a failover to another switch.
b. Two Nexus switches are needed and the connection to the third switch removed.
c. Add three more connections to the VNX.
d. Change from LACP to EtherChannel for higher performance.
e. Upgrade to a VNX7500 to provide additional Data Movers.

Selecione uma das seguintes:

  • a) and b)

  • a) and b) and c)

  • b) and d)

  • c) and d) and e)

Explicação

Questão 49 de 115

1

You get a call from the customer asking about Active Directory integration for user
mapping. They have used EMC NAS products for over ten years and have extended the
schema some years ago. Now they are trying to migrate to default Windows Services for
UNIX (SFU, aka IDMU) for the UID/GID needs. Which statement best describes the
choices available?

Selecione uma das seguintes:

  • Old EMC domain schema extension and SFU are not overlapping, and can co-exist.
    The SID/UID data between them must be migrated manually.

  • Old EMC domain schema extension and SFU are overlapping, and can co-exist. The
    SID/UID data between them can be migrated automatically.

  • Old EMC domain schema extension and SFU are not overlapping, and cannot co-
    exist. The SID/UID data between them must be migrated manually.

  • Old EMC domain schema extension and SFU are overlapping, and cannot co-exist.
    The SID/UID data between them cannot be migrated at all due to different formats.

Explicação

Questão 50 de 115

1

A customer is concerned about UserMapper database and asks you what will happen to
the VNX CIFS users if UserMapper is unavailable. What do you advise them?

Selecione uma das seguintes:

  • All users will be affected.

  • Only new users will be affected.

  • Only UNIX users will be affected.

  • All CIFS users will be affected.

Explicação

Questão 51 de 115

1

Your customer has recently purchased a VNX for File. Due to the budget limits, they
were unable to purchase enough SAS drives to create all of their required file shares.
They would like to use their NL-SAS drives but are concerned about lower performance.
What EMC solution do you propose?

Selecione uma das seguintes:

  • Configure Cloud Tiering Appliance to archive data to the NL-SAS

  • Provision thin LUNs using a FAST-VP pool with the SAS and NL-SAS drives.

  • Allocate the SAS drives for file and use the NL-SAS drives for snapshots.

  • Configure Cloud Tiering Appliance to migrate data to the NL-SAS

Explicação

Questão 52 de 115

1

Your customer is designing a CIFS application with very specific high CIFS I/O
requirements.m What is the best recommendation when designing the CIFS storage
pool?

Selecione uma das seguintes:

  • RAID 1/0 MVM storage pool with 15K RPM drives

  • RAID 1/0 AVM storage pool with 15K RPM drives

  • RAID 5 AVM storage pool with 15K RPM drives

  • RAID 5 user-defined storage pool with SAS drives

Explicação

Questão 53 de 115

1

You are planning a file-only implementation where the customer will be using AVM.
You want to make the best use of storage pools to preserve the performance of VNX.
Which statement offers the best storage pool guidance for file system creation with AVM?

Selecione uma das seguintes:

  • Balance between two storage pools of the same disk type.

  • Use a storage pool of at least two disk types for tiering.

  • Span across storage pools of different disk types for tiering.

  • Use a single storage pool of the same disk type.

Explicação

Questão 54 de 115

1

Your customer is using the front-end iSCSI ports on their VNX. They are experiencing
long delays and reduced bandwidth as they add servers to their environment. Which
option will increase the customer's overall bandwidth while maintaining EMC best
practices for iSCSI?

Selecione uma das seguintes:

  • Increase the MTU to the maximum supported size allowed by the host and switch.

  • Enable Delayed ACK to allow the VNX to process the I/O before sending
    acknowledgment.

  • Increase the MTU to the maximum iSCSI limit to allow for maximum bandwidth.

  • Enable Pause Frames to allow the VNX to process all current I/O before new requests
    are accepted.

