Questão 1
Questão
What is the recommended power range for microscopes to view the end face of an optical fiber connector
Responda
-
100x-200x
-
100x-800x
-
200x-400x
Questão 2
Questão
_____ cabling provides interconnection between TRs, ERs, main terminal space & EF (entrance facilities)
Responda
-
backbone
-
horizontal
-
riser
Questão 3
Questão
To confine the light within the core by creating a reflective boundary is the purpose of the _______
Questão 4
Questão
This space is a special purpose room that provides and maintains a suitable operating environment for large telecommunications equipment
Questão 5
Questão
During a retrofit, it is not required to remove all abandoned cable
Questão 6
Questão
This space should not serve more than 3,600 sq/ft
Questão 7
Questão
What is the most common specialty fastener used in ITS cabling
Responda
-
j-hook
-
toggle bolt
-
drive ring
-
bridal ring
Questão 8
Questão
Interbuilding circuits are considered to have lightning exposure unless 1 or more conditions exist (select all correct)
Responda
-
Buildings close together and sufficiently high
-
Cable run is 140ft or less (underground or in conduit)
-
Area having an avg. of 5 or fewer t-storms per year and earth resistivity less than 100 ohms
Questão 9
Questão
This tester uses Rayleigh scattering & Fresnal reflection to measure the characteristics of an optical fiber
Questão 10
Questão
The ITS installer is allowed to add more firestopping product to get a higher rating
Questão 11
Questão
Cross-Connect Field Colors: Future (Key Telephone Systems)
Questão 12
Questão
What is used to flush electrolyte burns to the skin
Responda
-
water
-
milk
-
sodium bicarbonate
Questão 13
Questão
Shorter wavelengths of light exhibit greater amounts of attenuation because of Rayleigh scattering
Questão 14
Questão
Longer wavelengths are more sensitive to bending loss and will allow light to exit out of the fiber core more than shorter wavelengths
Questão 15
Questão
What is the minimum separation of telecommunications cabling and electric motors & transformers
Responda
-
12 inches
-
36 inches
-
48 inches
-
60 inches
Questão 16
Questão
This firestop material has the ability to absorb heat to prevent the temperature from rising on the other side of the fire barrier
Responda
-
endothermic
-
ablative
-
intumescent
Questão 17
Questão
Where does the SCS begin
Responda
-
where the SP terminates
-
ER
-
TR
Questão 18
Questão
What is the signal range for POTS
Responda
-
300Hz-3400Hz
-
300MHz-3400MHz
-
20Hz-20,000Hz
Questão 19
Questão
This type of protector has a reaction time of 1-2 ns
Responda
-
fire & data
-
carbon
-
gas
-
solid state
Questão 20
Questão
Cross-Connect Field Colors: Interbuilding Backbone
Questão 21
Questão
The frequency of CAT5e is
Responda
-
100MHz
-
250MHz
-
500MHz
-
150MHz
Questão 22
Questão
The frequency of CAT3 is
Questão 23
Questão
The frequency of CAT6a is
Responda
-
100MHz
-
250MHz
-
350MHz
-
500MHz
Questão 24
Questão
The frequency of CAT6 is
Responda
-
100MHz
-
250MHz
-
350MHz
-
500MHz
Questão 25
Questão
How many pairs are in a super group
Questão 26
Questão
How many binder groups are in each super group
Questão 27
Questão
What are the 2 common methods of terminating balanced twisted pair cable (select all correct)
Questão 28
Questão
Which of the following cables meet the minimum requirements for cabling to a work area (select all correct)
Responda
-
4 pair, 100 Ohm CAT5e cable
-
4 pair, 100 Ohm CAT6 cable
-
2 or more strands of 62.5 or 50 (OM1 or OM2)
-
2 or more strands of singlemode
Questão 29
Questão
Why is undercarpet cable not recommended (select all correct)
Questão 30
Questão
The interconnection between undercarpet cable and horizontal cable is called what
Responda
-
TP (transition point)
-
CP (consolidation point)
-
MUTOA
Questão 31
Questão
If using undercarpet cable, what is recommended maximum length of the cable
Questão 32
Questão
What are the most common connectors for multimode fiber (select all correct)
Questão 33
Questão
What are the common modular connectors used in ITS (select all correct)
Questão 34
Questão
What are the most predominant coaxial cables (select all correct)
Responda
-
Series 6
-
Series 59
-
Series 11
-
RG6
-
RG58
-
RG59
Questão 35
Questão
The F connector is the most commonly used connector for residential cable service
Questão 36
Questão
What are the common BNC connector types (select all correct)
Responda
-
3 piece crimp
-
1 piece compression
-
screw-on
Questão 37
Questão
What is the maximum pulling tension of 4-pair, balanced twisted pair cabling
Responda
-
25 pounds-force (lbf)
-
20 pounds-force (lbf)
-
30 pounds-force (lbf)
Questão 38
Questão
What is the minimum bend radius of 4 pair cable
Responda
-
4 times cable diameter
-
5 times cable diameter
-
4 inches
-
5 inches
Questão 39
Questão
What is the recommended service slack for 4-pair cables at the work area
Responda
-
12 inches
-
24 inches
-
36 inches
Questão 40
Questão
What is the recommended service slack for a 4 pair cable in the TR/ER
Questão 41
