Questão 1
Questão
During a master caution light recall the right pack light illuminates?
Responda
-
Indicating a failure of other the primary or standby pack control
-
Indication the right air conditioning pack is in high flow
-
Indicating the left pack has been selected off and right pack may overloaded
Questão 2
Questão
The off sched descent light illuminates if...?
Responda
-
The aircraft has climbed selected flight altitude
-
The aircraft has descended before reaching selected flight altitude
-
The aircraft climbed above the selected flight altitude
Questão 3
Questão
The maximum differential pressure for positive relief valve operation is
Questão 4
Questão
Right pack and zone controller consist of a?
Questão 5
Questão
İn case of clogging in water seperator in 737-700?
Responda
-
İndicator disc on the water seperator is in red range
-
Pack light amber illuminates
-
Duct overheat light amber illuminates
Questão 6
Questão
The purpose of the trim air pressure regulating valve is?
Responda
-
to provide fine adjustment of temperature of cabin zones
-
to regulate the hot air pressure 4 PSI more than the cabin pressure
-
to regulate the mass of air flow at the inlet packs
Questão 7
Questão
What are the conditions for e&e cooling fans operation?
Responda
-
The respective equipment cooling switch is in the supply/alternate position
-
The recirculation fan switch must be in the OFF position pack high flow
-
Both of pack switches must be off position the recirculation fan switch AUTO
Questão 8
Questão
In Boeing 737-600-700 aircrafts the right pack discharge overheat switch is located in?
Questão 9
Questão 10
Questão
The forward cargo compartment is warmed?
Responda
-
Only when the main outflow valve fully o..
-
At any time when more than 1 PSI difference pressure exist
-
In flight when more than 2,5 PSI difference
Questão 11
Questão
In auto pressurisation mode the cabin difference pressure for the off?
Responda
-
0,10 PSI
-
0,25 PSI
-
0,125 PSI
Questão 12
Questão
The pressurization system controls airplane with?
Responda
-
A control panel, two cabin pressure control and two outflow valves
-
A control panel two cabin pressure control and one outflow valves
-
A control panel one cabin pressure control and one outflow valve
Questão 13
Questão
Why does the DUAL BLEED light illuminate?
Responda
-
When the APU Bleed valve is closed and the Engine bleed switches On
-
When the APU Bleed valve is open and the Engine bleed switches On
-
When the APU Bleed valve is closed and Engine bleed switches Off
Questão 14
Questão
If an OFF SCHED DESCENT light comes on the pressurization system will
Responda
-
Pressure the cabin back to the take-off airport altitude
-
Return the cabin to the last cruise altitude
-
Reschedule pressurization rate of change
Questão 15
Questão
The FWD DOOR area heater is located in the ?
Responda
-
On the left outboard side of the nose wheel well
-
Right side of the FWD cargo compartment
-
On the right inboard side of the nose wheel well
Questão 16
Questão
The bleed air duct pressure indicator?
Responda
-
Requires AC power for operation
-
Operates only when the CDU operating
-
İndicates both temperature and pressure in the duct
Questão 17
Questão
When using the pneumatic air CENT the battery switch?
Responda
-
Must be on and air conditioning pack sw on
-
Must be on or off when using aircraft air conditioning
-
Must be on a d air conditioning pack switches off
Questão 18
Questão
Where is the receptacle for external compressed air?
Responda
-
Lower left side of the fuselage
-
Upper right side of the fuselage
-
Lower right side of the fuselage
Questão 19
Questão
The TRIP RESET switch on the -800-900 airconditioning panel will reset the?
Responda
-
BLEED TRIP OFF, DUCT OVERHEAT and ZONE TEMP lights provided the fault condition has been corrected.
-
DUCT OVERHEAT, PACK and ZONE TEMP lights provided the fault condition has been corrected
-
BLEED TRIP OFF, PACK, ZONE TEMP lights provided the fault condition has been corrected
Questão 20
Questão
What input required of the pilot for pressurization auto control system to function property?