Explicação

Questão 55 de 115

1

Your customer currently has a Block-only VNX. They now want to add file services to
replace an older Windows Server cluster. You are planning to add the file option to the
current configuration. Where in the configuration do the Control LUNs for file reside?

Selecione uma das seguintes:

  • On the vault LUNs

  • On the vault drives

  • On any five contiguous disks on any enclosure

  • On any four contiguous disks on any enclosure

Explicação

Questão 56 de 115

1

A customer created a user-defined storage pool to physically segregate the file systems
of a business unit. The customer was careful to select LUNs from different RAID
Groups for the user- defined pool. After creating a file system from this storage pool
with AVM, the customer discovered that the file system was created on a single LUN
instead of multiple LUNs for better performance. What do you recommend to make
AVM use multiple LUNs when creating a file system from the user-defined pool?

Selecione uma das seguintes:

  • Stripe LUNs before adding them to the user-defined pool.

  • Specify file system size greater than any single LUN size.

  • Define the file system type to be MPFS.

  • Use the "slice=yes" option for the file system.

Explicação

Questão 57 de 115

1

You are asked to design the backend layout for a large Unified Storage VNX. You find
that the customer intends to use most of the disk space for block-level devices in the
SAN. How should NAS RAID Groups be selected on the array for optimum AVM
performance?

Selecione uma das seguintes:

  • Evenly, across as many backend busses as possible.

  • Take all from one bus before going to the next bus.

  • Use the odd-numbered busses while staying off the zero-bus.

  • Take all from two busses before going to the next pair.

Explicação

Questão 58 de 115

1

A customer has an existing Unified VNX which is used only for block data. They are
now looking to consolidate a few Windows servers onto the VNX. There is empty space
on existing pools, which the customer is planning to use for file storage. What would
you advise the customer?

Selecione uma das seguintes:

  • Sharing pools is recommended by all performance experts.

  • Microsoft doesn't recommend sharing pools between servers and clients for better
    correlation of I/O requests.

  • Although not explicitly prohibited, best practices advises against sharing pools.

  • Sharing pools is permitted as long as file data consists mostly of sparse files.

Explicação

Questão 59 de 115

1

Your customer has recently deployed MS SharePoint using MS SQL as the backend
database. Their deployment has grown to over 1 TiB in size and continues to increase
approximately 10% per month. Their users have reported performance issues. What
configuration using externalization of BLOB data should you recommend?

Selecione uma das seguintes:

  • RAID 6 with NL-SAS drives

  • RAID 5 with NL-SAS drives

  • RAID 5 with SAS drives

  • RAID 6 with SAS drives

Explicação

Questão 60 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer has an application
requirement of 3000 IOPS with 60/40 read/write ratio and with 5 TiB storage capacity.
The I/O is random. The customer is concerned about cost. You are proposing VNX with
300 GB 10K SAS drives. What should the proposed configuration be to minimize the
costs with EMC best practices in mind?

Selecione uma das seguintes:

  • RAID 1/0 with 38 drives

  • RAID 5 with 25 drives

  • RAID 5 with 45 drives

  • RAID 1 with 24 drives

Explicação

Questão 61 de 115

1

A customer is considering the VNX to support the SQL environment. What storage
feature of the VNX provides the best performance for the SQL application?

Selecione uma das seguintes:

  • RAID Group LUNs

  • FAST VP

  • FAST Cache

  • Thin pool LUNs

Explicação

Questão 62 de 115

1

A customer is planning on migrating their Exchange data to a VNX array. You have
gathered the following information:
- 6000 IOPS; 50% read/write ratio
Calculating for RAID 5, what is the minimum number of 15K SAS drives required?

Selecione uma das seguintes:

  • 84

  • 100

  • 34

  • 96

Explicação

Questão 63 de 115

1

A customer has the following requirements for their ESX environment:
- Three 500 GiB datastores
- One 1 TiB datastore
- One 7 TiB datastore
Based on the datastore information, what would you recommend?

