Questão 1
Questão
Which of the following is a FALSE statement?
Responda
-
Rotating anode tubes are a complete vacuum, whereas earlier Crooke's tubes were a partial vacuum
-
Rotating anode tubes are stationary
-
Despite the focal spot size remaining constant, rotating anode tubes increase the area of the anode exposed to the beam
Questão 2
Questão
FID stands for [blank_start]Focalspot[blank_end] to [blank_start]Image[blank_end] [blank_start]Distance[blank_end]
Responda
-
focal spot
-
Image
-
Distance
Questão 3
Questão
FOD stands for [blank_start]Focal spot[blank_end] to [blank_start]Object[blank_end] [blank_start]Distance[blank_end]
Responda
-
Focal spot
-
Object
-
Distance
Questão 4
Questão
OID stands for [blank_start]Object[blank_end] to [blank_start]Image[blank_end] [blank_start]Distance[blank_end]
Questão 5
Questão
What is this formula used for?
Responda
-
Magnification Factor
-
Maximum mAs setting
-
Collimation threshold
Questão 6
Questão
Label the anatomical parts of the body.
Responda
-
Cranial
-
Inferior
-
Caudal
-
Distal
-
Proximal
-
Left
-
Right
-
Anterior
-
Posterior
-
Superior
-
Medial
-
Lateral
Questão 7
Questão
Label the anatomical planes.
Responda
-
Sagittal
-
Transverse
-
Coronal
Questão 8
Questão
Fill in the following body positions:
[blank_start]erect[blank_end] standing or sitting
[blank_start]decubitus[blank_end] lying down
[blank_start]supine[blank_end] lying on back
[blank_start]prone[blank_end] lying facedown
[blank_start]lateral decubitus[blank_end] lying on one side
[blank_start]right lateral[blank_end] right side touches the image plate
[blank_start]left lateral[blank_end] left side touches the image plate
Responda
-
erect
-
decubitus
-
supine
-
prone
-
lateral decubitus
-
right lateral
-
left lateral
Questão 9
Questão
Label the parts of the x-ray tube.
Responda
-
Anode
-
Cathode
-
Window
-
Anode target
-
Rotor
-
Evacuated glass envelope
-
Housing
-
Stator coils
Questão 10
Questão
Fill in the blanks with the appropriate terms:
The [blank_start]anode[blank_end] disc has a target track made of 90% [blank_start]tungsten[blank_end] and 10% [blank_start]rhenium[blank_end]. Tungsten has a high [blank_start]melting point[blank_end] and high atomic number giving it a high [blank_start]thermal capacity[blank_end]. The addition of rhenium produces less [blank_start]roughening[blank_end].
The anode disk base is made of a [blank_start]molybdenum graphite alloy[blank_end] making it [blank_start]lightweight[blank_end] with [blank_start]good heat dissipation[blank_end].
The rotor is made of [blank_start]copper and iron[blank_end] giving it a high thermal capacity and [blank_start]conductivity[blank_end].
Questão 11
Questão
X-rays are produced by [blank_start]high voltage[blank_end] acceleration of electrons from a [blank_start]tungsten filament[blank_end] [blank_start]negative cathode[blank_end] (3) within a [blank_start]vacuum[blank_end], towards a [blank_start]tungsten target[blank_end] on a [blank_start]positive anode[blank_end] (4). This anode [blank_start]rotates[blank_end] to dissipate heat generated. [blank_start]Photons[blank_end] are generated through [blank_start]atom interaction[blank_end] in the anode and an [blank_start]x-ray beam[blank_end] (5) is directed towards the [blank_start]patient[blank_end].
Responda
-
high voltage
-
tungsten filament
-
negative cathode
-
vacuum
-
tungsten target
-
positive anode
-
rotates
-
Photons
-
atom interaction
-
x-ray beam
-
patient
Questão 12
Questão
[blank_start]Bremsstrahlung[blank_end] x-rays occur when an [blank_start]electron[blank_end] passes very near the [blank_start]nucleus[blank_end] of an atom and is slowed and deviated from the resulting [blank_start]electromagnetic interaction[blank_end]. In this process, the electron loses [blank_start]energy[blank_end] and a [blank_start]photon[blank_end] (x-ray) is emitted.
Questão 13
Questão
A [blank_start]characteristic[blank_end] x-ray is when a [blank_start]high energy[blank_end] electron (1) collides with an [blank_start]inner shell[blank_end] electron (2) in a tungsten [blank_start]atom[blank_end]. Both are ejected from the atom leaving a [blank_start]vacancy[blank_end] in the inner shell. This is filled by an [blank_start]outer shell[blank_end] electron (3) with a loss of energy emitted as an [blank_start]x-ray photon[blank_end] (4).
Responda
-
characteristic
-
high energy
-
inner shell
-
atom
-
vacancy
-
outer shell
-
x-ray photon
Questão 14
Questão
Ionising radiation is radiation that has enough enery to free an electron from an atom, creating an ion.
Questão 15
Questão
Match the keyword with the correct definition:
[blank_start]kVp[blank_end] measure of the maximum voltage potential across an x-ray tube, responsible for acceleration of the electrons from the cathode to the anode
[blank_start]mA[blank_end] determines current through filament, a measure of the total number of electrons flowing from cathode to anode
[blank_start]time[blank_end] controls duration of electron flow being subjected to the voltage differential, determines duration of bombardment of anode by electrons
[blank_start]mAs[blank_end] product of exposure time and x-ray tube current, becomes the Total Radiation Output
Responda
-
kVp
-
mA
-
mAs
-
time
-
mA
-
kVp
-
mAs
-
time
-
time
-
mA
-
mAs
-
kVp
-
mAs
-
mA
-
time
-
kVp
Questão 16
Questão
What is meant by the term resolution in medical imaging?
Responda
-
The ability to image two different objects and visually distinguish them from one another
-
The scale of contrast on an image
-
The product of kVp and mAs
Questão 17
Questão
A lower spatial frequency (line pairs per millimetre) indicates better spatial resolution.
Questão 18
Questão
When an image is produced with [blank_start]few[blank_end] x-rays (i.e. [blank_start]low mAs[blank_end]) the quantum mottle will be [blank_start]higher[blank_end] than if the image was produced with [blank_start]many[blank_end] x-rays (i.e. [blank_start]high mAs[blank_end]).
Responda
-
few
-
many
-
low mAs
-
high mAs
-
higher
-
lower
-
many
-
few
-
high mAs
-
low mAs
Questão 19
Questão
The following can all be used to reduce scatter radiation: collimation, compression band, grid, air gap technique.