  1. 1Which one of the following meters has maximum loading effect on the circuit under measurement ?
    1. A1000 Ω/volt
    2. B10 MΩ/volt
    3. C100 Ω/volt
    4. D1 MΩ/volt
  2. 2A 150 V moving iron voltmeter of accuracy class 1.0 reads 75 V when used in a circuit under standard conditions. The maximum possible percentage error in the reading is
    1. A0.5
    2. B1.0
    3. C2.0
    4. D4.0
  3. 3To measures 5 volts, if one selects a 0-100 volt range voltmeter which is accurate with in ± 1%, then the error in this measurement may be up to
    1. A10 %
    2. B20 %
    3. C30 %
    4. D40 %
  4. 4Assertion (A) : It is always desirable to take the reading of an indicating instrument very close to the full scale reading.
    Reason (R) : Accuracy of an indicating instrument is maximum at the full scale deflection and error increases as reading comes closer to the beginning of the scale.
    1. AA is true but R is false
    2. BA is false bur R is true
    3. CBoth A and R are true and R is the correct explanation of A
    4. DBoth A and R are true but R is NOT the correct explanation of A
  5. 5If an ammeter is to be used in place of a voltmeter, we must connect with the ammeter a
    1. AHigh resistance in parallel
    2. BHigh resistance in series
    3. CLow resistance in parallel
    4. DLow resistance in series
  6. 6In eddy current damping system, the disc employed should be of
    1. AConducting and magnetic material
    2. BConducting but non-magnetic material
    3. CMagnetic but non-conducting material
    4. DNon-conducting and non-magnetic material
  7. 7Which of the following can act as in inverse transducer?
    1. ALVDT
    2. BStrain
    3. CPiezo electric crystal
    4. DBimetal strip
  8. 8The total current I = I1 + I2 in a circuit is measured I1 = 150 ± 3A , I2 = 250 ± 4 A, where the limits of error are given as standard deviations. I is measured as
    1. A(400 ± 3) A
    2. B(400 ± 2.24) A
    3. C(400 ±5) A
    4. D(400 ± 1) A
  9. 9A first order instrument is characterized by
    1. AStatic sensitivity and damping coefficient
    2. BTime constant only
    3. CStatic sensitivity and time constant
    4. DStatic sensitivity, damping coefficient and natural frequency of oscillations
  10. 10The ratio of change in output to the change in the input is called
    1. Aprecision
    2. Bresolution
    3. Csensitivity
    4. Drepeatability