Selecione uma das seguintes:

  • CIFS

  • File iSCSI

  • Block iSCSI

  • NFS

Explicação

Questão 64 de 115

1

After deploying their new VNX, your customer has inquired about features and tools to
optimize their VMware environment. Which tools or feature enables efficient SCSI
LUN reservation methods and reduces I/O traffic during cloning or zeroing operations?

Selecione uma das seguintes:

  • vStorage APIs for Array Integration (VAAI)

  • PowerPath/VE

  • Replication Manager

  • Virtual Storage Integrator (VSI)

Explicação

Questão 65 de 115

1

Click on the calculator icon in the upper left-hand corner. Your customer has the
following requirements for their CIFS home directories:
- Checkpoint every 10 minutes
- Data retention 24-hours
- Self-service file-level recovery
Which checkpoint interval in minutes should you recommend?

Selecione uma das seguintes:

  • 20

  • 30

  • 60

  • 45

Explicação

Questão 66 de 115

1

A customer has purchased a VNX array and is in the process of allocating RAID 5 (4+1)
storage. They have asked you for best practices on number and placement of LUNs for
the Reserved LUN pool. Which response provides the best answer?
B. Reserved LUNs can be of different sizes, but there should be no more than 25 in a
4+1 RAID 5 Group.

Selecione uma das seguintes:

  • All Reserved LUNs should be the same size, with no more than 25 in a 4+1 RAID 5
    Group.

  • All Reserved LUNs should be the same size, with no more than 15 in a 4+1 RAID 5
    Group.

  • Reserved LUNs can be of different sizes, but there should be no more than 15 in a
    4+1 RAID 5 Group.

Explicação

Questão 67 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer wants to add a
SnapView snapshot to a 500 GiB LUN. Captured data show that the LUN performs 500
4 KiB IOPs with a read/write ratio of 3:1. What is the expected initial bandwidth at
which data chunks will be written into the Reserved LUN Pool?

Selecione uma das seguintes:

  • 7.813 MiB/s

  • 3.906 MiB/s

  • 500 KiB/s

  • 2.125 MiB/s

Explicação

Questão 68 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer wants to add a
SnapView snapshot to a 600 GiB LUN. Captured data show that the LUN has an access
rate of 1000 IOPs with a read/write ratio of 4:1, and 8 KiB IOs. What is the expected
initial bandwidth at which data chunks will be written into the Reserved LUN Pool?

Selecione uma das seguintes:

  • 12.500 MiB/s

  • 1.563 MiB/s

  • 6.250 MiB/s

  • 25.000 MiB/s

Explicação

Questão 69 de 115

1

A snapshot is being used to perform a backup of the LUN. How can the backup activity
impact the host performance on the source LUN?

Selecione uma das seguintes:

  • Decreased write response times

  • Decreased read response times

  • Increased write response times.

  • Reads from snaps are faster than from source LUNs.

Explicação

Questão 70 de 115

1

A customer would like to implement SnapView but has expressed concern about
performance. Which applications will cause performance issues?

Selecione uma das seguintes:

  • Applications with small-block continuous writes

  • Applications with large-block random writes

  • Applications with large-block continuous writes

  • Applications with small-block random writes

Explicação

Questão 71 de 115

1

Click on the calculator icon in the upper left-hand corner. Customer requirements call
for a SnapView snapshot to be made of a clone prior to resynchronization. The source
LUN is 256 GiB, and performs 500 random reads/s and 25 random writes/s of 8 KiB.
The clone will be fractured every 15 minutes, and resynchronized after the snapshot is
started. How many COFWs will be performed each time the clone is resynchronized?

Selecione uma das seguintes:

  • 45,000

  • 22,500

  • 112,500

  • 56,250

Explicação

Questão 72 de 115

1

Click on the calculator icon in the upper left-hand corner. Customer requirements call
for a SnapView snapshot to be made of a clone prior to resynchronization. The source
LUN is 512 GiB, and performs 550 random reads/s and 10 random writes/s of 4 KiB.
The clone will be fractured every 10 minutes, and resynchronized after the snapshot is
started. How many COFWs will be performed each time the clone is resynchronized?

