Question 1
Question
in a modern gas furnace, the component that separates the combustion gases from the supply air is the __________.
Answer
-
gas valve
-
heat exchanger
-
inducer fan
-
plenum box
Question 2
Question
what type of furnace moves warm air through the conditioned space without a fan?
Answer
-
gravity
-
horizontal
-
lowboy
-
upflow
Question 3
Question
furnace heat exchangers generally are made of ___________.
Answer
-
ceramic
-
copper
-
plastic
-
steel
Question 4
Question
what does AFUE stand for?
Answer
-
actual fuel usage efficiency
-
annual fuel utilization efficiency
-
annual furnace usage equivalency
-
approved fuel usage estimate
Question 5
Question
the main purpose of a secondary heat exchanger is to _________.
Answer
-
evaporate the flue gases
-
provide a backup containment
-
remove additional heat from the flue gases
-
reverse the primary air flow
Question 6
Question
which gas commonly used as a fuel in gas furnaces is heavier than air?
Answer
-
butane
-
isobutene
-
methane
-
propane
Question 7
Question
which grade of fuel oil is commonly used in residential furnaces
Question 8
Question
how many cubic feet of air are needed to burn 1 ft3 of natural gas
Question 9
Question
how many cubic feet of air are needed to burn 1 ft3 of propane
Question 10
Question
what is the approximate heat content of 1 ft3 of natural gas?
Answer
-
500 btu
-
800 btu
-
1050 btu
-
2500 btu
Question 11
Question
what is the approximate heat content of 1 ft3 of propane
Answer
-
500 btu
-
800 btu
-
1050 btu
-
2500 btu
Question 12
Question
what is the approximate heat content of one gallon of No.2 fuel oil?
Answer
-
75,000 to 90,000 btu
-
95,000 to 135,000 btu
-
137,000 to 142,000 btu
-
145,000 to 170,000 btu
Question 13
Question
what is a typical manifold pressure for a natural gas furnace?
Answer
-
3.5 in w.c.
-
11 in w.c.
-
2 psi
-
5 psi
Question 14
Question
what is the typical atmospheric manifold pressure for a propane furnace?
Answer
-
3.5 in w.c.
-
11 in w.c.
-
2 psi
-
5 psi
Question 15
Question
what type of furnace is commonly installed in a closet with underfloor supply ducts?
Answer
-
downflow
-
horizontal
-
lowboy
-
upflow
Question 16
Question
which of the following is required for combustion?
Answer
-
fuel
-
heat
-
oxygen
-
all of the above
Question 17
Question
which of the following is not a product of complete combustion?
Answer
-
carbon dioxide
-
carbon monoxide
-
heat
-
water
Question 18
Question
an unconfined space (in terms of furnace installation) is defined as a space with a volume equal to or greater than _______ per 1,000 btu of input rating
Answer
-
25 ft3
-
50 ft3
-
75 ft3
-
100 ft3
Question 19
Question
combustion air may be added to a confined space by a duct to the outside, sized on an input of 1 in2 per __________.
Answer
-
1000 btu
-
2000 btu
-
4000 btu
-
5000 btu
Question 20
Question
what type of burners are commonly used with induced-draft gas furnaces?
Answer
-
gun style
-
pot style
-
ribbon
-
inshot
Question 21
Question
what is the typical color of a properly burning gas flame?
Question 22
Question
in a gas furnace, primary combustion air is introduced in the ________.
Answer
-
burner prior to ignition
-
burner after ignition
-
gas line
-
heat exchanger
Question 23
Question
a "dumbbell" style CO2 tester ___________.
Answer
-
contains a test fluid that absorbs CO2
-
measures CO2 in parts per million
-
provides a digital readout
-
requires a power supply
Question 24
Question
useful heat output, expressed as a percentage of the total burner input, is known as the ________ of a gas furnace.
Question 25
Question
which type of ignition system uses a thermocouple?
Answer
-
direct ignition
-
hot surface
-
intermittent ignition
-
standing pilot
Question 26
Question
the blower in a standing pilot furnace is generally started by a(n) __________.
Question 27
Question
a furnace with an induced draft fan uses a ________. to prove air flow
Question 28
Question
flame rectification proves flame by creating a signal in response to a ________.
