Question 1
Question
How many different outputs can an A/M 32A-60 provide?
Question 2
Question
Which item is the only auxiliary power unit (APU) to provide both electrical and pneumatic power?
Answer
-
A/M 32A-60
-
A/M 32A-86
-
A/M 32A-95
-
MC-2A
Question 3
Question
Where is the A/M 32A-60 pneumatic duct hose stored?
Answer
-
On the unit's roof housing
-
In the rear storage compartment
-
In the front storage compartment
-
In the chassis storage compartment
Question 4
Question
Identify the output of the A/M 32A-95
Answer
-
28 VDC
-
Bleed air
-
120 VAC, single-phase, 400 Hz
-
120/208 VAC, three-phase, 400 hz
Question 5
Question
Due to the expansion properties of fuel, an unmodified A/M 32A-95 fuel tank should not be filled more than approximately how full?
Question 6
Question
Which electrical output is supplied by the A/M 32A-86 generator set?
Question 7
Question
How many instruments/control panels must the operator make use of during operation of the A/M 32A-86 generator set?
Question 8
Question
Which panel of the A/M 32A-86 generator set has the circuit breaker to shut off current flow in case of an overload?
Answer
-
Generator control
-
Engine control
-
External AC
-
External DC
Question 9
Question
Which auxiliary power unit serves as an external power source for the MQ-1 and MQ-9 aircraft?
Question 10
Question
Where is the control panel of the starter cart assembly (SCA) located?
Answer
-
Underneath a cover located at the top of the unit
-
On the engine monitoring panel
-
On the power outlet located on the right side of the generator set
-
On the starter cart assembly electronics tray
Question 11
Question
An operator is not required at or in the immediate vicinity of an in-use auxiliary power unit (APU) when they are practicing loading
Answer
-
High explosive munitions
-
Live nuclear weapons
-
Live chemical weapons
-
Inert training munitions
Question 12
Question
Fighter aircraft may be exempted from the 50 foot distance placement requirements of an auxiliary power unit (APU) during
Answer
-
Combat operations only
-
Simulated combat operations only
-
Combat or simulated combat operations
-
Combat, simulated combat, or adverse weather conditions
Question 13
Question
Which area must you void when operating units powered by turbine engines?
Question 14
Question
Which air compressor may be used to per ate small pneumatic tools?
Answer
-
MC-1A
-
MC-2A
-
MD-3
-
A/M 32A-60
Question 15
Question
How much air pressure is produced by the MC-2A air compressor?
Answer
-
5 cfm at 200 psi
-
15 cfm at 200 psi
-
5 cfm at 3200 psi
-
15 cfm at 3200 psi
Question 16
Question
Before you connect or disconnect a high-pressure service hose, you must make sure the system is not
Question 17
Question
Which power output of a portable floodlight set is used for powering common electrically powered hand tools?
Answer
-
28 VDC
-
115-120 VAC
-
220-240 VAC
-
225-300 VAC
Question 18
Question
The FL-1D can serve as a ground power source for MQ-1 and MQ-9 aircraft when used in conjunction with a/an
Question 19
Question
When can you use the floodlight receptacles for external power to operate accessories
Answer
-
When 115-120 VAC is required
-
When 110-115 VAC is required
-
When 235-300 VAC is required
-
Never, these receptacles cannot be used to operate accessories
Question 20
Question
How are flood lights positioned when working around aircraft?
Answer
-
Downwind from the A/C
-
At the end of their power cord
-
50 feet away from the A/C nearest point
-
As far away as possible from the A/C, while still providing adequate lighting
Question 21
Question
In which position must the FL-1D's floodlight platform be placed during towing?
Question 22
Question
Which storage compartment is the A/M 32C-10 duct hoses stored?
Answer
-
Unit's roof housing
-
Rear
-
Front
-
Chassis
Question 23
Question
Which A/M 32C-10 control panel will you use when operating the system?
Question 24
Question
How far from the supported aircraft should the A/M 32C-10 air conditioner be positioned for optimum unit operating efficiency and safety?
Answer
-
8 to 10 feet
-
10 to 12 feet
-
15 to 30 feet
-
50 feet minimum
Question 25
Question
Which per pound per square inch (psi) is the maximum amount of bleed-air pressure that may be applied to the -10 air conditioner?
Answer
-
15 psi
-
25 psi
-
35 psi
-
45 psi
Question 26
Question
How many operators are required to be present during the operation of the -10 air conditioner?
Question 27
Question
Which additional piece of aerospace ground equipment (AGE) is required during the operation of the polyalphaolefin (PAO)/air cooling cart?
Question 28
Question
How many fluid temperature modes are available on the polyalphaolefin (PAO)/air cooling cart?
Question 29
Question
How does the operator initiate the delivery of polyalphaolefin fluid once it has reached proper operating temperature?
