Ultrasound Physics Exam 1

Descrição

Ultrasound Physics Exam 1
Ayla Pitts
Quiz por Ayla Pitts, atualizado more than 1 year ago
Ayla Pitts
Criado por Ayla Pitts mais de 4 anos atrás
59
1

Resumo de Recurso

Questão 1

Questão
The frequency of a transducer does not change. If the diameter of the new piezoelectric crystal increase, what happens happens to the near zone length?
Responda
  • increases
  • decreases
  • no change

Questão 2

Questão
The frequency of a transducer does not change. If the diameter of the new piezoelectric crystal increases, what happens to the beam diameter in the far zone?
Responda
  • increases
  • decreases
  • no change

Questão 3

Questão
The frequency of a transducer does not change. If the diameter of the new piezoelectric crystals increases, what happens to wavelength?
Responda
  • increases
  • decreases
  • no change

Questão 4

Questão
The frequency of a transducer does not change. If the diameter of the new piezoelectric crystal increase, what happens to the beam diameter in the near zone?
Responda
  • increases
  • decreases
  • no change

Questão 5

Questão
At the location is the sound beam diameter three time greater than the transducer diameter?
Responda
  • at the end of the near zone
  • at the depth equal to four focal lengths
  • at the end of the far zone
  • at the triple-diameter depth

Questão 6

Questão
What is the shape of a sound beam created by a tiny piece of PZT?
Responda
  • hourglass shaped
  • V-shaped
  • round
  • shaped like a tube

Questão 7

Questão
Which of the following explains why a sound beam created by a disc-shaped crystal is hourglass-shaped?
Responda
  • Bernoulli's Principle
  • Sheffield's Law
  • Ohm's Law
  • Huygen's Principle

Questão 8

Questão
Which of the following locations is the deepest?
Responda
  • end of the fresnel zone
  • end of the focal zone
  • end of the fraunhofer zone
  • end of the near zone

Questão 9

Questão
Which of the following locations is the most shallow?
Responda
  • beginning of the far zone
  • beginning of the focal zone
  • focal depth
  • beginning of the Fraunhofer zone

Questão 10

Questão
A pair of 6MHz probes are identical excepts for the active element diameter. The active element diameters are 6mm and 10mm. The sound beam of which probe will have a shallower focus?
Responda
  • 6mm
  • 10mm

Questão 11

Questão
A pair of 9mm diameter probes are identical except for frequency, which is 3MHZ and 6MHz. WHich beam will have shallower focus?
Responda
  • 3MHz
  • 6MHz

Questão 12

Questão
Which of the following probes creates a beam with the deepest focus?
Responda
  • 4 mm diameter, 4 MHz
  • 6 mm diameter, 8 MHz
  • 4 mm diameter, 2 MHz
  • 5 mm diameter, 8MHz

Questão 13

Questão
Which of the following probes creates a beam with the shallowest focus?
Responda
  • 4 mm diameter, 4 MHz
  • 6 mm diameter, 8 MHz
  • 4 mm diameter, 2 MHz
  • 5 mm diameter, 8MHz

Questão 14

Questão
Which of the following probes creates a beam with a the shallowest focus?
Responda
  • small diameter, high frequency
  • large diameter, high frequency
  • small diameter, low frequency
  • large diameter, low frequency

Questão 15

Questão
Active elements diameter and near zone are directly related?
Responda
  • True
  • False

Questão 16

Questão
Transducer frequency and near zone length are inversely related.
Responda
  • True
  • False

Questão 17

Questão
Wavelength and near zone length are inversely related.
Responda
  • True
  • False

Questão 18

Questão
A pair of 6 MHz probes are identical excepts for the active element diameter, which is 6 mm and 10 mm. Which beam will be more compact in the far field?
Responda
  • 6 mm
  • 10 mm

Questão 19

Questão
A pair of 9 mm diameter probes are identical except for frequncies, which are 3 MHz and 6MHz. Which sound beam will spread out more in the far field>
Responda
  • 3 MHz
  • 6 MHz

Questão 20

Questão
Which of the following probes creates a beam with least divergence?
Responda
  • 4 mm diameter, 4MHz
  • 6 mm diameter, 8MHz
  • 6 mm diameter, 2MHz
  • 5 mm diameter, 8 MHz

Questão 21

Questão
Which of the following probes creates a beam with most divergence?
Responda
  • 4 mm diameter, 4 MHz
  • 6 mm diameter, 8 MHz
  • 4 mm diameter, 2 MHz
  • 5 mm diameter, 8 MHz

Questão 22

Questão
Which of the following probes create a beam with the most divergence?
Responda
  • small diameter, high frequency
  • large diamter, high frequency
  • small diameter, low frequency
  • large diameter, low frequency