Selecione uma das seguintes:

  • 24,000

  • 12,000

  • 36,000

  • 48,000

Explicação

Questão 73 de 115

1

A customer requests to have 90 SnapSure checkpoints for every file system. After an
interview with the administrator, you learn that the company has to comply with an
industry requirement of keeping data on disk for a quarter. What approach solves the
requirement with least disk overhead?

Selecione uma das seguintes:

  • Create three checkpoint schedules:
    Snap a checkpoint every day, every even hour, keep 4. Snap a checkpoint Mon-Sat, at
    5pm, keep 6.
    Snap a checkpoint on Sun, at 6pm, keep 80.

  • Create four checkpoint schedules:
    Snap a checkpoint every day, every hour between 8am and 4pm, keep 7. Snap a
    checkpoint Mon-Sat, at 5pm, keep 6.
    Snap a checkpoint on Sun, at 5pm, keep 3.
    Snap a checkpoint every 1st of the month, at 6pm, keep 3.

  • Create two checkpoint schedules:
    Snap a checkpoint every day, every hour, keep 12. Snap a checkpoint Mon, at 5pm, keep

  • Create one checkpointschedule.
    Snap a checkpoint every day, at 5pm, keep 90.

Explicação

Questão 74 de 115

1

Your customer has recently seen a significant increase in overall useable capacity of
their CIFS file shares after enabling file-based deduplication. They have also noticed a
significant decrease in the overall available storage on the VNX system. What is the
most likely cause?

Selecione uma das seguintes:

  • Replicator is enabled.

  • Significant increase in user activity.

  • Checkpoints are disabled.

  • Recent restore of a file system.

Explicação

Questão 75 de 115

1

Your customer is running Exchange 2007 with VSS.

They have just purchased RecoverPoint/SE.
Which replication options are supported for their Exchange 2007 environment?

Selecione uma das seguintes:

  • Online full, online copy, online differential

  • Online full, offline copy, online differential

  • Offline full, online copy, online differential

  • Offline full, offline copy, online differential

Explicação

Questão 76 de 115

1

Your customer is planning to implement RecoverPoint for local replication. They have
several CLARiiON CX-4 arrays, two Celerras and a VNX array. They have the
following hosts in the environment: Windows (2003 and 2008), Linux and AIX. They
also use VMware. The customer wants to use host-based splitters Which version of
RecoverPoint should you recommend?

Selecione uma das seguintes:

  • RecoverPoint/SE CDP

  • RecoverPoint/SE CRR

  • RecoverPoint/SE CLR

  • RecoverPoint

Explicação

Questão 77 de 115

1

You have been working with a customer on sizing and implementing a RecoverPoint/SE
CDP solution into their environment. The customer calls you, wanting to know how they
can log in to the RecoverPoint application. What IP address should they use to
accomplish this?

Selecione uma das seguintes:

  • Management IP address for the RPA Cluster

  • Management IP address for the Control Station

  • IP address of the X-Blade

  • IP address of the RecoverPoint appliance

Explicação

Questão 78 de 115

1

Your customer plans to use Incremental SAN Copy as part of a DR solution. The Source
LUN is 512 GiB in size, and a clone of this LUN will be used as the ISC source LUN.

The host accessing the LUN generates 500 4 KiB IOPS with a R/W ratio of 3:1. The
clone is fractured every 30 minutes, and an ISC update is performed. How much data is
moved across the link in the 30-minute period?

Selecione uma das seguintes:

  • 900 MiB

  • 28 GiB

  • 56 GiB

  • 1800 MiB

Explicação

Questão 79 de 115

1

Your customer plans to use Incremental SAN Copy as part of a DR solution. The Source
LUN is 256 GiB in size, and a clone of this LUN will be used as the ISC source LUN.
The host accessing the LUN generates 500 4 KiB IOPS with a R/W ratio of 9:1. The
clone is fractured every 20 minutes, and an ISC update is performed. How much data is
moved across the link in the 20- minute period?