Answer
-
By closing the aft restrictor valve
-
By opening the aft restrictor valve
-
By opening the aft restrictor manifold
-
The operator takes no action, the polyalphaolefin (PAO)/air cooling cart begins fluid delivery automatically
Question 30
Question
Which action must be ensured before making or breaking a connection between the polyalphaolefin (PAO)/air cooling cart and the aircraft?
Question 31
Question
The cool-air hatch on the MJ-2A hydraulic test stand is located on the unit, by which location on the unit?
Question 32
Question
Which personnel protective equipment (PPE) must be worn when you operate the MJ-2A?
Answer
-
Goggles
-
Ear protectors
-
Gloves
-
Coveralls
Question 33
Question
Identify the primary reason for making sure aircraft fittings are clean before attaching hydraulic servicing hoses?
Answer
-
Dirty fittings will cause damage to the threads of the connectors on the test stand
-
Dirty fittings can cause an incomplete seal with the hoses resulting in leaks at the attach points
-
Dirty fittings can introduce contaminants to the hydraulic system causing damage to valves and lines
-
Dirt can scour protective coatings off of the fittings that will allow then to corrode when bare metal is subjected to the environment
Question 34
Question
Which aircraft(s) require aircraft armament system personnel to use the self-generating nitrogen servicing cart (SGNSC)?
Answer
-
F-15, F-16, and F-22
-
B-1, B-2, and B-52
-
F-15 and F-15E
-
F-22 only
Question 35
Question
When using the self-generating nitrogen servicing cart (SGNSC) why is it important that waste gasses are not allowed to accumulate in an enclosed space?
Answer
-
Dangerous levels of carbon monoxide can build up displacing space
-
Dangerous levels of carbon dioxide can build up displacing oxygen
-
Excess nitrogen can pose a fire or explosion hazard
-
Excess oxygen can pose a fire or explosion hazard
Question 36
Question
Why is it important to prevent venting the self-generating nitrogen servicing cart (SGNSC) storage tanks in an enclosed space without sufficient ventilation?
Answer
-
Excess nitrogen can pose a fire/explosion hazard
-
Venting of high pressure gas is extremely loud and could damage hearing
-
A dangerous overpressure situation could occur causing harm to personnel and damage to structures
-
Large volumes of nitrogen can displace the oxygen in the air, making it possible for a person to suffocate without warning
Question 37
Question
Which precaution must be taken prior to attempting to loosen fittings, or removing tubes or hoses when using the self-generating nitrogen servicing cart (SGNSC)?
Answer
-
Ensure cart power is off
-
Ensure the entire system is depressurized
-
You must vent the pressure from that part of the system through the appropriate valve
-
Ensure the carts high pressure storage tanks main shutoff valves are in the "NO-FLOW" position
Question 38
Question
the maximum static load the B-1maintenance stand can sustain is
Answer
-
300 pounds
-
400 pounds
-
500 pounds
-
600 pounds
Question 39
Question
Identify the platform height range of the B-4 maintenance stand?
Answer
-
3 to 7 feet
-
4 to 8 feet
-
3 to 10 feet
-
4 to 12 feet
Question 40
Question
The hand pump for raising the B-4 maintenance stand is located on the
Answer
-
Platform near the ladder
-
Remote control unit (RCU)
-
Base of the stand near the aft castors
-
Base of the stand near the forward castors
Question 41
Question
Which maintenance stand is described as a scissors-type, with a variable height platform, and mounted on a long-legged caster-equipment base?
Question 42
Question
Identify the platform height range of the B-5 maintenance stand
Answer
-
1 to 7 feet
-
1 to 10 feet
-
7 to 12 feet
-
7 to 15 feet
Question 43
Question
Which stand can be used independently, or can be installed as an extension on the B-1maintenance stand?
Question 44
Question
The lifting capacity of the davit on the split deck is
Answer
-
200 - 500 pounds
-
250 - 500 pounds
-
300 - 500 pounds
-
350 - 500 pounds
Question 45
Question
If the split-deck maintenance platform's tape switches detect an obstruction during an operation, what will the switches stop on the unit?
Answer
-
Forward drive capacity only
-
Platform extension capability
-
Platform extension and lowering capabilities only
-
Forward drive, platform extension and lowering capabilities
Question 46
Question
During an operator's pre-use inspection of aerospace ground equipment (AGE), what is required by the operator to ensure proper unit operation?
Answer
-
Check the AFTO 781K
-
Check the AGE personnel as the status of the unit
-
Cycle the unit through the capabilities that you will use
-
Cycle the unit completely through its range of capabilities
Question 47
Question
Which AFTO form is used to annotate any defects you may find on your aerospace ground equipment (AGE)?
Answer
-
AFTO Forms 244 and 245
-
AFTO Form 349
-
AFTO Form 350
-
AFTO Form 781A