Chapter 11 - Quiz

Questão 1 de 20

1

A zone is any area of a building for which indoor air temperature is controlled by a single thermostat (or other type of temperature controller).

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 2 de 20

1

Different rooms within a single zone (e.g., controlled by a single thermostat) and supplied with the same water temperature cannot be maintained at different temperatures by adjusting the flow rate through individual heat emitters.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 3 de 20

1

If the heat emitters are connected in series , the system flow rate will pass through each heat emitter. If the heat emitters are connected in parallel, the flow rate through each heat emitter can be proportioned based on load using an equation.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 4 de 20

1

Given the surface area of their bodies, hydraulic separators should be insulated to minimize heat loss to their surroundings.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 5 de 20

1

Designers should think of hydraulic separation as a physical concept that must be accomplished as an all-or-nothing condition.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 6 de 20

1

When a circulator with the flat curve is used, the differential pressure across the circulator changes dramatically as zone circuits turn on and off.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 7 de 20

1

The electronically commutated motors and improved hydrodynamic design of current generation variable-speed pressure-regulated circulators provide wire-to-water efficiencies that are approximately double those of standard wet-rotor circulators with permanent split capacity.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 8 de 20

1

If a fixed-speed circulator is selected, a differential pressure bypass valve should be installed to reduce the potential for flow noise when only one or two zones are active.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 9 de 20

1

Over the last two decades, many heating professionals have come to recognize the failure of PEX and PEX-AL-PEX tubing as universal piping materials for residential and light commercial hydronic systems.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 10 de 20

1

Primary/secondary (P/S) piping is the only way to achieve hydraulic separation between simultaneously operating circulators.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 11 de 20

1

The time required to cool down or warm up a zone is significantly affected by the __________ of the heat emitter(s), and the building itself.

Selecione uma das seguintes:

  • thermal envelope

  • thermal mass

  • ambient temperature

  • setpoint temperature

Explicação

Questão 12 de 20

1

All hydronic systems, regardless of how they are designed or installed, attempt to simultaneously stabilize at two unique operating conditions called thermal equilibrium and __________ equilibrium.

Selecione uma das seguintes:

  • spatial

  • hydraulic

  • zoning

  • R-value

Explicação

Questão 13 de 20

1

In a technique known as __________, the designer repeatedly analyzes both the hydraulic and thermal performance of a system using "candidate" hardware options and operating conditions, until a combination is found that yields acceptable heat distribution.

Selecione uma das seguintes:

  • trial and error

  • selective pairing

  • elimination

  • iteration

Explicação

Questão 14 de 20

1

Ideally, each circulator in a system will establish a differential pressure and flow rates that is unaffected by the presence of another operating circulator within the system. This very desirable condition is called __________.

Selecione uma das seguintes:

  • hydraulic equilibrium

  • hydraulic separation

  • the pump curve

  • ideal circulation

Explicação

Questão 15 de 20

1

The degree to which two operating circulators interact with each other depends on the head loss of the piping path they have in common. This piping path is called the __________ piping.

Selecione uma das seguintes:

  • circulatory

  • serpentine

  • head loss

  • common

Explicação

Questão 16 de 20

1

The purpose of differential pressure bypass valves (DPBV) is to _________ the differential pressure imposed on the distribution system by a fixed-speed circulator as the system flow rate decreases due to closing zone valves.

Selecione uma das seguintes:

  • accelerate

  • equalize

  • limit

  • increase

Explicação

Questão 17 de 20

1

One approach that takes advantage of the flexibility of PEX or PEX-AL-PEX tubing is called a __________ distribution system.

Selecione uma das seguintes:

  • hydroplastic

  • home run

  • hybrid

  • green

Explicação

Questão 18 de 20

1

The closely spaced tees connecting a secondary circuit to the primary circuit are __________ when air is being purged from the system.

Selecione uma das seguintes:

  • counterproductive

  • instrumental

  • essential

  • irrelevant

Explicação

Questão 19 de 20

1

The concept of __________ provides a means by which the electrical energy consumption of a distribution system, per unit of heat delivery capacity, can be calculated and compared.

Selecione uma das seguintes:

  • hydraulic separation

  • hydraulic equilibrium

  • thermal envelope

  • distribution efficiency

Explicação

Questão 20 de 20

1

The diverse loads served by many modern residential and light commercial systems often dictate that the distribution system contains elements from __________ of the basic distribution systems discussed in this chapter.

Selecione uma das seguintes:

  • one specific

  • two or more

  • at least three

  • possibly none

Explicação