Questão 1

Questão
1. Which of the following types of intensifying screens are not used in industrial radiography?
Responda
  • (a) Lead
  • (b) Fluorescent
  • (c) Silver halide
  • (d) All of the above

Questão 2

Questão
2. Betatrons are used to produce X rays in what range?
Responda
  • (a) Several MeV
  • (b) 50-500 keV
  • (c) 500-1000 keV
  • (d) 0-50 keV

Questão 3

Questão
3. Which of the following is an isotope not artificially produced for industrial use:
Responda
  • (a) Ir-192
  • (b) Ra-226
  • (c) Co-60
  • (d) All of the above

Questão 4

Questão
4. One half value layer of lead for Iridium-192 is approximately:
Responda
  • 12 mm
  • 4 mm
  • 2 mm
  • 25 mm

Questão 5

Questão
5. One half value layer of lead for Cobalt-60 is approximately:
Responda
  • 12 mm
  • 6 mm
  • 2 mm
  • 25 mm

Questão 6

Questão
6. The film processing step in which the undeveloped silver bromide is removed from the film emulsion is called:
Responda
  • Development
  • Stop bath
  • Fixing
  • Rinsing

Questão 7

Questão
7. A radiation producing device which emits radiation of one or a few discreet wavelengths is:
Responda
  • An X ray machine
  • A linear accelerator
  • A gamma ray source
  • A betatron

Questão 8

Questão
8. The intensifying action of lead screens is caused by:
Responda
  • Secondary X ray emission
  • Secondary gamma ray emissions
  • Fluorescence of lead screens
  • Electron emission

Questão 9

Questão
9. Most of the energy applied to an X ray tube is converted into:
Responda
  • X rays
  • Light
  • Heat
  • Ultraviolet radiation

Questão 10

Questão
10. Radiography of tubular sections using a double wall, double viewing technique is mainly applicable to sections:
Responda
  • Over 38 mm in diameter
  • 88 mm in diameter or less
  • 125 mm in diameter and less
  • Under 25 mm in diameter

Questão 11

Questão
11. Which of the following is the most common method of packaging film?
Responda
  • (a) Individual sheets for use in cassettes
  • (b) Rolls
  • (c) Pre-packaged (‘day-pack’)
  • (d) All of the above

Questão 12

Questão
12. Which of the following types of radiation is particulate?
Responda
  • (a) X
  • (b) Gamma
  • (c) Alpha
  • (d) None of the above

Questão 13

Questão
13. Most scattered radiation which adversely affects the radiographic image quality originates:
Responda
  • (a) From floors and walls adjacent to the test piece
  • (b) From other nearby objects
  • (c) From the test piece itself
  • (d) From the lead intensifying screens

Questão 14

Questão
14. An effect of scattered radiation is to:
Responda
  • (a) Decrease required exposure time
  • (b) Diminish contrast, detail and clarity of radiographic image
  • (c) Decrease film density
  • (d) All of the above

Questão 15

Questão
15. What is the most important factor in determining the archival quality of radiographic film?
Responda
  • (a) Film density
  • (b) Image quality
  • (c) Degree of removal of fixer residues during washing
  • (d) Degree of removal of developer residues during washing

Questão 16

Questão
16. Radiographic enlargement to distinguish small defects is possible:
Responda
  • (a) Only with a very small source or focal spot size radiation source
  • (b) Routinely
  • (c) With most sources
  • (d) Never

Questão 17

Questão
17. A detrimental effect of fluorescent screens might be:
Responda
  • (a) High definition
  • (b) Screen mottle
  • (c) Non-linear attenuation
  • (d) Displaced core effect

Questão 18

Questão
18. The penetrating power of an X ray machine is indicated by:
Responda
  • (a) Milliamperage
  • (b) Tube voltage
  • (c) Filament current
  • (d) Anode current

Questão 19

Questão
19. Reticulation may be the result of:
Responda
  • (a) Inadequate agitation of the film during development
  • (b) Inadequate water rinse during processing
  • (c) Using exhausted stop bath solution
  • (d) Developing solutions not maintained at the same temperatures.