Selecione uma das seguintes:

  • 7.5 GiB

  • 240 MiB

  • 15 GiB

  • 480 MiB

Explicação

Questão 80 de 115

1

You are reviewing the MirrorView/S configuration on a VNX array. The source LUN is
a metaLUN. What is the best practice for FAST Cache for component LUNs of a
metaLUN source?

Selecione uma das seguintes:

  • Enable in all component LUNs.

  • Disable in all but the first component LUN.

  • Enable in all LUNs except the first component LUN.

  • Disable in all component LUNs.

Explicação

Questão 81 de 115

1

A customer has a 512 GiB primary MirrorView/S image. The image workload is 1,000
IOPs of random 4 KiB IOs, with a R/W ratio of 3:1. The secondary image is fractured

for 30 seconds as the result of a connectivity failure. How much data will be copied to
the secondary as part of the resynchronization process?

Selecione uma das seguintes:

  • 1.8 GiB

  • 3.0 GiB

  • 5.1 GiB

  • 10.0 GiB

Explicação

Questão 82 de 115

1

A customer has a 256 GiB primary MirrorView/S image. The image workload is 1,000
IOPs of random 8 KiB I/Os, with a R/W ratio of 3:1. The secondary image is fractured
for 20 seconds as the result of a connectivity failure. How much data will be copied to
the secondary as part of the resynchronization process?

Selecione uma das seguintes:

  • 5,120 MiB

  • 1,250 MiB

  • 2,560 MiB

  • 8,192 MiB

Explicação

Questão 83 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer has a 2 TiB LUN
which will be mirrored with MirrorView/S. Analyzer shows the current workload to be
500 8 KiB IOPs with a R/W ratio of 3:1. The customer requires that the mirror should
resynchronize within 2 hours if fractured for 10 minutes or less. How much bandwidth is
required to meet customer requirements?

Selecione uma das seguintes:

  • 10 Mb/s

  • 20 Mb/s

  • 54 Mb/s

  • 114 Mb/s

Explicação

Questão 84 de 115

1

Click on the calculator icon in the upper left-hand corner. A customer has a 1 TiB LUN
which will be mirrored with MirrorView/S. Analyzer shows the current workload to be

600 8 KiB IOPs with a R/W ratio of 2:1. The customer requires that the mirror should
resynchronize within 90 minutes if fractured for 15 minutes or less. How much
bandwidth is required to meet customer requirements?

Selecione uma das seguintes:

  • 182 Mb/s

  • 12 Mb/s

  • 48 Mb/s

  • 91 Mb/s

Explicação

Questão 85 de 115

1

Your customer wants to set up MirrorView/S between VNX arrays in their primary and
secondary data centers. The two data centers are located 50 kilometers apart. Both VNX
arrays are running Unisphere version 1.1. How can this be done?

Selecione uma das seguintes:

  • Using Navisphere Secure CLI

  • Using Unisphere GUI

  • Using Unisphere Service Manager

  • Using ESRS

Explicação

Questão 86 de 115

1

You are reviewing the array configuration of a VNX array that has MirrorView/A
enabled. You notice that all the images related to MirrorView/A have FAST Cache
disabled. What is the best practice for FAST Cache on MirrorView/A?

Selecione uma das seguintes:

  • Enable on source image and RLP LUNs.

  • Enable on source image.

  • Disable on source image.

  • Disable on source image and RLP LUNs.