Answer
-
change in resistance
-
current conducted in one direction through the flame
-
temperature activated switch
-
voltage produced by the flame
Question 29
Question
when the output of a furnace matches the heat loss or heat gain of the conditioned space, the system is said to be at its
Answer
-
balanced point
-
design temperature
-
full-load condition
-
reference point
Question 30
Question
residential load calculations should be completed according to ACCA's
Answer
-
manual D
-
Manual J
-
Manual N
-
Manual P
Question 31
Question
when furnaces are installed in attics or crawl spaces, special care must be taken to__________.
Question 32
Question
which of the following is true of low voltage control wiring.
Answer
-
it is exempt from NEC requirments
-
it may not be run in the same conduit as line voltage
-
it may not exceed 100ft in length
-
it must be ran in metal conduit
Question 33
Question
what is the maximum pressure that can be supplied to most natural gas furnaces?
Answer
-
3.5 in W.C.
-
14 in W.C.
-
2 psi
-
5 psi
Question 34
Question
the sensor of an electronic leak detector can be affected by ________. which may cause the instrument to give a false indication of a gas leak
Answer
-
cutting oil
-
moisture
-
pipe sealant
-
teflon tape
Question 35
Question
what is the minimum diameter for condensate drain pipe
Answer
-
1/2 in
-
3/4 in
-
1 in
-
1 1/4 in
Question 36
Question
generally speaking a residential thermostat should be mounted _________.
Question 37
Question
which is the proper terminal for heating on most thermostats
Question 38
Question
on an auto changeover thermostat, the difference between heating and cooling setpoints (that keeps the equipment cycling back and forth between heating and cooling) is know as the ________.
Answer
-
deadband
-
droop
-
offset
-
throttling range
Question 39
Question
in order to prevent condensation from forming in the heat exchanger, the cooling coil should always be mounted ________.
Answer
-
from behind :-)
-
before the heat exchanger
-
below the heat exchanger
-
downstream from the heat exchanger
-
upstream from the heat exchanger
Question 40
Question
in the summer months, the damper on the bypass humidifier should be _________.
Answer
-
fully closed
-
fully open
-
partially open
-
removed
Question 41
Question
which of the following is NOT true of a residential zoned system
Answer
-
each zone has its own temperature control
-
there can be no more then four zones
-
zoned units may use a by pass damper to pass excess supply air back into return air
-
zoned units may use a dump damper to pass excess supply air to a non-critical area
Question 42
Question
a type of equipment that transfers both latent and sensible heat from the exhaust air to the supply air is know as a(n) ________.
Question 43
Question
a standing pilot furnace with an atmospheric burner is an example of a __________ gas appliance
Answer
-
category I
-
category II
-
category III
-
category IV
Question 44
Question
a high efficiency condensing furnace is an example of a _________ gas appliance
Answer
-
category I
-
category II
-
Category III
-
category IV
Question 45
Question
burning of 1 ft3 of natural gas produces __________ of flue gas
Answer
-
1 ft3
-
2 ft3
-
10 ft3
-
11 ft3
Question 46
Question
which of the following affects the venting force in a gravity venting system
Answer
-
the height of the chimney
-
the percentage of CO2 in the flue gas
-
the type of fuel used
-
the type of fuel pipe used
Question 47
Question
a fan is used to pull flue gases through the combustion chamber in a(n) _________ vent system.
Answer
-
forced draft
-
gravity
-
induced draft
-
natural draft
Question 48
Question
how far above the peak of the roof should the chimney extend
Question 49
Question
a horizontal flue vent must have an upward slope of at least _________ per foot of length.
Answer
-
1/8 in
-
1/4 in
-
1/2 in
-
1 in
Question 50
Question
problems related to a shortage or contamination of combustion air are eliminated in a(n) vent system
Answer
-
direct
-
forced draft
-
gravity
-
induced draft
Question 51
Question
when can a masonry chimney be used to vent category IV appliances?
Answer
-
when it is existing chimney
-
when it is no more that one story tall
-
when it is used as a common vent along with a category I appliance
-
Never
Question 52
Question
category IV furnaces are commonly vented with what type of material
Answer
-
single wall metal
-
double wall class B
-
masonry
-
PVC pine
Question 53
Question
when does a category IV vent pipe require insulation?
Question 54
Question
category IV equipment required a condensate drain. a trap must be installed in the drain line to _________.
Answer
-
break the vacuum allowing water to drain
-
keep water from draining to quickly
-
prevent water from freezing
-
provide a seal that prevents the leakage of flue gas