Questão 21
Questão
After the overheat lights illuminated during OVERHEAT test?
Responda
-
Action is required as the resetting of the system on the window heat computer
-
No action is required as the resetting of system automatic
-
The window heat switches must be momentraily positioned to off to rest the system
Questão 22
Questão
When one air conditioning pack switch selected to HIGH?
Responda
-
Related pack will regulate to LOW FLOW with flap extend
-
Flap selection has no effect on the low flow rate of that pack
-
The operating pack will regulate to high flow only with flaps up
Questão 23
Questão
If the external pressure exceeds the internal pressure the ... will open?
Questão 24
Questão
The CONT CAB amber ZONE TEMP light illuminate with recall indicates?
Responda
-
Primary or Standby pac controller failure
-
Primary pack controller failure
-
Primary and stanby pack controller failure
Questão 25
Questão
The APU will switch into a HIGH FLOW rate then?
Questão 26
Questão
When the Rİght Pack switch OFF and the isolation valve switch is in AUTO, the isolation valve will?
Questão 27
Questão
The RH Pack/Zone Temperature controller?
Responda
-
Controls the flight deck and provides back up control for the aft cabin
-
Controls the flight deck and fwd cabin
-
Controls the fwd cabin and provides backup control for the flight deck
Questão 28
Questão
Burnination of the amber Bleed Trip Off light indicates ... has automatically closed?
Questão 29
Questão
The lh pack zone temperature controller?
Responda
-
Controls the FWD cabin and provides backup control for the aft cabin
-
Controls the FWD cabin and provides backup control for the flight deck
-
Controls the AFT cabin and provides back up control for the flight deck
Questão 30
Questão
Trim Air Modulating Valves are controlled by?
Responda
-
The pressure controllers for the fine adjustment of temperature
-
The pack controllers for the basic temperature regulation
-
Two pack zone controllers for thefine adjustment of temperature
Questão 31
Questão
With one air conditioning pack sitch selected to high?
Responda
-
The pack will regulate to LOW FLOW with flap extended
-
Flap sekection has ne effect on the flow rate of that pack
-
The operating pack will reguate o HIGH FLOW only with glaps up
Questão 32
Questão
In 737-700 series aircraft the air mix valve?
Questão 33
Questão
When the PACK TRIP OFF (amber) light illuminates in 737-700 aircraft?
Responda
-
THe hot butterfly of airmix valve opens automatically
-
Flow control and shut off valve closes automatically
-
Low limit valve closes automatically
Questão 34
Questão
In 737-600/700 rh pack discharge overheat switch is located in
Questão 35
Questão
If the AMBER AUTO FAIL light illuminates on the pressurization panel?
Responda
-
Positioning the Pressure Mode Selector to alternate will extinguish the AUTO FAIL light
-
It will automatically extinguis when the pressurization controllers reverts the alternate mode
-
Positioning the Pressurization mode selector to alternate will have no effect on the AUTO FAIL light
Questão 36
Questão
The OUT FLOW valve has ?
Responda
-
Two motores each controlled by a decide cabin pressure controllers
-
Three motors controlled by a CPC
-
Three motors, two automatically one manually controlled
Questão 37
Questão
Which of the following overheat switches or overtemperature sensors detect and overheat condition when a pack light illuminates?
Responda
-
Compressor discharge overheat switch,ü turbin inlet overheat switch 190F/88c duct overheat switch or duct limit sensor
-
Compressor discharge overheat switch, turbine inlet overheat switch 190f/88c duct overheat switch
-
Compressor discharge overheat switch, turbine inlet overheat switch or pack discharge overheat switch
Questão 38
Questão
The PITOT PROBE HEATERS lights are?
Responda
-
Amber in color and associated with the system
-
Not associated with the Master Caution
-
Illuminated when heat is being supplied pitot static and probe heaters
Questão 39
Questão
The High Stage Modulating and Shut Off valve?