Questão 23

Questão
Transducer frequency and beam divergence are inversely related
Responda
  • True
  • False

Questão 24

Questão
Active element diameter and beam divergence are inversely related.
Responda
  • True
  • False

Questão 25

Questão
Mechanical scanning and linear phased arrays create sector-shaped images
Responda
  • True
  • False

Questão 26

Questão
Many active elements fire at almost the same time in mechanical scanner.
Responda
  • True
  • False

Questão 27

Questão
Many active elements fire at almost the same time in a phased array scanner.
Responda
  • True
  • False

Questão 28

Questão
Which of the following transducers is best described as mechanically steered and fixed, single focused?
Responda
  • annular phased array
  • annular array
  • mechincal
  • linear phased

Questão 29

Questão
Which of the following is best described as mechanically steered and multi-focus?
Responda
  • annular phased array
  • annular sequential array transducer
  • mechanical transducer
  • linear phased transducer

Questão 30

Questão
Which of the following transducers creates a rectangular shaped image?
Responda
  • annular phased array
  • linear sequential array
  • mechanical
  • linear phased

Questão 31

Questão
A linear phased array transducer has 128 crystals. How many of these crystals are fired to create a single sound beam?
Responda
  • 1
  • a small group
  • a large group
  • 128

Questão 32

Questão
A linear sequential array transducer has 128 crystals. How many of these crystals are fired to create a single sound beam?
Responda
  • 1
  • a small group
  • 128
  • a large group

Questão 33

Questão
In a linear phased array, what is the firing patten that steers a beam to the left or right?
Responda
  • electronic slope
  • electronic curvature

Questão 34

Questão
In linear phased arrays, what is the firing pattern that focuses a sound beam?
Responda
  • electronic slope
  • electonic curvature

Questão 35

Questão
There are large time delays in the firing pattern of a linear phased array transducer.
Responda
  • True
  • False

Questão 36

Questão
A machine that displays A-mode and Two- dimensional image is called a duplex scanner.
Responda
  • True
  • False

Questão 37

Questão
A machine that displays a Doppler and two-dimensional images is called a duplex scanner.
Responda
  • True
  • False

Questão 38

Questão
Which of the following improves elevational resoultion?
Responda
  • matrix array
  • linear phased array
  • one and one-half dimensional arry
  • two-dimensional array

Questão 39

Questão
Side lobes degrade axial resolution
Responda
  • True
  • False

Questão 40

Questão
Side lobes degrade lateral resolution
Responda
  • True
  • False

Questão 41

Questão
Which of the following forms of resolution improve when frame rate increases?
Responda
  • lateral
  • temporal
  • spatial
  • longitudinal

Questão 42

Questão
Which of the following is consistent with improved temporal resolution?
Responda
  • color doppler
  • more grey shades
  • more detail
  • high frame rate

Questão 43

Questão
All of the following decrease temporal resolution except?
Responda
  • lower frame rate
  • deeper imaging
  • multi-focus
  • narrow sector

Questão 44

Questão
A sonographer adjusts an ultrasound scan to double the depth of view from 5 cm to 10 cm. What happens to the frame rate?
Responda
  • it is halved
  • it doubles
  • it increases from 5 to 10 Hz
  • it is unchanged

Questão 45

Questão
A sonographer adjusts an ultrasound scan to double the depth of view fro 5 cm to 10 cm. If the frame rate remains the same which on of the following also occurs?
Responda
  • increased line density
  • wider sector
  • multi-focus imaging turned one
  • narrow sector

Questão 46

Questão
A sonographer adjusts an ultrasound machine to change the sector siz for 90 to 45 degrees. Nothing else changes. What happends to the frame rate?
Responda
  • it is doubled
  • it remains unchaged
  • it is halved
  • it is tripled

Questão 47

Questão
A sonographer adjusts an ultrasound system to change the sector size for 90 to 45 degree. The frame rate was unchanged. What else must have happened?
Responda
  • temporal resolution was doubled
  • sector size was doubled
  • line density was doubled
  • imaging depth was halved

Questão 48

Questão
A sonographer using a phased array ultrasound system turns off the multi-focus feature. What is the most likely consequence of this action?
Responda
  • frame rate decreases
  • temporal resolution degrades
  • imaging depth increases
  • temporal resolution improves

Questão 49

Questão
A sonographer increases the line density from 1 line per degree of the sector to 3 lines per degree of the sector. What is the most likely consequence of this action?
Responda
  • frame rate increases
  • temporal resolution decreases
  • imaging quality decreases
  • temporal resolution increases

Questão 50

Questão
A sonographer reduces the sector angle for 90 degrees to 30 degrees. At the same time, the ultrasound system automatically increases the lines density from 1 line per degree to 2 lines per degree. No other change is made. What will happen to the frame rate?
Responda
  • increases
  • decreases
  • remains unchanged

