Frage 1
Frage
What are the advantages of digital fluoroscopy over conventional fluroscopy?
Frage 2
Frage
Digital fluoroscopy's tube current is measured in hundreds of mA instead of less than [blank_start]5[blank_end] mA, as in image-intensifying fluoroscopy.
Frage 3
Frage
What is interrogation time?
Antworten
-
The time required for the x-ray tube to be switched on and reach selected levels of kilovolt peak (kVp) and mA.
-
The time required for the x-ray tube to be switched off.
-
The fraction of time that the x-ray tube is energized.
Frage 4
Frage
Duty cycle is the time required for the x-ray tube to be switched off.
Frage 5
Frage
Pulse progressive fluoroscopy is [blank_start]reduces[blank_end] patient radiation dose.
Frage 6
Frage
The sensitive component of a CCD is a layer of crystalline silicon.
Frage 7
Frage
[blank_start]Progressive mode[blank_end] produces a sharper image with less flicker than [blank_start]interlaced mode[blank_end].
Antworten
-
Progressive mode
-
Interlaced mode
-
interlaced mode
-
progressive mode
Frage 8
Frage
[blank_start]Mask mode[blank_end]: Method of temporal subtraction that results in successive subtraction images of contrast-filled vessels.
[blank_start]Temporal subtraction[blank_end]: Computer-assisted technique whereby an image obtained at one time is subtracted from an image obtained at a later time.
[blank_start]Hybrid subtraction[blank_end]: Technique that combines two types of subtraction.
[blank_start]Time-interval difference (TID) mode[blank_end]: Technique that produces subtracted images from progressive masks and the frames that follow.
[blank_start]Energy subtraction[blank_end]: Technique that takes advantage of changing contrast media during the time of the examination and require no special demands on the high-voltage generator. Uses two different x-ray beams alternately to provide a subtraction image that results from differences in photoelectric interaction.
Antworten
-
Mask mode
-
Temporal subtraction
-
Hybrid subtraction
-
Time-interval difference (TID) mode
-
Energy subtraction
-
Temporal subtraction
-
Mask mode
-
Hybrid subtraction
-
Time-interval difference (TID) mode
-
Energy subtraction
-
Hybrid subtraction
-
Mask mode
-
Temporal subtraction
-
Time-interval difference (TID) mode
-
Energy subtraction
-
Time-interval difference (TID) mode
-
Mask mode
-
Temporal subtraction
-
Hybrid subtraction
-
Energy subtraction
-
Energy subtraction
-
Mask mode
-
Temporal subtraction
-
Hybrid subtraction
-
Time-interval difference (TID) mode
Frage 9
Frage
[blank_start]Conventional[blank_end] fluoroscopy: Images generated directly from x-ray
[blank_start]Digital[blank_end] fluoroscopy: Images produced by pulse-progressive fluoroscopy
Antworten
-
Conventional
-
Digital
-
Digital
-
Conventional
Frage 10
Frage
In conventional fluoroscopy:
- The input phosphor converts [blank_start]x-rays[blank_end] into light
- [blank_start]Photocathode[blank_end] converts light into electrons
- Output phosphor converts [blank_start]electrons[blank_end] back into light
Antworten
-
x-rays
-
photons
-
electrons
-
Photocathode
-
Image intensifier
-
CCD
-
electrons
-
photons
-
x-rays
Frage 11
Frage
In digital fluoroscopy:
- x-rays are converted to [blank_start]light[blank_end] by a(n) [blank_start]image intensifier[blank_end]
- [blank_start]light[blank_end] is converted to electrical signal by CCD
Antworten
-
light
-
electrons
-
photons
-
energy
-
image intensifier
-
input phosphor
-
output phosphor
-
light
-
x-ray
-
electrons
-
photons