Explicação

Questão 87 de 115

1

Click on the calculator icon in the upper left-hand corner. Your customer wants to use a
VNX system at an unmanned DR site. The system will be used exclusively as a
secondary MirrorView/A system, and it is capable of performing 30,000 LUN IOPs in
this role. The primary system is also a VNX. If the primary image workload consists of

4 KiB random IOs with a R/W ratio of 3:1, what is the maximum bandwidth required for
the link between the VNX systems?

Selecione uma das seguintes:

  • 240 Mb/s

  • 360 Mb/s

  • 480 Mb/s

  • 600 Mb/s

Explicação

Questão 88 de 115

1

Click on the calculator icon in the upper left-hand corner. Your customer wants to use a
VNX system at an unmanned DR site. The system will be used exclusively as a
secondary MirrorView/A system, and it is capable of performing 60,000 LUN IOPs in
this role. The primary system is also a VNX. If the total primary image workload
consists of 1 KiB random I/Os with a R/W ratio of 3:1, what is the maximum bandwidth
required for the link between the VNX systems?

Selecione uma das seguintes:

  • 240 Mb/s

  • 120 Mb/s

  • 360 Mb/s

  • 600 Mb/s

Explicação

Questão 89 de 115

1

How is RPO calculated in MirrorView/A environments?

Selecione uma das seguintes:

  • Half the update cycle

  • Chunks used divided by link bandwidth

  • Twice the update cycle

  • Blocks transferred divided by link bandwidth

Explicação

Questão 90 de 115

1

During data collection, the Time Out of Sync (TOS) setting is currently set at 10
minutes. You recommend a larger TOS setting based on the data that will be replicated.
Under what conditions would you increase the TOS setting?

Selecione uma das seguintes:

  • Source is prone to bursts of write activity.

  • Source is prone to bursts of read activity.

  • Source is prone to very low write activity.

  • Source is prone to very low read activity.

Explicação

Questão 91 de 115

1

A new customer is looking at purchasing two new VNXs and wants to replicate the
CIFS environment. What is a recommended configuration to have CIFS replicated?

Selecione uma das seguintes:

  • VDM

  • AVM

  • VSS

  • CRR

Explicação

Questão 92 de 115

1

Your customer calls you about their new replication solution. CIFS access is being
interrupted intermittently on the replication target. What would you recommend to avoid
interruption?

Selecione uma das seguintes:

  • Increase RPO to 20 minutes.

  • Disable Auto Extend on the source file system.

  • Use a checkpoint of the destination file system for client access at the destination site.

  • Use a checkpoint of the source file system for client access at the destination site.

Explicação

Questão 93 de 115

1

During a design session with the customer you discover a need to replicate the source
VNX to many locations for Disaster Recovery requirements. How many locations or
targets can Replicator support?

Selecione uma das seguintes:

  • 4

  • 6

  • 1

  • 2

Explicação

Questão 94 de 115

1

You have been asked to design a replication solution for file data. The replication will be
from a customer's remote data center to their primary data center. The distance between
the data centers is 1200 km. The initial synchronization is 125 Gb of data over a WAN
(1.2 Mb/s) with a 33 ms delay. Which replication solution supports the use of physical
media to transport the initial copy?

Selecione uma das seguintes:

  • VNX Replicator

  • RecoverPoint/SE CRR

  • RecoverPoint/SE CDP

  • SAN Copy

Explicação

Questão 95 de 115

1

During a design session with the customer, you determine that they require all tier one
LUNs on the production VNX be replicated to a remote VNX. They also require the
ability to be able to restore or mount the data at any given time during the day. What
replication technology would you recommend?

Selecione uma das seguintes:

  • SAN Copy

  • MirrorView/A

  • SnapSure

  • RecoverPoint

Explicação

Questão 96 de 115

1

A customer wants to use RecoverPoint/SE CRR. They have just realized that they need
to use RecoverPoint write splitters, but do not understand how they work. What does the
splitter do after it intercepts a write I/O meant for a RecoverPoint Protected LUN?

Selecione uma das seguintes:

  • It sends a copy to the local RecoverPoint appliance.

  • It sends the I/O to the local RecoverPoint appliance instead of the LUN.