Questão 51

Questão
A sonographer reduces the sector angle for 90 degrees to 30 degrees. At the same time, the ultrasound system automatically increases the lines density from 1 line per degree to 3 lines per degree. No other change are made. What will happen to temporal resolution?
Responda
  • increases
  • decreases
  • remains unchanged

Questão 52

Questão
Which of the following is most important in determinging the frame rate of a system?
Responda
  • speed of sound in the medium
  • dynamic range of the receiver
  • transducer frequency
  • transmitter output

Questão 53

Questão
Which of the following is most important in determining frame rate of a system?
Responda
  • depth of view
  • dynamic range of the receiver
  • transducer frequency
  • transmitter output

Questão 54

Questão
What is the frame rate if each image of the ultrasound system is created in 0.02 sec (1/50 sec)
Responda
  • 20 Hz
  • 100 Hz
  • 50 Hz
  • 16 Hz

Questão 55

Questão
What is the time needed to make a single image if the frame rate of an ultrasound system is 20 Hz?
Responda
  • 1 s
  • 0.02 s
  • 0.05 s
  • 15 Hz

Questão 56

Questão
The critical factor in determining frame rate, line density, and imaging depth is the tranducer style.
Responda
  • True
  • False

Questão 57

Questão
The number of lines per frame and the frame rate determine the frequency
Responda
  • True
  • False

Questão 58

Questão
The number of lines per frame and frame rate determine the PRF
Responda
  • True
  • False

Questão 59

Questão
If the imaging depth of a scan is 15 cm and there are 100 lines in the image, then the number of pulses making up the scan is 1500.
Responda
  • True
  • False

Questão 60

Questão
If the imaging depth of a scan is 15 cm and there are 100 lines in the image, then the number of pulses making up the scan is 100.
Responda
  • True
  • False

Questão 61

Questão
If 100 scan lines make up an image and the frame rate is 30 per second, then the transducer's frequency is 3,000 HZ
Responda
  • True
  • False

Questão 62

Questão
If 100 scan lines make up an image and the frame rate is 30 per second, then the system's PRF is 3,000 Hz
Responda
  • True
  • False

Questão 63

Questão
When the frame is 30Hz, how long does it take to create a frame?
Responda
  • 30 sec
  • 3 sec
  • 0.3 sec
  • 1/30 sec
  • 1/3 sec

Questão 64

Questão
Under certain conditions, an ultrasound system creates imagine in 0.01 seconds. What is the frame rate?
Responda
  • 1 Hz
  • 10 sec
  • 100 Hz
  • 200 Hz
  • 0.02 Hz

Questão 65

Questão
What is the fundamental limitation of temporal resolution?
Responda
  • imaging depth
  • speed of sound in the medium
  • line density
  • sector size

Questão 66

Questão
All of the following are components of an ultrasound system except?
Responda
  • transducer
  • alternator
  • display
  • pulser
  • synchronizer
  • receiver

Questão 67

Questão
This type of pulser generates a constant electrical signal in the form of a sine wave
Responda
  • pulsed wave, array
  • continous wave
  • pulsed wave, single crystal

Questão 68

Questão
This type of pulser generates a single electrical spike, which ultimately creates a single sound pulse.
Responda
  • pulse wave, phased array
  • continuous wave
  • pulsed wave, single crystal

Questão 69

Questão
This type of pulser generates numerous electrical spikes, which ultimately create a single sound pulse
Responda
  • pulsed wave, phase array
  • continous
  • pulsed wave, single crystal

Questão 70

Questão
The acoustic power of the sound beam emitted from a transducer is determined by the ________ of the pules's signal
Responda
  • PRF
  • Frequnecy
  • voltage
  • rectification

Questão 71

Questão
All of the following functions of the receiver except
Responda
  • demodulation
  • supression
  • amplification
  • attenutation

Questão 72

Questão
Amplification processes all reflected signals in a similar manner
Responda
  • True
  • False

Questão 73

Questão
Compensation processes all reflected signals in a similar manner
Responda
  • True
  • False

Semelhante

Mitologia Greco-latina: "Helena de Tróia"
Kika Martins
Expressões em inglês #1
Eduardo .
Direito Processual Penal
thiago.tc3
CONTABILIDADE DE CUSTOS (Samantha - Editar)
Samantha Iara Concolino
Quiz de biologia
Lafaiete
SEGUNDO REINADO
Lucas Villar
RESUMO DE LITERATURA (PARTE 1)
Ana Loss
Transformações Químicas e Físicas
Andrea Barreto M. Da Poça
SIMULADO - Casos Clínicos
Rodrigo Gouvea
Termodinâmica.
Giovanna Coelho Menezes
Metonímia
Diogo Alcantara