Questão
What is the recommended service slack for multipair cable in a TR/ER
Questão 42
Questão
What is the recommended service slack for 4 pair & multipair cable at a TE
Questão 43
Questão
The tensile strength of pull string is typically
Responda
-
75-200 lbf
-
100-200 lbf
-
50-100 lbf
-
75-150 lbf
Questão 44
Questão
A pull string should be attached to cable with what type of knot and how many knots
Responda
-
3 half hitches
-
2 half hitches
-
3 square knots
-
2 square knots
Questão 45
Questão
Structural steel members (red iron) can be used to support cables if they are spaced 4-5ft
Questão 46
Questão
What are the common splice connectors for copper (select all correct)
Responda
-
straight through
-
butt splice
-
half tap
Questão 47
Questão
What are the common splice enclosures (select all correct)
Questão 48
Questão
Which copper splicing method allows the conductors to be folded into the splice and allows for maintenance, rearrangement and transfer of the conductors
Responda
-
Inline
-
Foldback
-
Butt
-
Branch
Questão 49
Questão
What is the minimum bend radius of a 4 pair balanced twisted pair cord
Responda
-
1x patch cord diameter
-
4x patch cord diameter
-
4 inches
-
2 inches
Questão 50
Questão
What is the minimum bend radius of a multipair cable
Questão 51
Questão
Cable pair twists for CAT3 must be maintained to within ____________ of termination
Responda
-
3 inches
-
2 inches
-
1 inch
-
.5 inches
Questão 52
Questão
Cable pair twists for CAT5e or higher must be maintained to within ____________ of termination
Responda
-
.5 inches
-
.25 inches
-
.75 inches
-
1 inch
Questão 53
Questão
110 blocks come in increments of ________ pairs (select all correct)
Questão 54
Questão
BIX blocks come in increments of ________ pairs (select all correct)
Questão 55
Questão
Field terminated patch cables are not recommended for CAT5e
Questão 56
Questão
What is the most common video connector in the industry
Questão 57
Questão
Specification and visual inspection is what phase of testing
Questão 58
Questão
Testing with various test equipment is what phase of testing
Questão 59
Questão
Documentation is what phase of testing
Questão 60
Questão
Except in particular cases, what is the maximum length of equipment cords
Questão 61
Questão
A consolidation point will extend the horizontal cabling length
Questão 62
Questão
What is the maximum amount of work areas that a MUTOA should serve
Questão 63
Questão
A minimum of 1 dedicated, non-switched duplex receptacle should be available for equipment in each _________
Questão 64
Questão
What is the maximum square footage a TE should serve
Questão 65
Questão
What is minimum recommended cable tray width for an ER, TR or EF
Responda
-
12 inches
-
18 inches
-
6 inches
-
24 inches
Questão 66
Questão
Which grade of plywood has knotholes without any repair
Responda
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Questão 67
Questão
Which grade of plywood contains some blemishes and the occasional knothole
Responda
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Questão 68
Questão
Which grade of plywood has the knotholes cut out and replaced with a patch of clean wood
Responda
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Questão 69
Questão
Which grade of plywood is the highest grade and is without any surface blemishes
Responda
-
Grade A
-
Grade B
-
Grade C
-
Grade D
Questão 70
Questão
Which grade of plywood should be used for ER, TR & EFs
Questão 71
Questão
How many walls should have plywood installed
Questão 72
Questão
Select all that apply to backboards in ERs, TRs & EFs
Responda
-
3/4" thick plywood
-
at least 2 coats of fire retardant paint
-
minimum 1/4" toggle bolts
-
toggle bolts should be spaced 24 inches
-
toggle bolts should be 2 inches from the edge of the plywood
-
plywood should be mounted 6 inches AFF
Questão 73
Questão
Most ITS installations will require a 19 inch by 7 ft rack
Questão 74
Questão
What are the common depths of racks (select all correct)
Questão 75
Questão
What are the popular thread sizes for racks/cabinets (select all correct)
Questão 76
Questão
What is the preferred size of patch panels
Questão 77
Questão
What are the reasons that FMT is not recommended (select all correct)
Responda
-
creep
-
shift
-
damage cable sheath
Questão 78
Questão
If using FMT, what rules must be followed (select all correct)
Questão 79
Questão
How many 90 degree bends are allowed in conduit segment
Questão 80
Questão
If more than two 90 degree bends are needed, what must be done (select all correct)
Responda
-
run is not longer than 33ft
-
increase conduit 1 trade size
-
install one 90 degree bend within 12 inches of feed end
Questão 81
Questão
When conduits enter a TR through the floor, how far should they protrude
Responda
-
6 inches
-
2-4 inches
-
1-3 inches
Questão 82
Questão
What are the 3 common depths of basket tray (rod stock tray) (select all correct)
Questão 83
Questão
This is the portion of the data center that actually houses the IT equipment
Responda
-
Computer Room