Responda
-
Is opened at all times irrespective of 5th stage air pressure output
-
Will open if the 5th stage air pressure is insufficent
-
will open if the APU bleed air pressure is insufficient
Questão 40
Questão
Standby temperature control valve is ?
Responda
-
Fully controlled PACK/ZONE controller
-
Electrically controlled and operated
-
Either electrically controlled or pneumatically controlled
Questão 41
Questão
Where is the flight compartment 190F/88c duct overheat switch located? (600-700)
Questão 42
Questão
The cowl ANTI-ICE light is?
Responda
-
Amber in clour indicating over temp or over pressure
-
Blue colur and when illuminated indicates the engine cowl anti-ice valve is in disagreement with the engine anti-ice switch
-
Amber in colour indicating overpressure only
Questão 43
Questão
For 800/900 what controls the operating of the temperature control system
Responda
-
The cabin temperature controller only
-
The temperature controller panel and air conditioning bleed air control panel
-
The temperature control panel , the ACAU and PACK/ZONE Temperature Controller
Questão 44
Questão
The maximum external air pressure (ground cart)
Responda
-
30 PSI (at 231C)
-
40 PSI (at 231C)
-
60 PSI (at 231C)
Questão 45
Questão
A pack Lİght illuminates in flight (without recall)
Responda
-
The standby pack has failed but the primary control is operational
-
The primary pack has failed but the standby control is operational
-
Both primary and standby pack controls have failed.
Questão 46
Questão
An engine Bleed Trip OFF light will illuminate
Responda
-
When engine bleed air temperature or pressure exceeds a predetermined limit
-
Only if engine bleed air pressure exceeds a predetermined limit
-
Only if engine bleed air temperature exceeds a predetermined limit
Questão 47
Questão
The wing Anti-ice control valve_
Questão 48
Questão
With ISOLATION VALVE switch AUTO both ENG BLEED sw ON and BOTH Air Cond Pack sw selected AUTO or HIGH?
Responda
-
The ISOLATION VAlVE will be closed
-
The ISOLATION VAlVE will be opened
-
The ISOLATION VAlVE will be closed when the flaps are extend
Questão 49
Questão
If the ACM compressor discharge overheat switch activated this?
Responda
-
Commands the RAM AIR system full close
-
Close the PACK FLOW CONT SOV and PACK light on
-
Causes the pack to go to a HIGH FLOW mode of operation
Questão 50
Questão
THe total air temperature probe
Questão 51
Questão
When the pack discharge reaches 250f/121c (overheat) to reset the Air Conditioner sys?
Questão 52
Questão
When you use the wing theamal anti-icing system on the ground?
Responda
-
De-icing fluids are not necessary
-
There is no protection to prevent heating leading edge overheat conditions
-
THe WTAI selenoid bleeds control pressure from the Precooler Control Valve
Questão 53
Questão
Which is feed into WTAI?
Pneumatic system
Questão 54
Questão
Pack'lerin AUTO dan HİGH a geçmesi için?
Flaps up
Questão 55
Questão
Duct temp 88C ?
Zone TEMP
Questão 56
Questão
PRSOV closes when?
Pressure is 220 PSI
Questão 57
Questão
Ground cart supply pressure?
60 PSI
Questão 58
Questão
Isolation valve operate?
AC
Questão 59
Questão
Compressor 9th stage?
High pressure
Questão 60
Questão
E/E ventilation?
Equipment ventilation (cooling)
Questão 61
Questão
Wiper how does operate?
With knob rotary
Questão 62
Questão
Cabin altitude aural warning when?
10.000 feet
Questão 63
Questão
Air comes to precooler where?
Fan
Questão 64
Questão
ANTI-ICE Heater test?
HEATER sw ON
Questão 65
Questão
Pack switch positions?
OFF-AUTO-HIGH
Questão 66
Questão
Outflow valve manual controls?
OPEN-CLOSE
Questão 67
Questão
Positive pressure relief valve?
8,95 PSI
Questão 68
Questão
What is the PACKs purposes?