  • It sends It sends the I/O to both the local and the remote RecoverPoint

  • It sends a copy to the remote RecoverPoint appliance.

Explicação

Questão 97 de 115

1

You are sizing a new RecoverPoint/SE CRR installation for a customer. You have
gathered data from their environment and have decided that they will need 142
consistency groups. How many RecoverPoint clusters at each site must you plan for?

Selecione uma das seguintes:

  • 2

  • 4

  • 6

  • 8

Explicação

Questão 98 de 115

1

You are sizing a new RecoverPoint/SE CRR installation for a customer. You have
gathered data from their environment and have decided that they will need 142
consistency groups. How many RecoverPoint appliances at each site must you plan for?

Selecione uma das seguintes:

  • 2

  • 6

  • 8

  • 4

Explicação

Questão 99 de 115

1

A customer is migrating NFS data off the legacy non-EMC array to the VNX. The
customer wants to keep downtime to a minimum. Which tool is best suited for this task?

Selecione uma das seguintes:

  • rsync

  • SAN Copy

  • emcopy

  • VNX Replicator

Explicação

Questão 100 de 115

1

A customer is migrating multiprotocol data off a NetApp array to a VNX. The customer
wants to keep downtime to a minimum. Which tool is best suited for this task?

Selecione uma das seguintes:

  • Cloud Tiering Appliance

  • SAN Copy

  • PPME

  • VNX Replicator

Explicação

Questão 101 de 115

1

A customer is planning on migrating fourteen Windows clusters onto a VNX. They want
to preserve all CIFS server names. Using best practices, which option would you
recommend?

Selecione uma das seguintes:

  • VNX doesn't support multiple CIFS instances: they need to consolidate into one.

  • Create a separate VDM for each CIFS server instance.

  • Add one more VNX array to the solution.

  • Place all CIFS server instances into one VDM.

Explicação

Questão 102 de 115

1

A customer is looking to migrate an existing VNX gateway from a CLARiiON CX-4
backend to a VMAX. Which migration option mitigates risk and requires the least
effort?

Selecione uma das seguintes:

  • Install a new VNX gateway to a VMAX, and use VNX Replicator to migrate the
    data.

  • Use SAN Copy to move all VNX LUNs to the VMAX.

  • Use the file system migration tool in Unisphere.

  • Use SAN Copy to move control LUNs to the VMAX, and use VNX Replicator to
    migrate data volumes.

Explicação

Questão 103 de 115

1

A customer is replacing a CLARiiON CX-4 array with a VNX array. SAN Copy Pull is
determined to be the best method to migrate the data. What is an advantage of using the
pull method in this scenario?

Selecione uma das seguintes:

  • Permits use of faster SPs

  • Faster transfer of data

  • Uses Incremental transfer

  • Higher load on the source array

Explicação

Questão 104 de 115

1

A customer has a VNX array replicating to a CX array using MirrorView/S. A new
VNX array will be installed and used for testing. A copy of the existing VNX/CX data
needs to reside on the new VNX array. Incremental SAN Copy will be used to perform
the copy. Which will be a valid source LUN for the migration?

Selecione uma das seguintes:

  • Reserved LUN pool LUN

  • Snapshot of MirrorView/S primary image

  • MirrorView/S secondary image

  • Snapshot of MirrorView/S secondary image

Explicação

Questão 105 de 115

1

Your customer has purchased a VNX and wants to migrate their block and file data from
their legacy integrated Celerra. They would like to use their existing EMC File
Management Appliance to migrate all of the data. What do you recommend?

Selecione uma das seguintes:

  • The File Management Appliance will not migrate block data.

  • The File Management Appliance will migrate block data.

  • You can only move one protocol with the File Management Appliance.

  • Incremental copies can be performed with the File Management Appliance.

Explicação

Questão 106 de 115

1

Your customer recently bought VNX storage array to consolidate multiple NetApp arrays.
The customer has Windows and UNIX servers as well NFS and CIFS file systems.
What migration tools are available to migrate the data from NetApp to VNX?