Questão 20

Questão
20. The main advantage of having small focal spot on an X ray tube is:
Responda
  • (a) Heat is conducted away more efficiently than with a large focal spot
  • (b) A smaller focal spot is unlikely to be damaged from the required tube currents
  • (c) Longer tube life
  • (d) A smaller focal spot allows sharper radiographic images than does a larger focal spot

Questão 21

Questão
21. Cobalt-60 is produced by:
Responda
  • (a) Fission of Uranium-235
  • (b) Neutron capture by Cobalt-59
  • (c) Radioactive decay
  • (d) None of the above

Questão 22

Questão
22. For a particular isotope, gamma radiation intensity is determined by:
Responda
  • (a) Type of isotope used
  • (b) Energy level of gamma rays in source
  • (c) Source strength in curies
  • (d) None of the above

Questão 23

Questão
23. Which of the following statements should be true to achieve the highest level of radiographic sharpness (definition)?
Responda
  • (a) The focal spot should be as small as practicable
  • (b) The focal spot to test piece distance should be as large as practicable
  • (c) The film to test piece distance should be as small as practicable
  • (d) All of the above

Questão 24

Questão
24. Which of the following correctly expresses the inverse square law if I1=dose rate nearest source, I2=dose rate furthest from the source, D1=distance nearest to source and D2=distance furthest from the source:
Responda
  • (a) I1/I2 = D1^2/D2^2
  • (b) I1^2/I2^2 = D1/D2
  • (c) I1/I2 = D2^2/D1^2
  • (d) I1^2/I2^2 = D2/D1

Questão 25

Questão
25. Thicker materials would normally be inspected using:
Responda
  • (a) Lower kV X rays
  • (b) Higher mA X rays
  • (c) Higher kV X rays
  • (d) Lower mA X rays

Questão 26

Questão
26. Another name for a penetrameter is:
Responda
  • (a) Radiographic shim
  • (b) Image quality indicator
  • (c) Density standard
  • (d) Acceptance standard

Questão 27

Questão
27. The silver nitrate spot test can be used to:
Responda
  • (a) Check the film for film quality
  • (b) Check for under developed films
  • (c) Check for film artifacts
  • (d) All the above answers are correct

Questão 28

Questão
28. The difference in densities seen on a radiograph due to section changes in an item is:
Responda
  • (a) Film contrast
  • (b) Radiographic contrast
  • (c) Subject contrast
  • (d) Radiographic sensitivity

Questão 29

Questão
29. Which type of film would exhibit the coarsest grain?
Responda
  • (a) Slow
  • (b) Medium
  • (c) Fast
  • (d) No difference in the grain sizes

Questão 30

Questão
30. An advantage of a gamma ray source is:
Responda
  • (a) Radiation may be turned on or off at will
  • (b) Outside power is normally not required
  • (c) Less shielding is required than for X ray
  • (d) All of the above

Questão 31

Questão
31. Higher X ray tube voltages result in:
Responda
  • (a) Shorter wavelengths X rays
  • (b) Less penetrating X rays
  • (c) Fewer X rays in the primary beam
  • (d) All of the above

Questão 32

Questão
32. A casting flaw which is formed when two masses of molten metal flowing from different directions flow together, but fail to fuse, is called:
Responda
  • (a) A hot tear
  • (b) Shrinkage
  • (c) A cold crack
  • (d) A cold shut

Questão 33

Questão
33. X rays are produced by:
Responda
  • (a) Radioactive isotopes
  • (b) The rapid deceleration of electrons
  • (c) Ultraviolet radiation of unstable atoms
  • (d) All of the above

Questão 34

Questão
34. Which of the following is a function of lead screens?
Responda
  • (a) To reduce geometric unsharpness
  • (b) To increase scatter
  • (c) To reduce exposure time
  • (d) All of the above

Questão 35

Questão
35. A silver nitrate spot test might be used to:
Responda
  • (a) Check for archival film quality
  • (b) Check for out of date film
  • (c) Check for single versus double emulsion film
  • (d) Any of the above

Questão 36

Questão
36. A linear accelerator is used to produce X rays having energy in the range of:
Responda
  • (a) Several MeV
  • (b) 50-500 keV
  • (c) 500-1000 keV
  • (d) 0-50 keV

