Chapter 9 - Quiz

Questão 1 de 20

1

For current-generation hydronic heating systems, the controlled variable is usually indoor air temperature.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 2 de 20

1

Most of the closed-loop control systems used for hydronic heating continually seek to eliminate any error that exists between the target value and measured value of the controlled variable.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 3 de 20

1

Heat output from the heat emitter occurs whenever the supply water temperature equals the room air temperature.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 4 de 20

1

The combination of near-continuous circulation and very gradual changes in water temperature tends to maximize expansion noises from the distribution piping and heat emitters.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 5 de 20

1

Most heat source reset controllers have an adjustable minimum supply temperature.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 6 de 20

1

Relay contacts are designated as normally open, or normally closed. In this context, the word "normally" means when the coil of the relay is not energized.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 7 de 20

1

There are hydronic heating applications where control action is required based on the difference between two temperatures rather than the value of either temperature.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 8 de 20

1

A multizone relay center is designed to isolate the wiring and control operation of several independent zone circulators or zone valves.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 9 de 20

1

One purpose of mixing is to protect conventional boilers from operating at conditions that allow sustained flue gas condensation.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 10 de 20

1

Direct injection mixing, whether accomplished using a two-way valve or variable-speed pump as the injection control device, provides the highest temperature difference between the supply and return injection risers.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 11 de 20

1

The proper documentation of control systems is essential if they are to be expediently serviced in the future. A universally accepted tool for such documentation is the __________.

Selecione uma das seguintes:

  • microprocessor

  • ladder diagram

  • designer spreadsheet

  • flow chart

Explicação

Questão 12 de 20

1

The term __________ differential refers to the actual variation in the controlled variable as the system operates.

Selecione uma das seguintes:

  • control

  • modulating

  • operating

  • real-time

Explicação

Questão 13 de 20

1

To provide accurate control under low-load conditions, the controlled device must be able to maintain stable flow at very low flow rates. Such a device is said to have good __________.

Selecione uma das seguintes:

  • modulation

  • variability

  • machining

  • rangeability

Explicação

Questão 14 de 20

1

As outdoor temperature increases, and the heating load decreases, the water temperature supplied to the heat emitters also decreases as does their heat output. This concept is called outdoor __________ control.

Selecione uma das seguintes:

  • temperature

  • variable

  • proportional

  • reset

Explicação

Questão 15 de 20

1

Switches and relays are classified according to their poles and throws. The number of __________ is the number of independent and simultaneous electrical paths through the switch.

Selecione uma das seguintes:

  • poles

  • throws

  • contacts

  • wires

Explicação

Questão 16 de 20

1

__________ control is a planned strategy for shedding (e.g., temporarily turning off) one or more loads when a specific condition is detected in the system.

Selecione uma das seguintes:

  • Error

  • Priority

  • Systemic

  • Conditional

Explicação

Questão 17 de 20

1

In addition to equal run time rotation, there are other operating options available for staged/modulating heat sources. They are called series staging/modulation, parallel staging/modulation, and __________ staging/modulation.

Selecione uma das seguintes:

  • proportional

  • on/off

  • multiple

  • hybrid

Explicação

Questão 18 de 20

1

Boiler protection is accomplished by __________ the rate of heat flow from the boiler into the distribution system whenever the boiler temperature approaches or falls below a specified minimum operating temperature.

Selecione uma das seguintes:

  • reducing

  • resetting

  • increasing

  • stabilizing

Explicação

Questão 19 de 20

1

The term injection mixing applies to any mixing assembly in which __________ is pushed (e.g., injected) into a circulating distribution system.

Selecione uma das seguintes:

  • coolant

  • air

  • hot water

  • mercury

Explicação

Questão 20 de 20

1

A network control system without Internet access requires a person to be present to interrogate or adjust the system. This is unnecessary with a(n) __________ networked control system.

Selecione uma das seguintes:

  • Web-enabled

  • electronic

  • electromechanical

  • fuzzy logic

Explicação