Selecione uma das seguintes:

  • Open Migrator for block; rsync and emcopy for file

  • Open Replicator and MirrorView for block; emcopy and CDMS for file

  • SAN Copy and Open Replicator for block; rsync for file

  • SAN Copy and SRDF for block; SecureCopy for file

Explicação

Questão 107 de 115

1

Customer has two data centers and acquired two VNX storage arrays in each data center
to consolidate their existing CLARiiON CX-4 arrays. One of the requirements is remote
replication using MirrorView. What are the front-end storage port restrictions?

Selecione uma das seguintes:

  • HBA Initiators and RecoverPoint cannot share the same SP ports.

  • HBA Initiators and MirrorView cannot share the same SP ports.

  • HBA Initiators and SAN Copy cannot share the same SP ports.

  • SAN Copy and MirrorView cannot share the same SP ports.

Explicação

Questão 108 de 115

1

Your customer has recently purchased a new VNX. They have chosen SAN Copy to
migrate data from their existing CLARiiON to the new VNX. The customer has stated
that only 50% of the capacity within each of the source LUNs is actually consumed.
Source LUNs are 500 GiB RAID 5 on 1 TB SATA disks. All LUNs and RAID Groups
on the source array are configured the same. Using best practices, which target LUN
configuration should you use?

Selecione uma das seguintes:

  • Target LUN must be equal to or greater than size of source LUN.

  • Target LUN must use same RAID type as source LUN.

  • Target LUN must use same disk type as source LUN.

  • Target LUN must be equal to or greater than consumed capacity of source LUN.

Explicação

Questão 109 de 115

1

You have decided to use SAN Copy to perform an incremental copy migration of your
customer's data. There are 25 source LUNs; each LUN is 250 GiB in size. The target
LUNs are each 300 GiB in size. Using best practices, what is the smallest sized LUN in
GiB you should use in the reserved LUN
pool for this migration?

Selecione uma das seguintes:

  • 25

  • 250

  • 30

  • 300

Explicação

Questão 110 de 115

1

When using SnapView, what happens when the Reserved LUNs assigned to a LUN
become 100% full?

Selecione uma das seguintes:

  • The SnapView Session is terminated and the Reserved LUNs have to be manually
    deleted

  • The SnapView Session is quiesced until the user adds more LUNs to the Reserved
    LUN Pool

  • The SnapView Session is quiesced and available LUNs from the Free LUNs section
    of the Reserved LUN Pool areassigned to the LUN

  • The SnapView Session is terminated and the Reserved LUNs are returned to the Free
    LUNs section of the Reserved LUN Pool

Explicação

Questão 111 de 115

1

When is the Copy on First Write mechanism enabled?

Selecione uma das seguintes:

  • When the SnapView session is started

  • When the SnapView session is being rolled back

  • When the Snapshot is activated

  • When the Snapshot is created

Explicação

Questão 112 de 115

1

What controls the reporting of events when using Event Monitor?

Selecione uma das seguintes:

  • Unisphere Agent

  • SP Agent

  • Host

  • VNX

Explicação

Questão 113 de 115

1

What is the function of Usermapper?

Selecione uma das seguintes:

  • Provides UIDs and GIDs for Windows SIDs

  • Allows UNIX users to access CIFS file systems

  • Maps CIFS users to file systems on VNX

  • Queries Windows Active Directory for users

Explicação

Questão 114 de 115

1

What VNX feature enables administrators to group file systems and CIFS servers into
virtual containers?

Selecione uma das seguintes:

  • VDM

  • VLAN

  • VM

  • VLAN tagging

Explicação

Questão 115 de 115

1

Which file protocol allows clients to access storage devices directly and in parallel?

Selecione uma das seguintes:

  • pNFS

  • MPFS

  • NFS

  • CIFS

Explicação