Questão 37

Questão
37. How is the wavelength of scattered radiation compared to the primary beam?
Responda
  • (a) Longer than the wavelength of the primary beam
  • (b) Shorter than the wavelength of the primary beam
  • (c) Same as the wavelength of the primary beam
  • (d) Not related

Questão 38

Questão
38.Which of the following viewing conditions is most desirable for interpreting radiographic film?
Responda
  • (a) Brightness of surroundings approximately the same as the area of interest on the radiograph
  • (b) Totally dark viewing room
  • (c) Well lit viewing room
  • (d) None of the above

Questão 39

Questão
39. Pinhole radiography would be used to:
Responda
  • (a) Make high quality radiographs for critical inspection
  • (b) Determine focal spot size
  • (c) Construct exposure charts
  • (d) None of the above

Questão 40

Questão
40. A straight, dark line in the centre of the film of a weld cap would probably be:
Responda
  • (a) Porosity
  • (b) Undercut
  • (c) Tungsten inclusions
  • (d) A linear crack

Questão 41

Questão
41. Which one of the following steps is necessary to dissolve the undarkened silver salt crystals in the film emulsion:
Responda
  • (a) Developing
  • (b) Fixing
  • (c) Washing
  • (d) None of the above

Questão 42

Questão
42. Approximately what energy X ray machine would be required to have penetrating power equivalent to a Cobalt-60 source:
Responda
  • (a) 600 keV
  • (b) 1.2 MeV
  • (c) 2 MeV
  • (d) None of the above

Questão 43

Questão
43. The normal range of steel that is radiographed using Ir-192 is:
Responda
  • (a) 5 mm–20 mm
  • (b) 25mm–75mm
  • (c) 0.5mm–5mm
  • (d) 75mm–150mm

Questão 44

Questão
44. The focal spot size of an X ray machine must be known in order to determine:
Responda
  • (a) The geometric unsharpness
  • (b) Kilovoltage peak output
  • (c) Required mA setting
  • (d) Exposure time

Questão 45

Questão
45. X ray intensity is a function of :
Responda
  • (a) Cathode current
  • (b) Step down ratio of the filament transformer
  • (c) The distance from the test piece
  • (d) Size of the anode (target)

Questão 46

Questão
46. What is the minimum age in years at which a person may perform radiography :
Responda
  • (a) 15
  • (b) 18
  • (c) 21
  • (d) 30

Questão 47

Questão
47. A densitometer is an instrument that measures:
Responda
  • (a) Radiographic contrast
  • (b) Radiographic sensitivity
  • (c) Radiographic density
  • (d) Radiographic resolution

Questão 48

Questão
48. Which of the following is the correct formula to use for calculating geometric unsharpness if F=source size, T=specimen thickness, D=source to object distance and Ug=geometric unsharpness:
Responda
  • (a) Ug = FD/T
  • (b) Ug = DT/F
  • (c) Ug = FT/D
  • (d) Ug = FTD

Questão 49

Questão
49. A wetting agent is used in film processing to:
Responda
  • (a) More closely control development
  • (b) Prevent formation of water marks during the drying stage
  • (c) Reduce formation of air bubbles in the developer solution
  • (d) Reduce formation of air bubbles in the fixer

Questão 50

Questão
50. Film intensifying screens are normally used to:
Responda
  • (a) Decrease exposure time
  • (b) Increase grain size
  • (c) Shield film from stray light
  • (d) All of the above

Semelhante

Psicologia da Educação
rsgomes88
DIREITOS E DEVERES INDIVIDUAIS E COLETIVOS #1
Eduardo .
Genética Molecular: Ácidos Nucleicos
Renata Cavazzana
Macetes para Fórmulas de Física
Marina Faria
questões de homonimos e paronimos
mariana gasco
CONTABILIDADE DE CUSTOS (Samantha - Editar)
Samantha Iara Concolino
Geografia - Mapa do Brasil
GoConqr suporte .
Recursos hídricos
Homero Borba
Reading IELTS Vocabulary
Caio Uechi
Regra de Sinais
Adenilson Santana
Investigação científica
Claudina Quintino