ST Monitoring Quiz

Descrição

ST monitoring via Philips monitor
Natalie Tredway
Quiz por Natalie Tredway, atualizado more than 1 year ago
Natalie Tredway
Criado por Natalie Tredway mais de 9 anos atrás
278
1

Resumo de Recurso

Questão 1

Questão
ST analysis can be performed on the patient with 1:1 ventricular pacing.
Responda
  • True
  • False

Questão 2

Questão
The ST segment is:
Responda
  • Normally elevated in all leads
  • Normally isoelectric in all leads
  • Normally depressed in all leads
  • Damaged and ischemia causes the cells of the myocardium to become more or less excitable.

Questão 3

Questão
ST segment measurements are displayed and trended in:
Responda
  • mmHg
  • mm
  • kpal

Questão 4

Questão
The ST Leads that are being monitored depend on: (choose all that apply)
Responda
  • The leads available based on the lead set used and electrodes applied.
  • The Lead Placement selected - Standard or EASI
  • The number of leads displayed on the Main Screen.
  • The leads setup for monitoring.

Questão 5

Questão
When ST Analysis is turned off:
Responda
  • No ST analysis or arrhythmia analysis is performed.
  • No ST analysis is performed but arrhythmia analysis continues.

Questão 6

Questão
To turn off individual leads of ST:
Responda
  • Change to another screen
  • In the ST Analysis menu, select Setup ST Leads.
  • In the ECG menu, select New Lead Setup.
  • In the ST Analysis menu, select, select ST Analysis.

Questão 7

Questão
Selecting Alarms in the ST Analysis menu:
Responda
  • Turns on/off all ST alarms.
  • Allows you turn off individual ST alarms.
  • Silences ST alarms for 5 minutes.
  • Allows you to select single-lead or multi-lead alarms.

Questão 8

Questão
Multi-lead alarms will cause an alarm only when:
Responda
  • All monitored ST leads exceed the limits set for 15 seconds.
  • Three or more leads exceed the limits set for 15 seconds.
  • Two or more leads exceed the limits set for 1 minute.
  • Three or more leads exceed the limits set for 1 minute.

Questão 9

Questão
ST alarms set using Auto Limits Wide: (choose all that apply)
Responda
  • Changes the alarm limits based on the last 5 minutes of data.
  • Change as the patient’s condition changes
  • Changes the alarm limits based on the last 1 minute of data.
  • Will not change until you change them manually or use AutoLimits again.
  • Will not set alarm limits in pathological range.

Semelhante

Analgesicos
Adriana
Phrasal Verbs - Inglês #3
Eduardo .
10 Dicas de Como Estudar Online
GoConqr suporte .
Introdução ao Microsoft Word
Roberto Becker
Português para Vestibular
GoConqr suporte .
Practice For First Certificate Grammar I_1
beatriz costa
Redação para Vestibular
Alice Sousa
Anatomia: sistema esquelético I
Natália Abitbol
Resumo para o exame nacional - Fernando Pessoa Ortónimo, Alberto Caeiro , Ricardo Reis e Álvaro Campos
marisacampos.ave
A Era Vargas (1930-45)
Alice Sousa
Hebreus, Fenícios e Persas
Júlia Flores