Question 1
Question
An architect is working on the design of an auditorium, located in a school building. Based on the design decision, the auditorium will have recessed light fixtures and unexposed, smooth and flat ceiling. Which of the following smoke detector is the most appropriate option for this project?
Answer
-
Laser Beam Photoelectric Detector
-
Ionization Smoke Detectors
-
Video Smoke Detection
-
Projected Beam Photoelectric Smoke Detector
Question 2
Question
What is the minimum fire rating requirement of the door openings in shaft enclosures?
https://codes.iccsafe.org/content/IBC2018
Answer
-
1/2 hr
-
1 hr
-
1 1/2 hrs
-
2 hrs
Question 3
Question
The partial plan diagram given below belongs to the first floor of a fully sprinklered nursing home with four stories. The occupant load of the first floor is 48 and the corridors in the given diagram below serve all of the occupants, however, they will not be used for stretchers or bed movement for access to care. Based on the given dimensions of the egress components, which of the following dimension does not meet the code requirements?
https://codes.iccsafe.org/content/IBC2018
https://www.flexiquiz.com/Uploads/Questions/s583e87a0-2c6a-4c69-8c68-d2a9cc98be1f_qc07d215e-df46-4192-ac2d-8869a8ed2ac2
Question 4
Question
An architect is designing an office building with self-parking, parking space adjacent to it. The rectangular parking area is 405 feet x 610 feet. The lighting designer recommends the use of HPS light fixtures and estimates a 6300 W, floodlighting level will be provided for the whole parking area. Based on the Lighting Application Guide given below, decide whether the lighting level per square foot achieved in this project is sufficient enough?
https://www.flexiquiz.com/Uploads/Questions/s583e87a0-2c6a-4c69-8c68-d2a9cc98be1f_qd07c7d50-322c-4a0a-9517-e3bbe8d40f71
Answer
-
Yes, it is sufficient. The total floodlighting level should be minimum 4941 W
-
Yes, it is sufficient. The total floodlighting level should be minimum 5682.15 W
-
No, it is not sufficient. The total floodlighting level should be minimum 6423.3 W
-
No, it is not sufficient. The total floodlighting level should be minimum 7411.5 W required.
Question 5
Question
Which of the following is NOT an available method to improve ground soil conditions to increase its density and stability?
Answer
-
Soil-mixing
-
Compaction
-
Pre-consolidation
-
Back-filling
-
Ground Freezing
Question 6
Question
An architect is considering an all-water HVAC system for his client’s new residential project. The client prefers a faster air exchange in the space and doesn’t mind the extra noise that the delivery unit may create. Which of the following water-to-air heat exchanger devices is the best delivery unit to meet these criteria?
Question 7
Question
What is an advantage of solar tubes compared to skylights?
Answer
-
Skylights are more prone to leaking
-
Skylights are prone to thermosiphon
-
Skylights are not applicable on as many types of roofs as solar tub
-
Skylights use less environmentally safe materials
Question 8
Question
An architect is designing a marine structure where concrete columns will be subject to salty water on regular basis. What type of rebar below should be specified for the structural concrete members of this project?
Answer
-
Steel rebars
-
GFRP rebars
-
Epoxy coated rebars
-
Stainless steel rebars
Question 9
Question
What is it called if the underground soils are made of very porous layers of sand, gravel and other permeable materials that can contain large amounts of water and let it flow freely?
Answer
-
Artesian Well
-
Aquifer
-
Water Table
-
Saturated Ground
Question 10
Question
Which of the following structural beam given below potentially has the longest spanning range?
Question 11
Question
What is the hourly fire rating requirement of a firewall in a residential apartment building if the building is Type V construction?
https://codes.iccsafe.org/content/IBC2018
Question 12
Question
Select the correct components that belong to a traction MRL elevator. Check the three that apply.
Answer
-
Hoisting cables
-
Penthouse for motor
-
Hoisting machine
-
Side counterweights
-
Piston
-
Plunger
Question 13
Question
What is the minimum number of means of egress required for a retail store located in a mall, with 78 feet travel distance?
https://codes.iccsafe.org/content/IBC2018
Question 14
Question
A townhouse owner wants to add a toilet and a lavatory in her basement guest room. Which of the following scenarios is more likely to happen after the architect receives this project?
Answer
-
The architect will check local code and inspection requirements and the level of existing public sanitary sewer location and elevation to decide if an ejector pump is required or not.
-
The architect can direct the homeowner to a local plumbing contractor to install the fixtures immediately.
-
The architect can direct the homeowner to install plumbing fixtures by themselves without further inquiry.
-
The architect should call city officials and local code authorities to inquiry for their recommendation on an experienced plumbing contractor to do the job.
Question 15
Question
Which of the following below is not used to transfer lateral loads through the building to the foundations?
Answer
-
Floor diaphragms
-
Rigid cores
-
Curtain walls
-
Trussed floor systems
Question 16
Question
Select all acoustical strategies below that are effective in reducing echoing, especially for front row seaters, in large lecture halls. Check the three that apply.
Answer
-
Provide deep, sound-absorbing glass-fiber blanket insulation supported by furring on the rear wall of the lecture hall
-
Reduce the front portion of the ceiling height that is above the speaker (or the stage) to create a useful reflection surface
-
Splay the rear wall to redirect the echoing sound to more absorbent surfaces such as carpe flooring
-
Provide a uniform ceiling height through out to space, from stage to rear end of the room.
-
Create concave ceilings for large lecture halls to prevent echoing
-
Create a concave rear wall to absorbs echoing sounds
Question 17
Question
Match the tilt angles of solar panels given below, to the most appropriate building scenarios. Drag and drop scenarios accordingly.
Question 18
Question
Among given building diagrams above, select the correct positive and negative wind pressures on windward and leeward sides of the buildings. Check the three that apply.
https://www.flexiquiz.com/Uploads/Questions/s583e87a0-2c6a-4c69-8c68-d2a9cc98be1f_qf9e142af-d757-4b6a-bb78-4332345244ae
Question 19
Question
As per given diagram above which of the following shading device will not provide the best shading design strategy as part of passive solar system design of this building?
https://www.flexiquiz.com/Uploads/Questions/s583e87a0-2c6a-4c69-8c68-d2a9cc98be1f_q922c563b-5227-4d6f-96f9-bb6f69f1b399
Answer
-
Horizontal overhangs on East & West windows
-
Horizontal overhangs on South windows
-
Vertical fins on North windows
-
Vertical slanted fins on South window