Basic temperature
Questão 69
Questão 70
Questão
Window heater?
Interchangable
Questão 71
Questão
OFF SCHED DESCENT LIGHT?
Take off airport altitude
Questão 72
Questão
PITOT heats?
115v ac
Questão 73
Questão
RAM AIR actuator?
115v ac
Questão 74
Questão
Wing thermal Anti Ice?
Thrust levers more than 60 degree system doesnt operate. Wing Anti Ice ground thermal on switch iki kanat valflerini de kapatır.
Questão 75
Questão
9th stage 110 PSI ?
High stage fully close
Questão 76
Questão
490 F (254 C) ?
PRSOV close
Questão 77
Questão
Flow control and Shut off valve ?
Selenoid A= APU/HIGH flow operation
Selenoid B= LOW and HIGH flow
Selenoid C= Open close valve
Questão 78
Questão
Isolation valve position?
Auto-Close
Questão 79
Questão
Cocpit air?
LH PACK
Questão 80
Questão
TAI ?
Shows N! indicator- Green
Questão 81
Questão
Duct pressure indicator?
P5 panel
Questão 82
Questão 83
Questão
Positive relief valve?
Pneumatic
Questão 84
Questão
Recirculation fan?
115v 3 phase
Questão 85
Questão
Duct temp 88 üstü?
ZONE TEMP light
Questão 86
Questão
LOW LIMIT sensor?
Equipment cooling supply and exhaust
Questão 87
Questão
Packler AUTO da bir Pack HIGH a geçmesi için?
Flaps up
Questão 88
Questão
737-600-700 duct temp 88 C?
DUCT OVHT light
Questão 89
Questão
737-800/900 DUCT TEMP 88C ?
ZONE TEMP light
Questão 90
Questão
Compressor çıkış sıcaklığı 199 C?
Pack light yanar
Questão 91
Questão
PRSOV ne zaman kapalıya gider?
Basınç 220 PSI
Questão 92
Questão
TAI amber light N1?
Valve position not agree more than 8 second
Questão 93
Questão
Cowl Anti-Ice amber light?
Overpressure only
Questão 94
Questão
Cabin altitude pressure switch?
Cabin altitude reached 10000
Questão 95
Questão
Precooler sensor nerede?
ENG Strut Duct
Questão 96
Questão
Ground thermal WTAI Sensor?
Downstream of WTAI
Questão 97
Questão
Door heating system?
-Any pack on
-Arcraft on air
Questão 98
Questão
Heat exchanger blokage?
RAM DOOR FULL OPEN blue light on
Questão 99
Questão
Duct pressure transmitter?
Air cond bay
Questão 100
Questão
Flight Compartment?
LH PACK
Questão 101
Questão
During ENG start?
PRSOV close
Questão 102
Questão
Cargo blowout panels?
1 PSI differenatial pressure
Questão 103
Questão
TRIP RESET?
-ZONE TEMP
-BLEED TRIP OFF
-PACK
Questão 104
Questão
Overheat Switches?
-comp. discharge
-turbine inlet switch
-pack discharge
Questão 105
Questão
Trim Air Regulating Shut Off valve?
+4 PSI Cabin air
Questão 106
Questão
Recirculation system?
Fuel save
Questão 107
Questão
Recirculation fans?
Ground= LH Recirc. FAN BOTH PACK HIGH FLOW iken çalışmaz diğer tüm şartlarda yerde çalışır.
RH Recirc. FAN yerde her zaman çalışır
Air= LH Recirc. FAN herhangi PACK HIGH da ise çalışmaz
RH Recirc. FAN iki PACK HIGH ise çalışmaz
Questão 108
Questão
-600/700 Aircodition?
1 CTC
1 ACAU
1 CONTROL PANEL
Questão 109
Questão
RH PACK ZONE CONTROLLER?
-Flight compartment
-FWD pass. cabin
Questão 110
Questão
NGS Shut Off valve?
Center Tank Re-Fuel Valve closed