-
Equipment Room
-
Entrance Room
Questão 84
Questão
Which types of cables are recognized in data center telecommunications (select all correct)
Questão 85
Questão
Which two types of coaxial cable does ANSI/TIA 942 recognize for E1, E3 & T3 circuits (select all correct)
Responda
-
734-type
-
735-type
-
Series 6
-
Series 11
Questão 86
Questão
Which type of connectors are installed on 734-type and 735-type coaxial cable for E1, E3 & T3 circuits (select all correct)
Questão 87
Questão
Cable trays in data centers should be planned for initial maximum calculated fill ratio of ________%
Questão 88
Questão
How much clearance should be provided above the of cable trays when they are installed above cabinets
Responda
-
12 inches
-
10 inches
-
6 inches
-
18 inches
Questão 89
Questão
How much clearance should be above a cable tray that is installed below a raised floor
Responda
-
2 inches
-
3 inches
-
6 inches
-
12 inches
Questão 90
Questão
Cable trays installed under raised floors in data centers should be installed in the cold aisle
Questão 91
Questão
In a data center, how much horizontal cable management should be provided for each 1u of patch panel
Questão 92
Questão
Power strips supporting only single-corded equipment should be loaded no more than _______% of circuit capacity
Questão 93
Questão
Power strips supporting only dual-corded equipment should be loaded no more than _______% of circuit capacity
Questão 94
Questão
Some unique aspects of health care regarding access control are (select all correct)
Responda
-
elevator controls (cab calls and override)
-
integration will infant protection, wandering patient and elopement systems
-
card readers not always being located at the door
-
multiple levels of access control for care providers, visitors and security
Questão 95
Questão
In a health care facility, PT (pneumatic tube) system is typically what size tubing
Questão 96
Questão
Central equipment cabinets are the heart of the system and likely will occupy 4ft x 8ft of wall space in the TR
Questão 97
Questão
HEPA/ultra-low penetration air (ULPA) vacuum cleaners shall trap _________% of particles 0.12 micrometers and larger
Questão 98
Questão
In health care facility projects, the safety officer or facilities director shall make at least _________ documented visit(s) per week to each construction work zone
Questão 99
Questão
This document is the understanding between the customer and the contractor
Responda
-
project contract
-
scope of work
-
specifications
Questão 100
Questão
CLA Series System Drawings: Campus or Site Plans
Questão 101
Questão
CLA Series System Drawings: Layout of complete building per floor
Questão 102
Questão
CLA Series System Drawings: Serving Zones: drop locations and cable IDs
Questão 103
Questão
CLA Series System Drawings: Communication equipment rooms
Questão 104
Questão
CLA Series System Drawings: Typical detail drawings: face-plate labeling, firestopping
Questão 105
Questão
CLA Series System Drawings: Schedules
Questão 106
Questão
What are the 3 major areas in security that may be part of an ITS installer's work (select 3)
Questão 107
Questão
A fire alarm system should be designed by a licensed fire protection engineer to ensure proper coverage and code compliance
Questão 108
Questão
DAS consists of an infrastructure of electronic devices including (select all correct)
Responda
-
amplifiers
-
cabling
-
connectors
-
antennas
-
hardware
Questão 109
Questão
This is a device that transmits and receives electromagnetic waves
Responda
-
antenna
-
transmitter
-
transceiver
Questão 110
Questão
Each 6dB increase in an antenna equals the ___________ of the possible range
Questão 111
Questão
Each 6dB decrease in an antenna equals the ___________ of the possible antenna range
Questão 112
Questão
The standoffs for a radiating cable need to be _______ inches below the cable tray
Responda
-
2 inches
-
3 inches
-
4 inches
-
6 inches
Questão 113
Questão
Wireless access points should be mounted at least ________ meter(s) from any metal obstructions
Questão 114
Questão
Most antennas used with APs indoors come with a ______ cable, commonly known as a pigtail
Questão 115
Questão
What are the 3 common voltages used in centrally amplified systems (select 3)
Questão 116
Questão
Which paging system operates at 24vdc
Questão 117
Questão
Which paging system will typically have 2 conductor cable installed
Responda
-
centrally amplified
-
distributed amplified
Questão 118
Questão
What are the 2 common types of sound masking systems (select 2)
Responda
-
in-plenum
-
direct-field
-
above ceiling
Questão 119
Questão
What time each day does the master clock send a longer pulse that corrects all of the secondary clocks to the correct hour
Questão 120
Questão
D-loading coils are commonly placed by telephone companies at which distance
Questão 121
Questão
H-loading coils are most commonly placed by the telephone company at which distance
Questão 122
Questão
Loss for premise cabling, including taps, should not exceed _____ dB of loss